{"product_id":"ge-emerson-ic200mdl650-versamax-discrete-input-module","title":"GE FANUC IC200MDL650 VersaMax 32-Point Discrete Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eGE Fanuc IC200MDL650 is a VersaMax 32-point discrete input module for 24 VDC field signals. The inputs are arranged as four isolated groups of eight, each with its own common. The module sends 32 input bits to the VersaMax CPU or network interface unit (NIU).\u003c\/p\u003e\n\u003cp\u003ePositive-logic wiring is supported across the product family. Negative-logic operation requires IC200MDL650C or a later hardware revision. The base catalog number alone does not confirm the installed revision, so the suffix on the module label must be checked before changing field polarity.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eGeneral Electric \/ GE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCatalog number\u003c\/th\u003e\n\u003ctd\u003eIC200MDL650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDiscrete input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput points\u003c\/th\u003e\n\u003ctd\u003e32, arranged as four groups of eight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModule ID\u003c\/th\u003e\n\u003ctd\u003e80088008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal input voltage\u003c\/th\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput voltage range\u003c\/th\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eON-state voltage\u003c\/th\u003e\n\u003ctd\u003e15 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOFF-state voltage\u003c\/th\u003e\n\u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eON-state current\u003c\/th\u003e\n\u003ctd\u003e2.0 to 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOFF-state current\u003c\/th\u003e\n\u003ctd\u003e0 to 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput impedance\u003c\/th\u003e\n\u003ctd\u003e10 kΩ maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBasic ON\/OFF response\u003c\/th\u003e\n\u003ctd\u003e0.5 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSelectable filter\u003c\/th\u003e\n\u003ctd\u003e0 ms, 1.0 ms default, or 7.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBackplane current\u003c\/th\u003e\n\u003ctd\u003e50 mA maximum at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal module supply\u003c\/th\u003e\n\u003ctd\u003eNone; module electronics are powered from the backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGroup-to-group isolation\u003c\/th\u003e\n\u003ctd\u003e250 VAC continuous; 1,500 VAC for one minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput-to-logic\/frame isolation\u003c\/th\u003e\n\u003ctd\u003e250 VAC continuous; 1,500 VAC for one minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoint-to-point isolation\u003c\/th\u003e\n\u003ctd\u003eNone within a group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWiring and Configuration\u003c\/h3\u003e\n\u003cp\u003eEach eight-point group uses a separate common. A group may be wired for positive logic, or for negative logic when the module is revision C or later. Do not mix the two logic conventions within one group. The green point LEDs show the logic state seen by the module. The OK LED confirms backplane power, not the health of every field circuit.\u003c\/p\u003e\n\u003cp\u003eThe 0.5 ms basic response can be combined with a 0, 1.0 or 7.0 ms software filter. These settings produce nominal total response times of 0.5, 1.5 or 7.5 ms. Record the existing filter setting before replacement because a longer filter can suppress contact bounce but also delays input recognition.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation and Replacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIC200MDL650 mounts on a compatible VersaMax IC200CHS-series carrier. The carrier is not assumed to be included unless the quotation states otherwise.\u003c\/li\u003e\n\u003cli\u003eCheck the label suffix before reusing negative-logic wiring. Revision C or later is required for negative logic.\u003c\/li\u003e\n\u003cli\u003eRecord the four common connections, input polarity, filter time and CPU\/NIU configuration before removing the installed module.\u003c\/li\u003e\n\u003cli\u003eMatch the field device supply and common reference to the selected logic convention. The module does not supply field-device power.\u003c\/li\u003e\n\u003cli\u003eDe-energize field wiring before removing or installing the module unless the site procedure and installed equipment explicitly permit the operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDimensions and Logistics\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct dimensions\u003c\/th\u003e\n\u003ctd\u003e110 × 66.8 × 50 mm (W × H × D), excluding carrier and mating connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate net weight\u003c\/th\u003e\n\u003ctd\u003e0.15 kg; historical spare-part reference, confirm against the supplied revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEstimated package dimensions\u003c\/th\u003e\n\u003ctd\u003e180 × 140 × 100 mm with protective packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e1.0 kg store logistics value; confirm after final packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe package dimensions are an air-freight estimate, not a GE product specification. The warehouse measurement should be used for the final freight quotation.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eOrder code: \u003cstrong\u003eIC200MDL650\u003c\/strong\u003e. Confirm the exact hardware suffix, label condition and carrier requirement before ordering a replacement. The installed product documentation should remain with the maintenance record.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770184425835,"sku":"IC200MDL650","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200mdl650_1200x1200_8603ff40-9e5b-46ae-9886-58ad1320046d.jpg?v=1787737823","url":"https:\/\/www.plcprotech.com\/it\/products\/ge-emerson-ic200mdl650-versamax-discrete-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}