{"product_id":"honeywell-experion-pks-fta-t-20-digital-output-relay-field-termination-assembly","title":"Honeywell Experion PKS FTA-T-20 Gruppo di terminazione da campo con relè di uscita digitale","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un gruppo di terminazione di campo (FTA) specializzato, appartenente agli ecosistemi\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager (SMS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Funge da interfaccia fisica ed elettrica tra i moduli di uscita digitali del sistema e le apparecchiature esterne di campo.\u003c\/p\u003e\n\u003cp\u003eProgettato per requisiti di commutazione con carichi elevati o isolati, l'FTA-T-20 offre\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 canali di uscite a contatto di relè\u003c\/strong\u003e. Ogni canale dispone di contatti\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNO (Normalmente aperto)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNC (Normalmente chiuso)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, consentendo configurazioni fail-safe flessibili. Utilizzando relè di interposizione sull'FTA, il sistema protegge l'elettronica sensibile del controller dalle sovratensioni elettriche lato campo e consente di commutare tensioni e correnti più elevate (fino a 250 Vac o 110 Vdc) rispetto a quelle gestibili da un'uscita elettronica standard.\u003c\/p\u003e\n\u003ch3\u003eConfigurazione tecnica\u003c\/h3\u003e\n\u003cp\u003eL'FTA-T-20 è progettato per una perfetta integrazione nei rack di sicurezza e controllo Honeywell:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDensità dei canali:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 canali relè indipendenti.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTipo di contatto:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigurazione SPDT (un polo, doppio contatto), con terminali NO e NC per ogni canale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnessione dell'interfaccia:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esi collega al modulo I\/O del controller tramite un cavo standard di interconnessione del sistema\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCablaggio di campo:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edotato di robusti\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emorsetti a vite\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper il collegamento diretto dei cavi di campo, compatibili con diversi diametri di filo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontaggio:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emontaggio standard su guida DIN per l'installazione in armadi I\/O o pannelli di distribuzione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgettazione NFS (Non-Fail Safe):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizzato generalmente in applicazioni in cui la logica di sicurezza è gestita dal controller e il relè funge da elemento di commutazione finale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaratteristica\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDettagli\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di uscita\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUscita digitale (contatto di relè)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumero di canali\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensione massima di commutazione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vac \/ 110 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogica dei contatti\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNO \/ NC (scambio)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCavo di interconnessione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIC-C-07\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di terminale\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMorsetti a vite (tipo T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRiferimento del modulo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10209\/2\/1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso di spedizione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti tecniche\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual è il vantaggio di utilizzare un FTA-T (morsetto a vite) rispetto a un FTA-E (ELCO)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa versione\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè progettata per il cablaggio diretto di campo, con i cavi terminati singolarmente sul gruppo. La versione\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ELCO) viene generalmente utilizzata per connessioni \"marshalling-to-marshalling\" mediante cavi multipolari prefabbricati. L'FTA-T-20 è ideale per gli armadi in cui i sensori\/attuatori di campo sono cablati direttamente al rack I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso combinare carichi CA e CC sullo stesso FTA-T-20?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSebbene i contatti dei relè siano dimensionati sia per 250 Vac sia per 110 Vdc, è prassi ingegneristica standard mantenere coerenti i tipi di carico su un FTA, per evitare disturbi e semplificare la manutenzione. Tuttavia, poiché gli 8 canali sono galvanicamente isolati tra loro, tecnicamente possono commutare sorgenti di tensione diverse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCome posso sostituire un relè guasto su questo FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA seconda della specifica revisione hardware, i relè dell'FTA-T-20 sono spesso montati su zoccolo. Ciò consente la \"manutenzione a caldo\", sostituendo un singolo relè senza sostituire l'intero gruppo di terminazione né intervenire sul cablaggio degli altri 7 canali.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuida all'ingegneria e all'installazione\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminazione dei fili:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassicurarsi di utilizzare capicorda a puntale quando si effettuano i collegamenti ai morsetti a vite. Ciò previene lo sfilacciamento dei fili e garantisce una connessione a tenuta di gas, fondamentale negli ambienti industriali corrosivi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstradamento dei cavi:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eil cavo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeve essere instradato lontano dalle linee CA ad alta potenza per evitare disturbi indotti, anche se le uscite a relè sono relativamente robuste.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtezione dei contatti:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper i carichi altamente induttivi, come le grandi elettrovalvole o gli avviatori per motori, si raccomanda di installare soppressori RC esterni (per la CA) o diodi di ricircolo (per la CC), così da prolungare la durata dei contatti dei relè dell'FTA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFusibili:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassicurarsi sempre che i circuiti lato campo siano adeguatamente protetti da fusibili. L'FTA-T-20 fornisce la logica di commutazione, mentre la protezione limitatrice di corrente deve essere gestita da fusibili terminali o interruttori automatici esterni.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667743338859,"sku":"FTA-T-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-20-fta-output-module-qqfm5mreu3l_e04138f4-fd7c-4a5d-9cc3-0b76caa2f4a1.jpg?v=1765501439","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-experion-pks-fta-t-20-digital-output-relay-field-termination-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}