{"product_id":"bently-nevada-3300-16-11-01-02-03-02-00-pwa-86739-01-dual-vibration-monitor","title":"Bently Nevada 3300\/16-11-01-02-03-02-00 PWA 86739-01 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/16-11-01-02-03-02-00\u003c\/strong\u003e is a dual vibration monitor for the Bently Nevada 3300 machinery monitoring system. The unit uses the original \u003cstrong\u003ePWA 86739-01\u003c\/strong\u003e main circuit board.\u003c\/p\u003e\n\u003cp\u003eThe monitor continuously measures two independent radial vibration channels, identified as Channel A and Channel B. It also monitors proximity probe gap voltage for each channel.\u003c\/p\u003e\n\u003cp\u003eThis configuration has a vibration full-scale range of \u003cstrong\u003e0 to 100 um peak-to-peak\u003c\/strong\u003e. The transducer input option is designed for 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensors with a \u003cstrong\u003e200 mV\/mil\u003c\/strong\u003e scale factor.\u003c\/p\u003e\n\u003cp\u003eThe unit includes a hermetically sealed alarm relay option and internal safety barriers. Alert and Danger functions provide independent machinery protection setpoints for the monitored channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual-channel radial vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndependent Channel A and Channel B measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe gap voltage monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to 100 um peak-to-peak vibration range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 3300 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 3300 XL 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 7200 5 mm and 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e200 mV\/mil transducer input scale factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHermetically sealed alarm relay configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal safety barrier configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuffered transducer outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlert and Danger alarm functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFirst Out, bypass, self-test, and recorder-output functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOriginal PWA 86739-01 main board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRadial shaft vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft gap and position monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotating machinery protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine and compressor vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery condition monitoring using proximity probe systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of existing 3300\/16 monitors with matching configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16 Dual Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA: Full-scale Range\u003c\/td\u003e\n\u003ctd\u003e11 - 0 to 100 um peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB: Transducer Input\u003c\/td\u003e\n\u003ctd\u003e01 - 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Scale Factor\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC: Alarm Relay\u003c\/td\u003e\n\u003ctd\u003e02 - Hermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD: Agency Approval\u003c\/td\u003e\n\u003ctd\u003e03 - Exact catalog code retained; meaning not defined in supplied Rev. P manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE: Safety Barrier\u003c\/td\u003e\n\u003ctd\u003e02 - Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF: Trip Multiply\u003c\/td\u003e\n\u003ctd\u003e00 - None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-11-01-02-03-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDual Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain PWA\u003c\/td\u003e\n\u003ctd\u003e86739-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWA Version\u003c\/td\u003e\n\u003ctd\u003eOriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eRadial vibration and probe gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Full-scale Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 um peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input\u003c\/td\u003e\n\u003ctd\u003e3300 8 mm, 3300 XL 8 mm, 7200 5 mm and 8 mm Proximitor Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Scale Factor\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay\u003c\/td\u003e\n\u003ctd\u003eHermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier\u003c\/td\u003e\n\u003ctd\u003eInternal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e0 to -10 Vdc, +1 to +5 Vdc, or +4 to +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Outputs\u003c\/td\u003e\n\u003ctd\u003eFront-panel coaxial connectors and rear Signal Input Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMonitor Functions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadial Vibration\u003c\/td\u003e\n\u003ctd\u003eContinuous measurement of shaft dynamic motion for Channels A and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Gap\u003c\/td\u003e\n\u003ctd\u003eDisplays negative DC voltage proportional to probe-to-target gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlert Alarm\u003c\/td\u003e\n\u003ctd\u003eFirst-level vibration alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDanger Alarm\u003c\/td\u003e\n\u003ctd\u003eSecond-level vibration alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirst Out\u003c\/td\u003e\n\u003ctd\u003eIdentifies the first channel entering an alarm state when enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bypass\u003c\/td\u003e\n\u003ctd\u003eRemoves a selected channel from active monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDanger Bypass\u003c\/td\u003e\n\u003ctd\u003eInhibits Danger relay drive during maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Output\u003c\/td\u003e\n\u003ctd\u003eProvides transducer signals for external equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003eProvides output proportional to measured vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-Test\u003c\/td\u003e\n\u003ctd\u003ePower-up, cyclic, and user-invoked diagnostic testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePWA 86739-01 Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e86739-01\u003c\/strong\u003e is the original version of the 3300\/16 main PWA.\u003c\/p\u003e\n\u003cp\u003eIts programmable options are configured through jumpers on the main circuit board. These include First Out, alarm latching, Danger voting, vibration alarm delay, Gap Alarm, recorder clamping, corner frequency, recorder output, gap range, vibration range, transducer input, and Trip Multiply.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the complete catalog number before replacing the installed monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the installed board is PWA 86739-01 before changing jumper settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the Proximitor Sensor type and 200 mV\/mil scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord Alert, Danger, gap, recorder, and bypass settings before removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower down the rack or inhibit rack alarms before removing the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify internal safety barrier wiring before reconnecting field circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck both vibration channels and gap readings after installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm Alert and Danger functions before returning the system to service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePWA 86739-01 uses different jumper locations from later 135305-01 and 140720-01 boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not copy jumper positions from later PWA revisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMatch the full-scale range, transducer input, relay type, safety barrier, and Trip Multiply configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreserve the exact catalog number when sourcing a replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53754505658731,"sku":"3300\/16-11-01-02-03-02-00 86739-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3300-16-11-01-02-03-02-00-86739-01_001_1200x1200_c2ff11b8-49ea-4363-aef1-0c54ba0b54ba.png?v=1787379737","url":"https:\/\/www.plcprotech.com\/it\/products\/bently-nevada-3300-16-11-01-02-03-02-00-pwa-86739-01-dual-vibration-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}