{"product_id":"honeywell-cc-ppix01-51410089-175-experion-series-c-pulse-input-module","title":"Honeywell CC-PPIX01 51410089-175 Experion Series C Pulse Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PPIX01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51410089-175\u003c\/strong\u003e) is an 8-channel Pulse Input Module (PIM) designed for the \u003cstrong\u003eHoneywell Experion Series C\u003c\/strong\u003e process automation system. Operating as an I\/O module (IOM) within the C300 Controller architecture, it connects via the Series C IOLINK to provide discrete frequency processing, pulse counting, and speed measurement across industrial process control loops.\u003c\/p\u003e\n\u003cp\u003eFeaturing factory conformally coated circuit boards (indicated by the CC prefix), the \u003cstrong\u003eHoneywell CC-PPIX01\u003c\/strong\u003e provides enhanced protection against harsh atmospheric contaminants, corrosive environments, and industrial moisture. The module acts as a direct hardware bridge for high-speed pulse signals, translating raw field frequency data into structured control variables for totalization, flow monitoring, rotational speed detection, and turbine metering applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries C Architecture Integration:\u003c\/strong\u003e Functions as a dedicated 8-channel Pulse Input Module on the Series C IOLINK bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Features factory-applied conformal coating for durable performance in harsh or corrosive process environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-Channel Capacity:\u003c\/strong\u003e Supports up to 8 pulse input processing channels for frequency, speed, and counter monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Board Firmware Management:\u003c\/strong\u003e Integrates with the Series C IOLINK framework to allow executable image programming and updates over the IOLINK connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis-less Module Form Factor:\u003c\/strong\u003e Directly mounts onto matching Series C Input Output Termination Assemblies (IOTAs) for clean cabinet wiring and minimal footprint.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine and Positive Displacement Metering:\u003c\/strong\u003e Processing frequency and pulse train outputs from liquid and gas flowmeters for accurate volume totalization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotational Speed Monitoring:\u003c\/strong\u003e Interface point for pulse tachometers, proximity switches, and speed sensors monitoring motors, turbines, and rotating machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatch Counting and Dosing Systems:\u003c\/strong\u003e Tracking discrete pulse counts for exact volume control, filling, and batching process loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlant-Wide Flow and Frequency Totalization:\u003c\/strong\u003e Providing high-precision frequency input data to C300 Controller strategies in refining, power generation, and chemical processing plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PPIX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51410089-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePulse Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion Series C \/ C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Block Name\u003c\/td\u003e\n\u003ctd\u003ePIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquivalent PMIO Type\u003c\/td\u003e\n\u003ctd\u003ePI IOP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating Type\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (CC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eSeries C IOLINK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOTA Header Connector\u003c\/td\u003e\n\u003ctd\u003eMulti-pin interface connecting the module to the matching Series C Input Output Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOLINK Communication Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant bus connector for communication with C300 Controllers and firmware loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify the part number (\u003cstrong\u003e51410089-175\u003c\/strong\u003e) and inspect the module circuit board assembly and interface pins for any shipping damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Verification:\u003c\/strong\u003e Ensure system 24 VDC power and IOLINK bus power to the target Series C IOTA slot are within specification before seating the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Alignment:\u003c\/strong\u003e Align the guide features on the \u003cstrong\u003eCC-PPIX01\u003c\/strong\u003e housing with the corresponding slot on the mounting IOTA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsertion and Engagement:\u003c\/strong\u003e Firmly press the module onto the IOTA header until the mounting latches fully engage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Shielding Check:\u003c\/strong\u003e Confirm that pulse sensor field wiring and cable shields are grounded according to recommended instrument grounding practices.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Strategy Configuration:\u003c\/strong\u003e Configure the \u003cstrong\u003eCC-PPIX01\u003c\/strong\u003e module block (PIM) in the Experion PKS Control Builder, assigning channel parameters, scaling factors, and engineering units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOLINK Bus Verification:\u003c\/strong\u003e Check that the C300 Controller recognizes the \u003cstrong\u003eCC-PPIX01\u003c\/strong\u003e on the active Series C IOLINK bus and verify communication status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Consistency:\u003c\/strong\u003e Verify firmware version compatibility via Experion PKS before commissioning, utilizing IOLINK online delivery if reprogramming is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Calibration Check:\u003c\/strong\u003e Apply known frequency or pulse train test signals to each active channel to verify accuracy and totalization parameters before system cutover.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668037759339,"sku":"CC-PPIX01 51410089-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-ppix01-51410089-175-pulse-input-module-ybd3mja4vct_e81c7b88-f2c9-4f65-9dd8-f4e615521738.jpg?v=1765505402","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-cc-ppix01-51410089-175-experion-series-c-pulse-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}