{"product_id":"honeywell-8c-pcnt03-51454363-375-series-8-c300-controller-processor-module","title":"Honeywell 8C-PCNT03 51454363-375 Serie 8 Modulo processore del controller C300","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-PCNT03\u003c\/strong\u003e (Part Number \u003cstrong\u003e51454363-375\u003c\/strong\u003e) is a \u003cstrong\u003eC300 Controller Processor Module\u003c\/strong\u003e designed for real-time control strategy execution, batch processing, and process field management within the Honeywell Experion PKS Series 8 DCS architecture. Operating on the C300v3 hardware platform, this single-core controller unit executes deterministic control logic via Honeywell Control Execution Environment (CEE) software.\u003c\/p\u003e\n\u003cp\u003eBuilt for heavy-duty industrial process environments, the \u003cstrong\u003eHoneywell 8C-PCNT03 51454363-375\u003c\/strong\u003e features conformal coating on its circuit assembly to prevent corrosion from airborne contaminants, high humidity, and chemical exposure. The unit provides dedicated processing resources and high-capacity communication handling across standard Fault Tolerant Ethernet (FTE) control networks.\u003c\/p\u003e\n\u003cp\u003eThe controller module hosts 18 MB of CEE user memory and supports up to 4 Peer Gateway Module (PGM) network connections. It integrates directly into standard Series 8 carrier assemblies, interfacing with local I\/O modules and peer controllers across distributed process networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Execution Resource\u003c\/strong\u003e: Delivers 5500 processing execution units (Us) available for CPU consumption in loop execution and logic processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated CEE Memory\u003c\/strong\u003e: Equipped with 18 MB of CEE user memory dedicated to strategy configuration, continuous control blocks, and sequential operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Core Architecture\u003c\/strong\u003e: Utilizes a single-core processor engine optimized for deterministic cycle execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Release Compatibility\u003c\/strong\u003e: Supported across Experion PKS software releases R110, R120, R500, R510, and R520.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Backup Architecture\u003c\/strong\u003e: Interfaces with the 51454475-100 RAM charger module to ensure non-volatile program retention during main power failure events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePGM Network Expansion\u003c\/strong\u003e: Supports up to 4 Peer Gateway Module (PGM) connections per C300 controller node.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Access Throughput\u003c\/strong\u003e: Provides a conventional overall data access response rate of 2500 PPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubscribed Parameter Capacity\u003c\/strong\u003e: Handles up to 4000 total subscribed parameters for display data access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeer-to-Peer Publishing\u003c\/strong\u003e: Supports peer-to-peer initiator pull\/get and target publish rates up to 1000 PPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Protection\u003c\/strong\u003e: Features factory conformal coating (coated 1, 3, 4) to withstand harsh ambient atmospheric environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Process Control\u003c\/strong\u003e: Primary processing engine for continuous process loops in chemical, refining, and energy production plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExperion PKS Automation\u003c\/strong\u003e: Control engine executing CEE control strategies, function blocks, and process interlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatch Automation\u003c\/strong\u003e: Sequence execution and recipe execution in pharmaceutical and specialty chemical manufacturing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubsystem Interface Control\u003c\/strong\u003e: Orchestration of field I\/O modules, serial interfaces, and peer controller data exchanges over FTE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454363-375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Designation\u003c\/td\u003e\n\u003ctd\u003eSeries 8 C300 Controller Processor Module (C300v3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Charger Module\u003c\/td\u003e\n\u003ctd\u003e51454475-100 (Required for RAM backup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Protection\u003c\/td\u003e\n\u003ctd\u003eFactory Conformal Coating (Coated 1, 3, 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454363-375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eC300 Controller Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Platform\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Generation\u003c\/td\u003e\n\u003ctd\u003eC300v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Execution Units\u003c\/td\u003e\n\u003ctd\u003e5500 Us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eSingle Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEE User Memory\u003c\/td\u003e\n\u003ctd\u003e18 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Backup Charger Module\u003c\/td\u003e\n\u003ctd\u003e51454475-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Experion Software Releases\u003c\/td\u003e\n\u003ctd\u003eExperion R110, R120, R500, R510, R520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PGM Connections per C300\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Data Access Response Rate\u003c\/td\u003e\n\u003ctd\u003e2500 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Data Access Capacity\u003c\/td\u003e\n\u003ctd\u003e4000 total subscribed parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeer Initiator Pull\/Get Rate\u003c\/td\u003e\n\u003ctd\u003e1000 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeer Target Publish Rate\u003c\/td\u003e\n\u003ctd\u003e1000 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeer-to-Peer Execution Capacity\u003c\/td\u003e\n\u003ctd\u003e100 @ 100 ms, 200 @ 200 ms, 500 @ 500 ms, 1000 @ 1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Assembly Surface\u003c\/td\u003e\n\u003ctd\u003eConformal Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Base Connection\u003c\/td\u003e\n\u003ctd\u003eDual-connector interface for Series 8 carrier backplane attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower and Network Bus\u003c\/td\u003e\n\u003ctd\u003eInternal backplane connection to FTE network bridges and system power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Module Port\u003c\/td\u003e\n\u003ctd\u003eDedicated header connection for the 51454475-100 RAM charger unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the 8C-PCNT03 module and carrier base for physical cleanliness prior to mounting.\u003c\/li\u003e\n\u003cli\u003eEnsure system power supplies to the target Series 8 mounting carrier are isolated or properly configured according to plant safety practices.\u003c\/li\u003e\n\u003cli\u003eAlign the rear edge connectors of the 8C-PCNT03 module with the dedicated controller slot on the Series 8 carrier assembly.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly into place until the locking mechanism engages securely with the carrier.\u003c\/li\u003e\n\u003cli\u003eConnect the 51454475-100 RAM charger module to its designated backup terminal on the controller assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm properly grounded carrier shielding and verify FTE Ethernet cabling connection to network switches.\u003c\/li\u003e\n\u003cli\u003eApply power and verify system LED status indicators proceed through initial boot diagnostic routines.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement Guidelines\u003c\/h3\u003e\n\u003ch4\u003eConfiguration Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse Honeywell Control Builder within a compatible Experion PKS release (R110, R120, R500, R510, or R520) to define CEE control execution strategies.\u003c\/li\u003e\n\u003cli\u003eAssign proper FTE node addressing and controller memory allocations prior to downloading parameter files.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommissioning Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify communication throughput to connected I\/O channels and peer controllers.\u003c\/li\u003e\n\u003cli\u003eMonitor memory consumption metrics to ensure strategy size fits within the 18 MB CEE user memory limit.\u003c\/li\u003e\n\u003cli\u003eConfirm RAM charger module charging voltage and backup functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eReplacement Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Generational Redundancy Constraint\u003c\/strong\u003e: The 8C-PCNT03 (C300v3) module cannot be paired with an 8C-PCNT05 (C300v5) module in a redundant set, as cross-generational hardware will not synchronize redundancy states.\u003c\/li\u003e\n\u003cli\u003eWhen replacing an existing 8C-PCNT03 module, upload and back up current controller databases and parameter settings in Control Builder prior to removing the hardware unit.\u003c\/li\u003e\n\u003cli\u003eVerify that replacement units retain the 51454475-100 RAM charger module specification to prevent memory loss during power cycles.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668000665963,"sku":"8C-PCNT03 51454363-375","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-pcnt03-51454363-375-series-8-c300-controller-j1hvetizyiv_5b36e41d-9839-42e6-aee9-0f34bbe8a9b7.jpg?v=1765504998","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-8c-pcnt03-51454363-375-series-8-c300-controller-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}