{"product_id":"general-electric-ic200mdl329-versamax-discrete-isolated-output-module","title":"General Electric IC200MDL329 VersaMax Discrete Isolated Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200MDL329 is a VersaMax discrete isolated output module designed for industrial automation control systems. This compact module features 8 isolated discrete outputs, providing reliable switching capabilities for 120VAC field loads. Intelligent processing for the module is handled by the system CPU or Network Interface Unit (NIU), ensuring seamless integration within the VersaMax I\/O platform architecture.\u003c\/p\u003e\n\u003cp\u003eAn external 120VAC power supply is required to switch power to the connected loads. The unit incorporates optical isolation between user logic and internal circuitry, along with built-in snubber circuits and metal oxide varistors (MOVs) on each output for enhanced transient protection against inductive load switching.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cstrong\u003e8 Isolated Discrete Outputs:\u003c\/strong\u003e Dedicated output channels designed for 120VAC nominal operation.\n  \u003cstrong\u003eOptical Isolation:\u003c\/strong\u003e Provides robust electrical separation between user inputs, logic circuitry, and frame ground.\n  \u003cstrong\u003eDiagnostic LEDs:\u003c\/strong\u003e Individual green LEDs display the ON\/OFF state of each output point, while a dedicated OK LED indicates the presence of backplane power.\n  \u003cstrong\u003eBuilt-In Protection:\u003c\/strong\u003e Each output channel includes integrated snubbers and MOVs to suppress voltage spikes from inductive loads.\n  \u003cstrong\u003eCompact VersaMax Form Factor:\u003c\/strong\u003e Optimized for DIN-rail mounting and quick carrier installation within modular automation setups.\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete actuator control in manufacturing assembly lines\u003c\/li\u003e\n  \u003cli\u003eAC solenoid valve and relay interfacing\u003c\/li\u003e\n  \u003cli\u003ePackaging and material handling equipment\u003c\/li\u003e\n  \u003cli\u003eProcess control panel integration\u003c\/li\u003e\n  \u003cli\u003eHVAC equipment automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ SKU\u003c\/td\u003e\n      \u003ctd\u003eIC200MDL329\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Platform\u003c\/td\u003e\n      \u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e8 isolated outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule ID Code\u003c\/td\u003e\n      \u003ctd\u003eFFFF8840\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e85 to 132 VAC (47 to 63 Hz), 120 VAC nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Current\u003c\/td\u003e\n      \u003ctd\u003e10 mA minimum per point, 0.5 A maximum per point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n      \u003ctd\u003e5.0 A for one cycle (20 ms maximum)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n      \u003ctd\u003e2.0 V maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Leakage Current\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mA at 132 VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003eLess than 0.5 cycle maximum (On and Off)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n      \u003ctd\u003e70 mA maximum (5V output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation Rating\u003c\/td\u003e\n      \u003ctd\u003e250 VAC continuous, 1500 VAC for 1 minute (user input to logic and frame ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Protection\u003c\/td\u003e\n      \u003ctd\u003eSnubber and MOVs on each output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module mounts onto a standard VersaMax carrier with either two or three rows of terminals. For the IC200MDL329 8-point module, connections A1 through A16 handle output channels and their respective returns. B-row terminals can be utilized for additional bussed connections by installing an optional shorting bar with a maximum current-carrying capacity of 2A per point.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all rack power and external load power supplies are turned off before installing or removing modules in hazardous or non-hazardous locations.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely onto its corresponding VersaMax carrier on a standard DIN rail.\u003c\/li\u003e\n  \u003cli\u003eWhen connecting to inductive loads, the use of external suppression circuits is strongly recommended in addition to internal module protection.\u003c\/li\u003e\n  \u003cli\u003eObserve proper thermal derating guidelines based on ambient operating temperatures and simultaneous active output points.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770261496171,"sku":"IC200MDL329","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200mdl329_1200x1200_026c62e6-9429-4edf-8456-00edce1227b8.jpg?v=1787739762","url":"https:\/\/www.plcprotech.com\/it\/products\/general-electric-ic200mdl329-versamax-discrete-isolated-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}