{"product_id":"ge-fanuc-ic693cmm311-series-90-30-communications-co-processor-module","title":"GE Fanuc IC693CMM311 Series 90-30 Communications Co-Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CMM311\u003c\/strong\u003e is a communications coprocessor module designed for Series 90-30 PLC systems to provide expanded serial communication capabilities. It equips compatible controllers with GE Fanuc CCM protocol, Modbus RTU slave protocol, and Series Ninety Protocol (SNP\/SNP-X) connectivity. The module features two built-in 25-pin D-shell female serial interfaces, designated as Port 1 and Port 2. Port 1 supports RS-232 electrical standards, while Port 2 supports RS-232, RS-422, and RS-485 standards. The module operates on the CPU baseplate bus using a 5 VDC voltage source and includes a push-to-restart communication button to re-initiate serial interfaces without power cycling.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates two 25-pin D-shell female serial communication ports on a single module.\u003c\/li\u003e\n\u003cli\u003ePort 1 supports RS-232 applications; Port 2 supports RS-232, RS-422, and RS-485 applications.\u003c\/li\u003e\n\u003cli\u003eSupports GE Fanuc CCM, Modbus RTU slave, SNP, and SNP-X protocol combinations across both ports.\u003c\/li\u003e\n\u003cli\u003eFeatures status LED indicators for MODULE OK, PORT 1, and PORT 2 operational monitoring.\u003c\/li\u003e\n\u003cli\u003eIncludes an onboard hardware push button to re-initiate communication links.\u003c\/li\u003e\n\u003cli\u003eOccupies a single slot on the Series 90-30 CPU baseplate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial serial protocol conversion and data acquisition.\u003c\/li\u003e\n\u003cli\u003eIntegration of Modbus RTU slave field devices into Series 90-30 PLC architectures.\u003c\/li\u003e\n\u003cli\u003eMulti-drop serial communications over RS-485 network topology.\u003c\/li\u003e\n\u003cli\u003eDirect point-to-point RS-232 computer or HMI interfacing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311CAT\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-CAT, Series CAT, Rev CAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311G\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-G, Series G, Rev G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311J\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-J, Series J, Rev J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311K\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-K, Series K, Rev K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311L\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-L, Series L, Rev L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311M\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-M, Series M, Rev M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311N\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-N, Series N, Rev N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311P\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-P, Series P, Rev P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311R\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-R, Series R, Rev R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311S\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-S, Series S, Rev S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311T\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311-T, Series T, Rev T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CMM311X\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311\/X, Series X, Rev X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIC693CMM311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunications Coprocessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Voltage\u003c\/td\u003e\n\u003ctd\u003e+5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e400 mA at 5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Serial Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003e25-pin D-shell, female ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 1 Interface Standard\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 2 Interface Standard\u003c\/td\u003e\n\u003ctd\u003eRS-232 \/ RS-422 \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Transmission Speeds\u003c\/td\u003e\n\u003ctd\u003e300, 600, 1200, 2400, 4800, 9600, 19200 Baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eCCM, Modbus RTU slave, SNP, SNP-X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Devices\u003c\/td\u003e\n\u003ctd\u003eModular GE Series 90-30 CPUs (e.g., 331 and later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded CPU Compatibility\u003c\/td\u003e\n\u003ctd\u003eNot compatible with embedded CPUs (e.g., 311, 313, 323)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Modules per System\u003c\/td\u003e\n\u003ctd\u003eFour (4) modules (CPU models 331 and later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Assignment\u003c\/td\u003e\n\u003ctd\u003eAny slot except CPU slot on CPU baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-assembled Cable\u003c\/td\u003e\n\u003ctd\u003eIC693CBL305 Wye cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eModule OK, PORT1, PORT2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.50 lbs (0.68 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\/Obsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e25-pin D-shell Female\u003c\/td\u003e\n\u003ctd\u003eSingle physical connector housing interface signal connections for both Port 1 and Port 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CBL305 Cable Assembly\u003c\/td\u003e\n\u003ctd\u003eWye cable used to split single 25-pin connector into separate Port 1 and Port 2 cabling links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Location:\u003c\/strong\u003e Mount the module exclusively into a CPU baseplate of a Series 90-30 PLC system. Installation into expansion baseplates or embedded CPU systems is strictly prohibited.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Allocation:\u003c\/strong\u003e Insert the single-slot module into any available option slot within the CPU baseplate, excluding the reserved CPU slot itself.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Connections:\u003c\/strong\u003e Utilize the pre-assembled IC693CBL305 Wye connection cable to split the physical 25-pin D-shell interface into individual wiring runs for Port 1 and Port 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Restrictions:\u003c\/strong\u003e Ensure backplane power budget accommodates the 400 mA current draw at +5VDC prior to system startup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53717368209771,"sku":"IC693CMM311","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC693CMM311_003_1200x1200_b883ee4a-8db5-4471-bb95-c2a2a9a7746e.jpg?v=1786611846","url":"https:\/\/www.plcprotech.com\/it\/products\/ge-fanuc-ic693cmm311-series-90-30-communications-co-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}