{"product_id":"honeywell-fc-cpchas-0001-safety-manager-module","title":"Honeywell FC-CPCHAS-0001 Safety Manager Controller Chassis","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-CPCHAS-0001\u003c\/strong\u003e is a 19-inch rack-mounted Controller Chassis engineered to house and interface the Control Processor modules within the Honeywell Safety Manager system architecture. Installed as the main processing enclosure at the top position of a system cabinet, it provides structural housing and complete backplane interconnection for both redundant and non-redundant Safety Manager controller configurations.\u003c\/p\u003e\n\u003cp\u003eThe chassis integrates a specialized controller housing with card guides, quarter-turn module locks, and a integrated controller backplane (CPB-0001). The rear section features a magnetically locked back cover plate that swings upward to expose signal connections and a structured cable-management framework with dedicated horizontal bars for 24 Vdc supply\/signals, communication links, and 5V\/Watchdog lines. The unit routes internal power distribution—including a diode-decoupled, redundant 5V supply (5V-R) derived from connected power supply units—and interfaces up to four I\/O buses, watchdog outputs, system power, and communication lines to field I\/O racks and external networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Configuration Flexibility:\u003c\/strong\u003e Supports both single (non-redundant) and fault-tolerant redundant Control Processor setups within a single standard 19-inch housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Backplane Architecture:\u003c\/strong\u003e Incorporates the CPB-0001 controller backplane to deliver signal routing, 5V-R diode-decoupled redundant power distribution, and I\/O bus connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStructured Rear Cable Management:\u003c\/strong\u003e Features three dedicated horizontal tie-wrap bars to separate 24 Vdc power\/signals, communication cables, and low-voltage 5V\/watchdog cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwing-Up Rear Protection:\u003c\/strong\u003e Magnetically locked rear cover plate swings upward for easy access to backplane connectors during installation and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Expansion Capability:\u003c\/strong\u003e Offers interfaces for up to 4 I\/O buses with dedicated terminator sockets (TERM-0001\/TERM-0002) and 8 watchdog\/power distribution channels (WdP1–WdP8) for downstream I\/O chassis connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Control Inputs:\u003c\/strong\u003e Includes external Emergency Shut Down (SD) interlock terminals and 3 non-safety 24 Vdc general-purpose inputs (IN1–IN3) for functions such as external clock synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Manager Main Controller Enclosure:\u003c\/strong\u003e Primary processing hub housing Quad Processor Packs (QPP-0002), Universal Safety Interfaces (USI-0002 \/ FX-USI-0002), Power Supplies (PSU-240516), and Battery \u0026amp; Key Switch Modules (BKM-0001).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Shutdown (ESD) Systems:\u003c\/strong\u003e Core chassis housing for ESD logic solvers in process plants, offshore platforms, and refineries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Management Systems (BMS) \u0026amp; Fire \u0026amp; Gas (F\u0026amp;G):\u003c\/strong\u003e Central hardware frame for processing high-integrity safety loops and fire\/gas monitoring logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model\u003c\/td\u003e\n\u003ctd\u003eFC-CPCHAS-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Number\u003c\/td\u003e\n\u003ctd\u003eFS-CPCHAS-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eController Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame \/ Mounting Standard\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack Cabinet Mount (4 HE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (5V-1)\u003c\/td\u003e\n\u003ctd\u003e0.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (5V-2)\u003c\/td\u003e\n\u003ctd\u003e0.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSlot \u0026amp; Module Capacity\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Processor Slots\u003c\/td\u003e\n\u003ctd\u003eCPU1 (QPP-0002), CPU2 (QPP-0002, optional for redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Slots\u003c\/td\u003e\n\u003ctd\u003eCOM1.1, COM1.2, COM2.1, COM2.2 (USI-0002 \/ FX-USI-0002 or BLIND-COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Slots\u003c\/td\u003e\n\u003ctd\u003ePSU1 (PSU-240516), PSU2 (PSU-240516, optional for redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared Module Slot\u003c\/td\u003e\n\u003ctd\u003eBKM (BKM-0001 Battery and Key Switch Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnused Slot Cover Plate\u003c\/td\u003e\n\u003ctd\u003eBLIND-CPS (for non-redundant CPU\/PSU slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e4 HE (177 mm \/ 7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e482.6 mm \/ 19 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e280 mm \/ 11 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.8 kg \/ 12.