{"product_id":"honeywell-cc-sdor01-51308380-175-experion-series-c-digital-output-relay-extension-module","title":"Honeywell CC-SDOR01 51308380-175 Experion Series C Digital Output Relay Extension Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-SDOR01 (Part Number: 51308380-175)\u003c\/strong\u003e is a Digital Output Relay Extension Module engineered for the Experion Series C architecture. Designed to expand output contact capabilities, the module works in conjunction with the \u003cstrong\u003eCC-PDOB01\u003c\/strong\u003e Digital Output Input Output Module (IOM) and the corresponding \u003cstrong\u003eCC-TDOR01\u003c\/strong\u003e or \u003cstrong\u003eCC-TDOR11\u003c\/strong\u003e Relay Input Output Termination Assemblies (IOTAs). By interfacing with the 24 VDC bussed digital output driver electronics, the CC-SDOR01 allows process control systems to drive discrete high-power or low-power loads through isolated dry contact circuits.\u003c\/p\u003e\n\u003cp\u003eBuilt with a 12-inch footprint, the \u003cstrong\u003eHoneywell CC-SDOR01\u003c\/strong\u003e extension assembly provides 32 isolated relay channels that accept user-configured Form-A (SPST\/NO) or Form-B (SPST\/NC) field contact arrangements via jumper settings. This extension board eliminates the need for external interposing relay panels, providing direct dry contact isolation between control logic and field machinery. Each output channel is equipped with socketed relays, LED status indication, and integrated counter-EMF snubbing networks to protect against inductive switching transients.\u003c\/p\u003e\n\u003cp\u003eOperating within the Series C physical layout, the \u003cstrong\u003eCC-SDOR01\u003c\/strong\u003e features vertical mounting, a tilted thermal dissipation design, and detachable two-level field terminal blocks. The module accepts field wiring up to 12 AWG (2.5 mm sq stranded wire) and maintains galvanic isolation of 1500 VAC RMS or +\/-1500 VDC between individual channels and system logic common.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Isolated Relay Channels:\u003c\/strong\u003e Provides 32 dry contact outputs for high-voltage, high-current, or low-voltage switching tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Contact Operation:\u003c\/strong\u003e Supports Form-A (Normally Open) or Form-B (Normally Closed) contact configurations selected via jumpers on a per-channel basis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Switching Capacity:\u003c\/strong\u003e Accommodates steady-state load currents up to 3 A at 250 VAC RMS or 30 VDC, and inrush currents up to 10 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocketed Relay Design:\u003c\/strong\u003e Individual socketed relays allow straightforward field maintenance and channel replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Transient Suppression:\u003c\/strong\u003e Integrated counter-EMF snubbing circuits (120 Ohm + 0.033 uF) protect contacts from inductive kickback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Offers 1500 VAC RMS or +\/-1500 VDC isolation between channels and system logic common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e Dedicated LED indicators per channel display active output status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable Terminal Blocks:\u003c\/strong\u003e Accepts up to 12 AWG \/ 2.5 mm sq stranded wiring to simplify field landing and cabinet maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterposing Relay Isolation:\u003c\/strong\u003e Direct switching of high-voltage field devices, solenoids, and motor starters without external interposing relay racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Process Control:\u003c\/strong\u003e Interfacing Experion C300 control logic with pumps, valves, fans, and annunciator panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety System Interfacing:\u003c\/strong\u003e Providing volt-free contact signals to third-party safety shutdown systems, motor control centers (MCC), and package units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed Voltage Load Control:\u003c\/strong\u003e Driving combinations of 24 VDC, 120 VAC, and 230 VAC field circuits from a single output assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eExperion Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-SDOR01 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWA\u003c\/td\u003e\n\u003ctd\u003e51308380-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Extension Module \/ Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated IOM Model\u003c\/td\u003e\n\u003ctd\u003eCC-PDOB01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated IOTA Models\u003c\/td\u003e\n\u003ctd\u003eCC-TDOR01, CC-TDOR11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Size\u003c\/td\u003e\n\u003ctd\u003e12 inches (304 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOutput Capabilities\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Form\u003c\/td\u003e\n\u003ctd\u003eForm-A (SPST\/NO) or