{"product_id":"bently-nevada-3500-65-172103-01-rtd-tc-i-o-module-with-internal-terminations","title":"Bently Nevada 3500\/65 172103-01 RTD\/TC I\/O Module with Internal Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/65 172103-01\u003c\/strong\u003e (PWA 184522-01) is an internal termination rear I\/O module designed for the 3500\/65 16-Channel Temperature Monitor system. Installed in the rear slot of a standard 3500 machinery protection rack, it provides the physical interface for connecting up to 16 resistance temperature detectors (RTDs) or isolated tip thermocouples (TCs). The module processes incoming transducer signals and routes them directly to the main \u003cstrong\u003e3500\/65\u003c\/strong\u003e front monitor for continuous thermal monitoring and setpoint evaluation.\u003c\/p\u003e\n\u003cp\u003eEngineered to support critical industrial machinery protection, the \u003cstrong\u003e172103-01\u003c\/strong\u003e accepts a wide variety of standard sensor types, including 3-wire RTDs, 4-wire RTDs, and Types E, J, K, and T thermocouples. Integrated internal termination headers streamline panel wiring by allowing field sensor leads to attach directly to the module without requiring external termination blocks or intermediate cabling assemblies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Capacity:\u003c\/strong\u003e Supports up to 16 independent RTD or isolated tip thermocouple transducer signals on a single rear I\/O card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Termination Design:\u003c\/strong\u003e Features on-board 20-position terminal headers for direct field wiring, eliminating the need for external termination hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Sensor Compatibility:\u003c\/strong\u003e Accepts 100 ohm Platinum (alpha = 0.00385 and 0.00392), 120 ohm Nickel, and 10 ohm Copper RTDs, as well as Type E, J, K, and T thermocouples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e Includes built-in cold junction compensation sensors for precise thermocouple temperature measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Rack Integration:\u003c\/strong\u003e Connects directly into the rear full-height slot of a standard Bently Nevada 3500 rack interface backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermal monitoring of motor, generator, and turbine bearing temperatures.\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring of gas turbine exhaust gas temperatures (EGT) and compressor discharge temperatures.\u003c\/li\u003e\n\u003cli\u003eGearbox casing, sump, and lube oil temperature monitoring in critical rotating machinery.\u003c\/li\u003e\n\u003cli\u003eProcess temperature integration within 3500 Machinery Protection Systems (MPS).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/65-01-XX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/65 Temperature Monitor with RTD\/Isolated Tip TC I\/O Module with Internal Terminations (172103-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/65-02-XX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/65 Temperature Monitor with RTD\/Isolated Tip TC I\/O Module with External Terminations (172109-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/65-00-XX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/65 Temperature Monitor without I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (a Baker Hughes business)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Monitor Part Number\u003c\/td\u003e\n\u003ctd\u003e3500\/65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Part Number\u003c\/td\u003e\n\u003ctd\u003e172103-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinted Wiring Assembly (PWA)\u003c\/td\u003e\n\u003ctd\u003e184522-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput Capabilities\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Inputs\u003c\/td\u003e\n\u003ctd\u003e1 to 16 RTD or isolated tip TC transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 Mohm for each lead input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eType E (-100 degC to +1000 degC), Type J (0 degC to +760 degC), Type K (0 degC to +1370 degC), Type T (-160 degC to +400 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Types\u003c\/td\u003e\n\u003ctd\u003e100 ohm 3-wire and 4-wire Platinum (alpha = 0.00385 or 0.00392), 120 ohm 3-wire and 4-wire Nickel, 10 ohm 3-wire and 4-wire Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Source Value\u003c\/td\u003e\n\u003ctd\u003e913 microamps +\/- 7 microamps at +25 degC per transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePerformance \u0026amp; Accuracy\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003eStandard Rack: +\/-3 degC at +25 degC (+\/-5.4 degF at +77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation Sensor\u003c\/td\u003e\n\u003ctd\u003e+\/-2 degC at +25 degC (+\/-3.6 degF at +77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental \u0026amp; Physical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e20-Position Terminal Headers\u003c\/td\u003e\n\u003ctd\u003eOn-board internal screw terminals for field RTD and TC signal lead connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Edge Connector\u003c\/td\u003e\n\u003ctd\u003eInterface connector for internal signal pass-through to the front 3500\/65 monitor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the rack power is switched off or follow hot-swap procedures per local plant safety guidelines.\u003c\/li\u003e\n\u003cli\u003eAlign the 172103-01 I\/O module with the rear full-height slot directly behind the corresponding 3500\/65 front monitor.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the rack guide rails until the backplane connectors fully engage.\u003c\/li\u003e\n\u003cli\u003eTighten the top and bottom securing thumb screws to ensure proper chassis grounding.\u003c\/li\u003e\n\u003cli\u003eWire the RTD or TC sensor leads to the internal 20-position terminal headers following the channel assignment diagram in the manual.\u003c\/li\u003e\n\u003cli\u003eVerify signal lead integrity and ensure shield drain wires are properly grounded according to system installation drawings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Compatibility:\u003c\/strong\u003e When replacing an older revision I\/O module with revision 172103-01 Rev F or higher, ensure the front 3500\/65 monitor is updated to the latest compatible firmware version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Update Sequence:\u003c\/strong\u003e You must physically remove the I\/O module from the rack before upgrading the 3500\/65 monitor firmware. Failure to remove the I\/O module during the upgrade will result in an \"I\/O Module Mismatch\" and \"562 ADC Failure\" error in the System Event List.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e Channel types (RTD vs TC), range limits, and alarm setpoints must be configured using 3500 Rack Configuration Software (Version 3.85 or later).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification \/ Standard\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2, EN 61000-6-4, Directive 2014\/30\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, Low Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C Class I, Division 2 (Groups A, B, C, D); ATEX\/IECEx Zone 2 (Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4\/T5 Gc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd\u003eSIL 2 rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaritime Approvals\u003c\/td\u003e\n\u003ctd\u003eDNV GL, ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298625387,"sku":"3500\/65 172103-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-65-172103-01_001_1200x1200_7d2c39ff-5507-4a85-9357-8e200e1e71d2.jpg?v=1787738880","url":"https:\/\/www.plcprotech.com\/it\/products\/bently-nevada-3500-65-172103-01-rtd-tc-i-o-module-with-internal-terminations","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}