{"product_id":"danfoss-080g0294-mmigrs2-canbus-control-panel","title":"Danfoss 080G0294 Pannello di controllo MMIGRS2 CANBUS","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e080G0294 (080G0294)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un'interfaccia remota di visualizzazione e controllo ad alte prestazioni della serie\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanfoss\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMMIGRS2, progettata per la gamma di controllori programmabili MCX. In ambienti industriali complessi, come i sistemi HVAC commerciali, gli impianti di refrigerazione su larga scala e le stazioni di teleriscaldamento, questa unità funge da interfaccia uomo-macchina (HMI) principale. Fornendo la visualizzazione dei dati in tempo reale e la regolazione dei parametri tramite un robusto collegamento di comunicazione CANBUS, la\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMMIGRS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarantisce ai tecnici di mantenere la massima efficienza del sistema, riducendo significativamente i tempi di diagnosi e prevenendo i fermi non pianificati nelle applicazioni di gestione termica mission-critical.\u003c\/p\u003e\n\u003ch3\u003eConfigurazione tecnica\u003c\/h3\u003e\n\u003cp\u003eL'architettura del\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e080G0294\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè incentrata sulla perfetta integrazione con l'ecosistema Danfoss MCX. Utilizzando il protocollo CANBUS (CANopen), consente lo scambio di dati ad alta velocità su lunghe distanze tra il controllore e l'interfaccia utente.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrazione logica:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 ingressi digitali e 1 uscita digitale integrati consentono al pannello di funzionare come nodo di controllo locale, in grado di attivare allarmi o ricevere segnali remoti di avvio\/arresto indipendentemente dagli I\/O integrati nel controllore principale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaccia visiva:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIl display LCD è ottimizzato per la leggibilità in ambienti industriali e fornisce un feedback chiaro sulle variabili di sistema, sui setpoint e sugli allarmi attivi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibilità universale dell'alimentazione:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eL'hardware supporta alimentazioni sia a 24 VAC sia a 24 VDC, offrendo flessibilità per diverse architetture di alimentazione degli armadi di controllo (50\/60 Hz).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammabilità:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn quanto accessorio per controllori programmabili, la sua interfaccia può essere personalizzata utilizzando gli strumenti software Danfoss per soddisfare requisiti applicativi specifici.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaratteristica\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e080G0294\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di componente\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePannello di controllo (MMIGRS2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocollo di comunicazione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCANBUS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensione di alimentazione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VAC \/ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngressi digitali (DI)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 pz.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUscite digitali (DO)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 pz.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequenza\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMetodo di montaggio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMontaggio a pannello\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa -20 a 55 gradi C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso del prodotto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.185 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso di spedizione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti tecniche\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIl 080G0294 è sostituibile a caldo su una rete CANBUS attiva?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSebbene il CANBUS sia robusto, si consiglia di disalimentare il ramo specifico prima di collegare la MMIGRS2, per evitare picchi di tensione o errori sul bus che potrebbero interrompere la comunicazione degli altri nodi della rete.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCome si assegna l'indirizzo alla MMIGRS2 se più pannelli sono collegati allo stesso bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eL'ID del nodo dell'unità deve essere configurato in modo univoco nell'ambiente software MCX. Assicurarsi che la velocità di trasmissione corrisponda a quella del controllore master e che vengano utilizzate resistenze di terminazione adeguate se questo è il dispositivo di fine linea.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la distanza massima del cavo per il collegamento CANBUS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa distanza dipende dalla velocità di trasmissione; tuttavia, per le applicazioni industriali standard, sono raggiungibili distanze fino a 500 metri con cavi a doppino intrecciato schermati di alta qualità, purché venga mantenuta l'integrità del segnale.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuida all'ingegneria e all'installazione\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrità del cablaggio CANBUS:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizzare sempre un cavo a doppino intrecciato schermato per il collegamento CANBUS. La schermatura deve essere messa a terra in un solo punto, in genere presso il controllore principale, per prevenire i loop di massa e proteggere il segnale dati dalle interferenze elettromagnetiche (EMI) generate da VFD o contattori di potenza nelle vicinanze.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSigillatura del pannello:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDurante il montaggio a pannello, assicurarsi che la guarnizione sia posizionata correttamente contro il ritaglio. In ambienti con elevata umidità o contaminanti aerodispersi, è essenziale una tenuta ermetica per impedire l'ingresso di umidità nell'elettronica interna del display LCD, che può causare effetti di \"ghosting\" o guasti logici.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResistenze di terminazione:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSe il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e080G0294\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè l'ultimo nodo della catena fisica della rete, è necessario installare una resistenza di terminazione da 120 Ohm tra i terminali CAN-H e CAN-L per prevenire riflessioni del segnale e corruzione dei dati.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418690411,"sku":"080G0294ÿ","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/080g0294-r4ls4543kwa.png?v=1776136974","url":"https:\/\/www.plcprotech.com\/it\/products\/danfoss-080g0294-mmigrs2-canbus-control-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}