{"product_id":"honeywell-10018-2-u-22702-fsc-smm-communication-module","title":"Honeywell 10018\/2\/U 22702 FSC-SMM Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e10018\/2\/U 22702\u003c\/strong\u003e is an \u003cstrong\u003eFSC-SMM communication module\u003c\/strong\u003e installed in the Central Part of the Honeywell \u003cstrong\u003eFail Safe Control (FSC)\u003c\/strong\u003e system. It provides communication between the FSC system and the Honeywell \u003cstrong\u003eTotalPlant Solution (TPS)\u003c\/strong\u003e System through the \u003cstrong\u003eUniversal Control Network (UCN)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module contains a Motorola 68360 Quad Integrated Communication Controller operating at 25 MHz. Its architecture includes dedicated flash memory, battery-backed local RAM, and shared RAM for communication with the FSC control processor. A Motorola 68824 token bus controller and Motorola 68194 carrierband modem support the UCN communication function.\u003c\/p\u003e\n\u003cp\u003eAn isolated redundant communication link connects the FSC system to TPS through front connections A and B. After power-up, the application program is automatically downloaded from the FSC control processor into local RAM.\u003c\/p\u003e\n\u003cp\u003eThe module can operate as COM1, COM2, COM3, or COM4. The required COM position is configured through board jumpers J1 and J2.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides FSC-to-TPS communication through the Universal Control Network.\u003c\/li\u003e\n\u003cli\u003eSupports an isolated redundant communication link.\u003c\/li\u003e\n\u003cli\u003eUses separate front connections for communication channels A and B.\u003c\/li\u003e\n\u003cli\u003eAutomatically loads the application program from the FSC control processor after power-up.\u003c\/li\u003e\n\u003cli\u003eSupports COM1, COM2, COM3, or COM4 configuration through jumpers J1 and J2.\u003c\/li\u003e\n\u003cli\u003eProvides a red\/green STATUS LED for module and UCN operating status.\u003c\/li\u003e\n\u003cli\u003eProvides Tx indication during data transmission.\u003c\/li\u003e\n\u003cli\u003eIndicates primary node status in redundant configurations.\u003c\/li\u003e\n\u003cli\u003eIndicates whether communication channel A or B is active.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication between Honeywell FSC systems and TotalPlant Solution systems.\u003c\/li\u003e\n\u003cli\u003eUniversal Control Network communication in FSC installations.\u003c\/li\u003e\n\u003cli\u003eRedundant FSC-to-TPS communication configurations.\u003c\/li\u003e\n\u003cli\u003eCentral Part communication within Honeywell FSC system architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel + Suffix\u003c\/th\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10018\/2\/U 22702\u003c\/td\u003e\n\u003ctd\u003e3400284\u003c\/td\u003e\n\u003ctd\u003eFSC-SMM Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe manual identifies \u003cstrong\u003e10018\/2\/U 22702\u003c\/strong\u003e with part number \u003cstrong\u003e3400284\u003c\/strong\u003e. It also identifies this version as the replacement for the earlier 10008\/2\/U FSC-SMM.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Number\u003c\/td\u003e\n\u003ctd\u003e10018\/2\/U 22702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFSC-SMM Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Location\u003c\/td\u003e\n\u003ctd\u003eFSC Central Part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFSC Software Version\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirements\u003c\/td\u003e\n\u003ctd\u003e8 TE, 3 HE (= 8 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Controller\u003c\/td\u003e\n\u003ctd\u003eMotorola 68360 Quad Integrated Communication Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Clock\u003c\/td\u003e\n\u003ctd\u003e25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eToken Bus Controller\u003c\/td\u003e\n\u003ctd\u003eMotorola 68824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eToken Bus Controller Clock\u003c\/td\u003e\n\u003ctd\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrierband Modem\u003c\/td\u003e\n\u003ctd\u003eMotorola 68194\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e4 Mbit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal RAM\u003c\/td\u003e\n\u003ctd\u003e16 Mbit with parity, battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared RAM\u003c\/td\u003e\n\u003ctd\u003e2 Mbit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnected System\u003c\/td\u003e\n\u003ctd\u003eHoneywell TotalPlant Solution (TPS) System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eUniversal Control Network (UCN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Link\u003c\/td\u003e\n\u003ctd\u003eIsolated redundant communication link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e5 Vdc, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Content\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 mV p-p\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eModules with suffix code 22701 and higher contain minor motherboard changes intended to improve reliability. The 22702 version includes additional motherboard changes associated with component updates. Honeywell states that these changes do not affect module functionality.\u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector or Setting\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection A\u003c\/td\u003e\n\u003ctd\u003eRedundant TPS communication channel A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection B\u003c\/td\u003e\n\u003ctd\u003eRedundant TPS communication channel B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop Front Connector\u003c\/td\u003e\n\u003ctd\u003eConnected to cable A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBottom Front Connector\u003c\/td\u003e\n\u003ctd\u003eConnected to cable B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ1 and J2\u003c\/td\u003e\n\u003ctd\u003eSelect COM1, COM2, COM3, or COM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentral Part System Bus Jumper\u003c\/td\u003e\n\u003ctd\u003eMust be opened for the communication module position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe applicable system bus may be the 7-SBUS, 12-SBUS, or 17-SBUS.\u003c\/p\u003e\n\u003ch3\u003eLED Indicators\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIndicator\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTATUS Off\u003c\/td\u003e\n\u003ctd\u003e5 Vdc power on the FSC Central Part system bus is down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTATUS Red\u003c\/td\u003e\n\u003ctd\u003eModule is offnet or alive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTATUS Green\u003c\/td\u003e\n\u003ctd\u003eUCN program is running, idle or OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTATUS Red\/Green Flashing\u003c\/td\u003e\n\u003ctd\u003eUCN program has failed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTx\u003c\/td\u003e\n\u003ctd\u003eData is being transmitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP\u003c\/td\u003e\n\u003ctd\u003eNode is primary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eChannel A is active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eChannel B is active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFor a non-redundant node, the P LED remains off.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the Central Part of the FSC system.\u003c\/li\u003e\n\u003cli\u003eSet the required COM number with jumpers J1 and J2.\u003c\/li\u003e\n\u003cli\u003eConfigure the module for COM1, COM2, COM3, or COM4 as required.\u003c\/li\u003e\n\u003cli\u003eOpen the corresponding jumper on the 7-SBUS, 12-SBUS, or 17-SBUS.\u003c\/li\u003e\n\u003cli\u003eUse both screws on the left module front section to meet CE requirements.\u003c\/li\u003e\n\u003cli\u003eDo not remove or replace the module while power to the Central Part is on.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApproval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe 10018\/2\/U module data sheet explicitly lists CE, UL, and TUV approvals.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679425851755,"sku":"10018\/2\/U","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/10018-2-U_001_1200x1200_ace9d514-a85c-4c2b-846a-b0448e16bfd6.jpg?v=1786156635","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-10018-2-u-22702-fsc-smm-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}