{"product_id":"el3004-beckhoff-4-channel-analog-input-terminal-10-v","title":"EL3004 BECKHOFF Morsetto di ingresso analogico a 4 canali ±10 V","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEL3004 (EL3004)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un terminale di ingresso analogico a 4 canali ad alta densità, progettato per il sistema I\/O EtherCAT e specializzato nell'elaborazione di segnali di tensione bipolari da\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10 V a +10 V\u003c\/strong\u003e. Con una\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erisoluzione di 12 bit\u003c\/strong\u003e, offre una soluzione affidabile ed economica per applicazioni industriali B2B quali il monitoraggio del controllo tramite joystick, il feedback della posizione degli attuatori e la misurazione generale della tensione CC. Grazie alla\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etecnologia single-ended\u003c\/strong\u003e, l'EL3004 integra quattro canali indipendenti in una larghezza ridotta di\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, offrendo un'eccezionale densità I\/O che ottimizza lo spazio nell'armadio di controllo.\u003c\/p\u003e\n\u003ch3\u003eConfigurazione tecnica (analisi approfondita)\u003c\/h3\u003e\n\u003cp\u003eL'\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEL3004\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizza un metodo di conversione multiplexato con un tempo di conversione predefinito di\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0,625 ms\u003c\/strong\u003e. Questo lo rende ideale per le attività di automazione standard in cui non è richiesta una sincronizzazione a velocità ultraelevata (Distributed Clocks). Per mantenere l'integrità del segnale in ambienti rumorosi, il terminale dispone di un\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efiltro hardware da 1 kHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee di filtri\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIR (Finite Impulse Response)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIIR (Infinite Impulse Response)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigurabili via software.\u003c\/p\u003e\n\u003cp\u003eI dati di processo sono presentati in un\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eformato a 16 bit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(segno incluso) per un'integrazione perfetta con le funzioni matematiche del PLC. Inoltre, l'EL3004 include la funzionalità di\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evisualizzazione del sovraccarico\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enei dati di processo, consentendo al controller di identificare immediatamente se l'uscita di tensione di un sensore ha superato l'intervallo misurabile. Il terminale è progettato per un uso industriale gravoso e dispone di\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eisolamento elettrico da 500 V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee certificazione\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATEX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper aree pericolose della Zona 2.\u003c\/p\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDettagli delle specifiche\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEL3004\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBECKHOFF\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumero di ingressi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntervallo del segnale\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 V a +10 V (bipolare)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRisoluzione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 bit (presentazione a 16 bit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResistenza interna\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 130 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequenza del filtro di ingresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTempo di conversione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,625 ms (predefinito, configurabile)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eErrore di misura\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; ±0,3 % (rispetto al fondo scala)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo di corrente (E-bus)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTipicamente 130 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolamento elettrico\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V (E-bus \/ tensione del segnale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa -25 a +60 gradi Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOmologazioni\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti tecniche\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual è il vantaggio del cablaggio \"single-ended\" per l'EL3004?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn una configurazione single-ended, tutti e quattro gli ingressi di tensione condividono un riferimento di massa interno comune. Ciò riduce significativamente la complessità del cablaggio e la larghezza del terminale, consentendo di monitorare quattro segnali diversi con un numero inferiore di punti di connessione, a condizione che i sensori condividano lo stesso potenziale di riferimento.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCome funziona la visualizzazione del sovraccarico?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSe la tensione di ingresso supera l'intervallo di ±10 V (fino alla tensione di tenuta dielettrica massima di 30 V), l'EL3004 imposta un\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebit di sovraccarico\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enell'immagine di processo EtherCAT. Ciò consente alla logica del PLC di attivare immediatamente routine di sicurezza o avvisi HMI, impedendo l'utilizzo di dati errati nei calcoli di controllo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuesto terminale è compatibile con i sensori standard da 0-10 V?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì. Sebbene l'EL3004 sia classificato per ±10 V bipolari, può elaborare facilmente segnali unipolari\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eda 0-10 V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. La risoluzione a 12 bit mapperà semplicemente l'intervallo da 0 a 10 V su una parte della rappresentazione digitale totale.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuida tecnica e all'installazione\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCablaggio per la precisione:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper garantire letture accurate a 12 bit, utilizzare sempre\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecavi schermati\u003c\/strong\u003e. La schermatura del cavo deve essere collegata alla terra funzionale (FE) tramite una barra di schermatura o un morsetto a bassa impedenza il più vicino possibile al terminale, così da ridurre al minimo le interferenze elettromagnetiche (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsiderazioni sulla messa a terra:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epoiché si tratta di un terminale single-ended, assicurarsi che non esistano differenze di potenziale significative tra i punti di massa dei quattro sensori. Grandi differenze di potenziale verso terra possono causare errori di misura o, in casi estremi, danneggiare il terminale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManutenzione:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003el'EL3004 supporta il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecablaggio a innesto della serie ES\u003c\/strong\u003e, consentendo di rimuovere la morsettiera senza scollegare i singoli conduttori dei segnali. Questa caratteristica riduce drasticamente i tempi di fermo durante la manutenzione o l'espansione del segmento I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantaggi tecnici\u003c\/h3\u003e\n\u003cp\u003eL'\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEL3004\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffre un eccellente equilibrio tra densità e capacità diagnostiche. La sua\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelevata resistenza di ingresso (\u0026gt; 130 kΩ)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarantisce un carico minimo sulla sorgente del segnale, preservando la precisione della tensione misurata. La conformità alla norma\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEN 61000-6-2\/4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein materia di compatibilità elettromagnetica garantisce la stabilità del terminale anche in ambienti caratterizzati da elevati disturbi elettrici. Per i costruttori di macchine B2B, la possibilità di attivare il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emonitoraggio dei valori limite\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enell'hardware del terminale alleggerisce il carico di elaborazione della CPU, consentendo un monitoraggio locale più rapido e reattivo delle soglie di tensione critiche.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106699010411,"sku":"EL3004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el3004-vium2p5bnt1.png?v=1776244420","url":"https:\/\/www.plcprotech.com\/it\/products\/el3004-beckhoff-4-channel-analog-input-terminal-10-v","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}