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Cover Locking\u003c\/td\u003e\n\u003ctd\u003eMagnetic lock mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Group\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1.1.A \/ B, COM1.2.A \/ B\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eEthernet communication channels 1 and 2 for CP1 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1.1.C \/ D, COM1.2.C \/ D\u003c\/td\u003e\n\u003ctd\u003e10-pin male\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose communication channels 3 and 4 for CP1 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM2.1.A \/ B, COM2.2.A \/ B\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eEthernet communication channels 1 and 2 for CP2 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM2.1.C \/ D, COM2.2.C \/ D\u003c\/td\u003e\n\u003ctd\u003e10-pin male\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose communication channels 3 and 4 for CP2 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO bus 1 to 4 (1.1–1.4 \u0026amp; 2.1–2.4)\u003c\/td\u003e\n\u003ctd\u003eFlat cable connectors\u003c\/td\u003e\n\u003ctd\u003eI\/O bus interface links for Control Processor 1 and Control Processor 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerm IO bus 1 to 4\u003c\/td\u003e\n\u003ctd\u003e2 x 50-pin connector\u003c\/td\u003e\n\u003ctd\u003eSockets for IO bus terminators (TERM-0001 or TERM-0002)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWdP1 to WdP8\u003c\/td\u003e\n\u003ctd\u003e8-pin male\u003c\/td\u003e\n\u003ctd\u003eWatchdog and Power distribution connectors to I\/O chassis 1 through 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24V-1 \/ 24V-2\u003c\/td\u003e\n\u003ctd\u003e2-pin male\u003c\/td\u003e\n\u003ctd\u003eMain +24V power supply inputs for CP1 and CP2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5V-1 \/ 5V-2 \/ 5V-R\u003c\/td\u003e\n\u003ctd\u003e4-pin male\u003c\/td\u003e\n\u003ctd\u003e5V and Watchdog distribution to extension cabinets via PDB-IOX05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD\u003c\/td\u003e\n\u003ctd\u003e2-pin male\u003c\/td\u003e\n\u003ctd\u003eEmergency Shut Down loop input (shunted via LINK-SD if unused)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN1, IN2, IN3\u003c\/td\u003e\n\u003ctd\u003e2-pin male\u003c\/td\u003e\n\u003ctd\u003e24V non-safety general purpose inputs (IN1 supports clock sync interrupt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Install the \u003cstrong\u003eHoneywell FC-CPCHAS-0001\u003c\/strong\u003e horizontally into a standard 19-inch rack cabinet, typically positioned at the top location above the associated I\/O chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Verification:\u003c\/strong\u003e Ensure the chassis is bonded to the main cabinet frame ground. Built-in keying pins in the backplane provide chassis ground connection to module housings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Insert modules (QPP-0002, USI-0002, PSU-240516, BKM-0001) along the top and bottom guide rails through the front opening. Secure each module by tightening the quarter-turn fasteners below the module grips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlanking Plates:\u003c\/strong\u003e Fit BLIND-CPS plates over unused processor\/power supply slots and BLIND-COM plates over unused communication slots to prevent airflow bypass and contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Cable Management:\u003c\/strong\u003e Swing open the rear magnetic cover plate. Group and secure cables to the horizontal tie-wrap bars according to voltage levels:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Bar:\u003c\/strong\u003e 24 Vdc supply and 24 Vdc signal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMiddle Bar:\u003c\/strong\u003e System Ethernet and general-purpose communication cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom Bar:\u003c\/strong\u003e 5V auxiliary and Watchdog distribution cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Bus Termination:\u003c\/strong\u003e Verify that appropriate bus terminators (TERM-0001 or TERM-0002) are fully seated in all active Term IO bus sockets on the rear backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Shutdown Link:\u003c\/strong\u003e Ensure the factory-installed LINK-SD jumper remains connected across the SD terminals unless an external hardwired Emergency Shut Down contact is wired to the chassis.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Redundancy Check:\u003c\/strong\u003e Measure voltage at 5V-1, 5V-2, and 5V-R backplane test terminals. Confirm that 5V-R remains energized when either power supply module (PSU1 or PSU2) is operational.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Verification:\u003c\/strong\u003e Verify link activity on RJ45 ports (COM1.1–COM2.2) when connected to system switches or downstream Safety Manager networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt \u0026amp; Clock Sync Verification:\u003c\/strong\u003e If using IN1 for clock synchronization, verify rising-edge signal integrity and line voltage levels before enabling software interrupts.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTUV:\u003c\/strong\u003e TÜV Certified for Functional Safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM:\u003c\/strong\u003e Factory Mutual Approved\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667759985003,"sku":"FC-CPCHAS-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-CPCHAS-0001_003_1200x1200_9b3fefad-c381-4c0f-a110-f8e69b545975.jpg?v=1786801693","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-fc-cpchas-0001-safety-manager-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}