Form-B (SPST\/NC), jumper selectable per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eAgSnO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC RMS \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current (Max)\u003c\/td\u003e\n\u003ctd\u003e10 A for 4 s at 10% duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-On Time\u003c\/td\u003e\n\u003ctd\u003e20 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-Off Time\u003c\/td\u003e\n\u003ctd\u003e20 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eLoad Ratings (Resistive \u0026amp; Inductive)\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Rating (250 VAC \/ 125 VAC Resistive)\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Rating (30 VDC Resistive)\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Rating (48 VDC Resistive)\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Rating (125 VDC Resistive)\u003c\/td\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Rating (125\/250 VAC, PF = 0.4)\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Rating (30 VAC, L\/R = 100 ms)\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Rating (48 VAC, L\/R = 100 ms)\u003c\/td\u003e\n\u003ctd\u003e0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Rating (125 VAC, L\/R = 100 ms)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eIsolation \u0026amp; Protection\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS or +\/-1500 VDC (channel-to-channel and channel-to-logic common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Surge Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated RC snubber network (120 Ohm + 0.033 uF per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Contact Life\u003c\/td\u003e\n\u003ctd\u003e5,000,000 cycles (at 180 cycles\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Contact Life\u003c\/td\u003e\n\u003ctd\u003e50,000 cycles at 6 A (at 6 cycles\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eWiring \u0026amp; Physical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminal Wire Size\u003c\/td\u003e\n\u003ctd\u003eUp to 12 AWG (2.5 mm sq stranded wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eChannel ON LED indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Pre-Installation Verification:\u003c\/strong\u003e Disconnect system logic power and field excitation power sources prior to mounting or servicing the module. Verify that load voltage and current ratings fall within specified thresholds (12 VDC to 250 VAC RMS).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the CC-SDOR01 extension assembly vertically onto the cabinet carrier channels. Maintain proper vertical clearance to allow heat dissipation via natural convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterconnection Setup:\u003c\/strong\u003e Connect the extension assembly to the primary Digital Output Relay IOTA (CC-TDOR01 or CC-TDOR11) housing the CC-PDOB01 IOM using the dedicated system ribbon cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Contact Configuration:\u003c\/strong\u003e Set the channel jumper headers for each of the 32 outputs to select either Form-A (Normally Open) or Form-B (Normally Closed) dry contact functionality based on control loop requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Termination:\u003c\/strong\u003e Strip field conductor ends and secure them into the detachable terminal blocks. Ensure wire gauges do not exceed 12 AWG (2.5 mm sq). Route field cables through top or bottom cabinet wireways.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Power Inspection:\u003c\/strong\u003e Check that all terminal plugs are seated firmly, jumpers are correctly placed, and shield\/protective earth grounds are connected.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Maintenance Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe Behavior (FAILOPT):\u003c\/strong\u003e Configure channel fail-safe options via Experion control software. In the event of an IOM communication loss or system hardware fault, individual channels can be programmed to hold their last state or shed to a safe zero condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Servicing:\u003c\/strong\u003e The socketed relay design allows for individual relay replacement. When replacing socketed units, use matching AgSnO2 contact assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Life Management:\u003c\/strong\u003e For highly inductive loads, confirm that inductive derating factors (such as PF = 0.4 or L\/R = 100 ms) are respected to maintain contact longevity over the rated 50,000 electrical operations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667986608491,"sku":"CC-SDOR01 51308380-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-SDOR01-51308380-175_001_1200x1200_8ed13457-c1f9-44b1-b807-103230e2a43f.webp?v=1787723603","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-cc-sdor01-51308380-175-experion-series-c-digital-output-relay-extension-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}