{"product_id":"honeywell-cc-taox01-51308351-175-experion-pks-analog-output-iota","title":"Honeywell CC-TAOX01 51308351-175 IOTA di uscita analogica Experion PKS","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAOX01\u003c\/strong\u003e is a non-redundant Analog Output Input Output Termination Assembly (IOTA) used within the Experion PKS Series C I\/O system. It serves as the physical interface layer for mounting a Series C Analog Output module, connecting field device wiring directly to the I\/O electronics and facilitating communication with C300 controllers over the Series C I\/O Link.\u003c\/p\u003e\n\u003cp\u003eDesigned for compact control cabinet layouts, the board features an integrated, tilted mounting footprint that eliminates the need for separate field termination assembly (FTA) cables. The \u003cstrong\u003eCC-TAOX01\u003c\/strong\u003e provides 16-channel field connections, on-board fusing for loop protection, and non-incendive power distribution for 4-20 mA field loops without requiring external marshalling.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Module Interface:\u003c\/strong\u003e Mounts single Series C Analog Output I\/O Modules (IOM) directly onto the assembly, saving panel space and eliminating FTA cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Fusing:\u003c\/strong\u003e Includes dedicated on-board field wiring protection fuses for output safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Field Power:\u003c\/strong\u003e Supports 4-20 mA current loops with integrated loop power distribution without requiring external field marshalling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Screw Terminals:\u003c\/strong\u003e Features onboard screw terminal blocks for direct field wiring connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries C Architecture:\u003c\/strong\u003e Integrates directly into the Experion PKS Series C I\/O Link topology.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) process automation in Experion PKS C300 environments.\u003c\/li\u003e\n\u003cli\u003eContinuous control loops utilizing 4-20 mA analog actuators, control valves, and field indicators.\u003c\/li\u003e\n\u003cli\u003eStandard and non-incendive field wiring loop installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-TAOX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output IOTA (Non-redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-PAOH01, CC-PAOX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-Board Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF1 Fuse (Fusing for field power\/module protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Output (+) \/ Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Return (-) \/ Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Output (+) \/ Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Return (-) \/ Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals 5–32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannels 3 through 16 Output (+) and Return (-) Assignments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Screw\/Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC System Power Input \u0026amp; Common Ground Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely attach the CC-TAOX01 IOTA horizontally or vertically onto the Series C carrier assembly inside the cabinet prior to attaching the IOM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Attachment:\u003c\/strong\u003e Align and seat the Series C Analog Output Module (CC-PAOH01 or CC-PAOX01) onto the IOTA card connectors until fully engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure cabinet safety ground and signal common ground are firmly wired to the IOTA grounding studs in accordance with system design guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing Maintenance:\u003c\/strong\u003e Verify the F1 fuse rating on the board prior to energizing connected 24V field circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e Route field signal lines away from high-voltage cables to minimize noise and EMI\/RFI interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668013445483,"sku":"CC-TAOX01 51308351-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-taox01-analog-output-iota-rfna55lfkqd_4d6d29a1-286c-47d1-abdc-727868df5903.jpg?v=1765505129","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-cc-taox01-51308351-175-experion-pks-analog-output-iota","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}