{"product_id":"bently-nevada-169459-01-3500-44m-multimode-prox-velom-i-o-module-with-internal-terminations","title":"Bently Nevada 169459-01 3500\/44M Multimode Prox\/Velom I\/O Module with Internal Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 169459-01\u003c\/strong\u003e is a \u003cstrong\u003evibration monitoring I\/O module\u003c\/strong\u003e designed for \u003cstrong\u003eaeroderivative gas turbine vibration monitoring systems\u003c\/strong\u003e within the 3500 Machinery Protection System. Installed in a full-height rear slot of the 3500 rack, it serves as the rear interface card for the \u003cstrong\u003e3500\/44M\u003c\/strong\u003e Aeroderivative GT Vibration Monitor. The module processes field signals from Proximitor sensors, Velomitors, and accelerometers with a high input impedance. Onboard internal termination headers allow direct wiring connection, accepting contact inputs for machine mode switching to alter alert and danger alarm parameter sets, while sending current outputs through 4 to 20 mA recorder channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates directly into a single full-height rear slot of the 3500 system rack\u003c\/li\u003e\n\u003cli\u003eFeatures internal termination headers with Euro-Style or Push-in-Spring connector options for direct transducer and system wiring\u003c\/li\u003e\n\u003cli\u003eInterfaces with Proximitor sensors, Velomitor sensors, and accelerometers for aeroderivative gas turbine monitoring\u003c\/li\u003e\n\u003cli\u003eSupports multimode machine operation by accepting external mode switching contacts to toggle between up to eight alarm parameter sets\u003c\/li\u003e\n\u003cli\u003eProvides dedicated +4 to +20 mA recorder output channels proportional to overall monitor full-scale values\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAeroderivative gas turbine machinery protection and vibration monitoring\u003c\/li\u003e\n\u003cli\u003eDynamic signal processing for Proximitor, Velomitor, and accelerometer transducer loops\u003c\/li\u003e\n\u003cli\u003eMulti-mode machine operation tracking with automated alarm setpoint switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Option\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/44-07-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e169459-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580434\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style connector header, 8 pin, Green (For I\/O modules with internal terminations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580432\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style connector header, 10 pin, Green (For I\/O modules with internal terminations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00561941\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom and Multimode Prox\/Velom I\/O Module ten-pin connector shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e166M2389\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Header, Push-in-Spring Type (Alternative for PN 00580434)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e166M2388\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Header, Push-in-Spring Type (Alternative for PN 00580432)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer Name\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (a Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Impedance (Prox\/Accel)\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Impedance (Velomitor)\u003c\/td\u003e\n\u003ctd\u003e3.5 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Aeroderivative Sensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/(mm\/s) (100 mV\/(in\/s)), 5.71 mV\/(mm\/s) (145 mV\/(in\/s)), 10.19 mV\/(m\/s2) (100 mV\/g), 2.55 mV\/(m\/s2) (25 mV\/g), or 1.02 mV\/(m\/s2) (10 mV\/g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Supply\u003c\/td\u003e\n\u003ctd\u003e23 Vdc nominal at 43 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA proportional to monitor full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Compliance Range\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Resistance Range\u003c\/td\u003e\n\u003ctd\u003e0 to 600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.3662 uA per bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccuracy (Room Temp)\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25% error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccuracy (Over Temp)\u003c\/td\u003e\n\u003ctd\u003e+\/-0.7% error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpace Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion\u003c\/strong\u003e: Install the module strictly in a full-height rear slot directly behind the associated \u003cstrong\u003e3500\/44M\u003c\/strong\u003e main monitor module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Connect field transducer, recorder, and mode control wiring directly to the internal termination blocks using either Euro-Style or Push-in-Spring connector headers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Configuration\u003c\/strong\u003e: Configure module jumpers according to system channel setup prior to powering up the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard Type\u003c\/th\u003e\n\u003cth\u003eDesignation \/ Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with part 15 of FCC Rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/35\/EU; EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2011\/65\/EU; China RoHS EFUP 15 years per SJ\/T 11364-2024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNV GL rules for classification; ABS Rules for Condition of Classification Part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (cNRTLus - No Barriers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (cNRTLus - With Barriers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic [ia Ga] IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic [ia Ga] IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (W\/ IS Output for Division 1); T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (ATEX\/IECEx - No Barriers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (ATEX\/IECEx - With Barriers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3(1) G Ex nA nC ic [ia Ga] IIC T4 Gc; Ex ec nC ic [ia Ga] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666855522667,"sku":"169459-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-169459-01-multimode-prox-i-o-module-qmqb4cn3op4_25383307-c203-42b2-9be6-091597930ffa.jpg?v=1765449178","url":"https:\/\/www.plcprotech.com\/it\/products\/bently-nevada-169459-01-3500-44m-multimode-prox-velom-i-o-module-with-internal-terminations","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}