{"product_id":"hima-h41q-h51q-b9361-b-9361-assembly-kit","title":"HIMA H41q\/H51q B9361 \/ B 9361 Assembly Kit","description":"\u003cp\u003eThe \u003cstrong\u003eHIMA B 9361\u003c\/strong\u003e is an assembly kit providing an additional 5 V power supply (loadable up to 18 A) for HIMA H51q safety systems. The \u003cstrong\u003eB 9361\u003c\/strong\u003e is utilized when the built-in power supply modules within the central rack are insufficient to supply the 5 V circuits (for example, when current requirement I \u0026gt; 18 A for three power supply modules F 7126 in a redundant control setup). Built around a 19-inch K 1408 central rack (5 units high) with an integrated cable tray, the \u003cstrong\u003eB 9361\u003c\/strong\u003e includes an F 7126 power supply module (24 V \/ 5 V, 10 A), an F 7131 power supply monitoring module, and rear-mounted decoupling, fusing, and fan monitoring units (Z 6011, Z 6012, and Z 6013). High availability is ensured as two out of three power supply modules can maintain the 5 V supply.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt around a 19-inch K 1408 central rack (5 units high, 5U) with integrated cable tray\u003c\/li\u003e\n\u003cli\u003eProvides an additional 5 V power supply loadable up to 18 A for H51q systems\u003c\/li\u003e\n\u003cli\u003eEquipped with 1 x F 7126 power supply module (24 V \/ 5 V DC, 10 A) in base kit\u003c\/li\u003e\n\u003cli\u003eOption to expand with up to 2 x additional F 7126 power supply modules (PS2, PS3) operating with 5 V outputs in parallel\u003c\/li\u003e\n\u003cli\u003eEquipped with 1 x F 7131 power supply monitoring module\u003c\/li\u003e\n\u003cli\u003eIncludes 14 socket connectors for installing standard F-type modules of the HIMA Planar System\u003c\/li\u003e\n\u003cli\u003eRear-mounted Z 6011 modules for decoupling and fusing to feed power supply modules\u003c\/li\u003e\n\u003cli\u003eRear-mounted Z 6012 fan module featuring fan run monitoring and fuse monitoring\u003c\/li\u003e\n\u003cli\u003eRear-mounted Z 6013 modules for decoupling and fusing of supply voltage for Z 6012\u003c\/li\u003e\n\u003cli\u003eRedundant supply availability where 2 out of 3 power supply modules guarantee the 5 V supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional 5 V DC power expansion for HIMA H51q safety control systems\u003c\/li\u003e\n\u003cli\u003eIntegration and housing of HIMA Planar System F-type modules\u003c\/li\u003e\n\u003cli\u003ePower distribution and monitoring in industrial safety instrumentation installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePart \/ Module Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentral Rack\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 5 units high, with integrated cable tray\u003c\/td\u003e\n\u003ctd\u003e1 x K 1408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Module\u003c\/td\u003e\n\u003ctd\u003eDecoupling and fusing to feed power supply modules\u003c\/td\u003e\n\u003ctd\u003e3 x Z 6011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Module\u003c\/td\u003e\n\u003ctd\u003eFan with fan run monitoring and fuse monitoring\u003c\/td\u003e\n\u003ctd\u003e1 x Z 6012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Module\u003c\/td\u003e\n\u003ctd\u003eDecoupling and fusing of supply voltage for Z 6012\u003c\/td\u003e\n\u003ctd\u003e2 x Z 6013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Module\u003c\/td\u003e\n\u003ctd\u003ePower supply module 24 V \/ 5 V, 10 A (PS1)\u003c\/td\u003e\n\u003ctd\u003e1 x F 7126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Module\u003c\/td\u003e\n\u003ctd\u003ePower supply monitoring module\u003c\/td\u003e\n\u003ctd\u003e1 x F 7131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Connectors\u003c\/td\u003e\n\u003ctd\u003eSocket connectors for standard (F type) modules of HIMA Planar System\u003c\/td\u003e\n\u003ctd\u003e14 x Socket connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Module\u003c\/td\u003e\n\u003ctd\u003ePower supply module 24 V \/ 5 V (PS2, PS3)\u003c\/td\u003e\n\u003ctd\u003e2 x F 7126 (Separate order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Modules\u003c\/td\u003e\n\u003ctd\u003eStandard (F type) modules of the HIMA Planar System\u003c\/td\u003e\n\u003ctd\u003e1...14 x F type modules (Separate order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB 9361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHIMA H51q Systems, HIMA Planar System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Dimensions \/ Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK 1408 central rack, 19 inches, 5 units high (5U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional 5 V Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoadable up to 18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Power Supply Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x F 7126 (24 V \/ 5 V DC, 10 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 of 3 F 7126 modules guarantee 