{"product_id":"hima-f3430-4-channel-relay-module","title":"HIMA F3430 H41q\/H51q 4-Channel Safety Relay Output Module","description":"\u003cp\u003e\u003cstrong\u003eHIMA F3430\u003c\/strong\u003e is a four-channel safety-related relay output module for H41q\/H51q and HIQuad system racks. Each channel uses a normally open relay contact. The module provides galvanic separation between the internal control circuitry and the field-side contacts.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eF3430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eSafety-related relay output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem family\u003c\/th\u003e\n\u003ctd\u003eH41q\/H51q and HIQuad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput channels\u003c\/th\u003e\n\u003ctd\u003e4 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact arrangement\u003c\/th\u003e\n\u003ctd\u003eNormally open, dust-tight contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching voltage\u003c\/th\u003e\n\u003ctd\u003e5–250 V AC or 5–110 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching current\u003c\/th\u003e\n\u003ctd\u003e10 mA to 4 A per contact, subject to voltage and load limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum AC switching capacity\u003c\/th\u003e\n\u003ctd\u003e500 VA at power factor above 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum non-inductive DC capacity\u003c\/th\u003e\n\u003ctd\u003e120 W at 30 V DC; 50 W at 70 V DC; 30 W at 110 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical switching time\u003c\/th\u003e\n\u003ctd\u003eApproximately 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical reset time\u003c\/th\u003e\n\u003ctd\u003eApproximately 6 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpace requirement\u003c\/th\u003e\n\u003ctd\u003e4 TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule current\u003c\/th\u003e\n\u003ctd\u003eLess than 100 mA at 5 V DC; less than 120 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSafety and Load Limits\u003c\/h3\u003e\n\u003cp\u003eHIMA lists F3430 as a SIL 3 relay module. Current HIMA revision documentation also states that F3430 is not certified to EN ISO 13849-1. It must not be assigned to a safety function that requires energization on demand without a project-specific safety review.\u003c\/p\u003e\n\u003cp\u003eThe 4 A contact figure is not a universal field-circuit rating. Voltage, load type, switching frequency and external protection remain part of the calculation. HIMA documentation limits fusing to 2.5 A when the module is used in safety controls. Inductive loads require separate assessment of inrush and suppression.\u003c\/p\u003e\n\u003ch3\u003eReplacement Checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecord the existing F3430 hardware revision and rack slot before removal.\u003c\/li\u003e\n\u003cli\u003eConfirm the four field circuits are wired as normally open relay outputs.\u003c\/li\u003e\n\u003cli\u003eCheck each load against the AC or DC switching-capacity limit, not only the 4 A contact limit.\u003c\/li\u003e\n\u003cli\u003eVerify the mating cable plug, LED indication and terminal numbering against the installed drawing.\u003c\/li\u003e\n\u003cli\u003eReview the proof-test interval and application logic before returning the safety function to service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eF3422, F3330 and F3331 are different output modules. Channel count, output technology, voltage range and wiring must be checked before any substitution.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Freight Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRecorded product dimensions\u003c\/th\u003e\n\u003ctd\u003e20 × 190 × 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecorded net weight\u003c\/th\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEstimated protective package\u003c\/th\u003e\n\u003ctd\u003e260 × 80 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEstimated package volume\u003c\/th\u003e\n\u003ctd\u003e0.00395 m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe product dimensions and weight are retained from the existing PLC ProTech product record. The protective package is an editorial estimate for air-freight planning; warehouse measurement controls the final quotation.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52695385112939,"sku":"F3430","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hima-f3430-4-channel-relay-module-hyd3hyymjqu_bc2be81b-9fce-45cb-8c81-0cb5168a8eec.jpg?v=1766132678","url":"https:\/\/www.plcprotech.com\/it\/products\/hima-f3430-4-channel-relay-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}