5 V supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Fuse Z 6011\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A slow blow (5 x 20 mm, HIMA part no. 57 0174409)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Fuse Z 6013\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 A slow blow (5 x 20 mm, HIMA part no. 57 0174169)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Point\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWire and Connection Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Use\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG.21\/22\/23:2 (L+)\u003c\/td\u003e\n\u003ctd\u003eRD 2.5 mm2, Faston 6.3 x 0.8\u003c\/td\u003e\n\u003ctd\u003emax. 16 A gL\u003c\/td\u003e\n\u003ctd\u003e24 VDC Supply for PS1...PS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG.21\/22\/23:1 (L-)\u003c\/td\u003e\n\u003ctd\u003eBK 2.5 mm2, Faston 6.3 x 0.8\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eReference pole for 24 VDC Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG.2: +5 V\u003c\/td\u003e\n\u003ctd\u003eYE 2 x 2.5 mm2, Faston 6.3 x 0.8 (cross section 6 mm2 for distances \u0026gt; 2 m)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eOutput +5 VDC (Supply I\/O subrack B 9302)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG.3: GND\u003c\/td\u003e\n\u003ctd\u003eGN 2 x 2.5 mm2, Faston 6.3 x 0.8 (cross section 6 mm2 for distances \u0026gt; 2 m)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eOutput GND (Supply I\/O subrack B 9302, to be connected with GND of central rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG.24:2 (L+)\u003c\/td\u003e\n\u003ctd\u003eRD 1.5 mm2, Faston 6.3 x 0.8\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eOutput 24 VDC (Supply fuse monitoring and IO-CON in I\/O subrack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG.25:2 (L+)\u003c\/td\u003e\n\u003ctd\u003eRD 1.5 mm2, Faston 6.3 x 0.8\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eOutput 24 VDC (Supply fuse monitoring and IO-CON in I\/O subrack for 2nd I\/O bus B 5222-2, B 5223-2, B 5232-2, and B 5233-2 only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG.26:4\/5\/6\u003c\/td\u003e\n\u003ctd\u003eGY 0.5 mm2, Faston 2.8 x 0.8\u003c\/td\u003e\n\u003ctd\u003emax. 4 A slow blow\u003c\/td\u003e\n\u003ctd\u003eFloating NO\/NC contact for signalling (fuse and fan monitoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG .4\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eWiring ex works: Feeding L+ (24 V) for power supply module F 7126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG .5\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eWiring ex works: Feeding L- (24 V) for power supply module F 7126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG .26: 2, 3\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eWiring ex works: Power supply for fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG .26: 1\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eWiring ex works: Wire for fuse monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG .1:9-11\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eWiring by customer: Connections for monitoring of power supplies by F 7131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG .21, XG .22, XG .23\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eWiring by customer: Connections for Z 6011 (decoupling and fusing to feed power supply modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXG .24, XG .25\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eWiring by customer: Connections for Z 6013 (decoupling and fusing of supply voltage for Z 6012 and feeding of coupling module F 7553 in I\/O subrack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarthing:\u003c\/strong\u003e Installation of the assembly kit requires a conductive connection to the frame or a separate earth connection installed according to EMC requirements. Connection PE earth uses Faston 6.3 x 0.8 mm. Pay strict attention to manufacturer recommendations when detaching and replugging Faston connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 V Circuit Connection:\u003c\/strong\u003e The 5 V circuits of power supply modules in the central rack and in the additional power supply should not be switched in parallel; however, the GND of both power supplies must be connected together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 V Output Wiring:\u003c\/strong\u003e For distances greater than 2 m between the 5 VDC output (XG.2 \/ XG.3) and the I\/O subrack (B 9302), use a wire cross section of 6 mm2 instead of 2.5 mm2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":53718603235691,"sku":"B9361","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/HIMA-B9361_1200x1200_7e1b56de-13c3-4535-974a-d64e288da15f.jpg?v=1786629558","url":"https:\/\/www.plcprotech.com\/it\/products\/hima-h41q-h51q-b9361-b-9361-assembly-kit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}