{"product_id":"honeywell-fsc-10024-h-i-26901-enhanced-communication-module","title":"Honeywell FSC 10024\/H\/I 26901 Enhanced Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10024\/H\/I\u003c\/strong\u003e (Model Type \u003cstrong\u003e26901\u003c\/strong\u003e) is an enhanced communication and interface module engineered specifically for the Honeywell Fail-Safe Control (FSC) safety system series. Designed to provide critical connectivity between systems, this rack-mounting card enables seamless inter-system data transfer and external network interface capabilities required in high-integrity industrial environments.\u003c\/p\u003e\n\u003cp\u003eOperating on a \u003cstrong\u003e5V DC\u003c\/strong\u003e internal power rail with a typical current draw of \u003cstrong\u003e675mA\u003c\/strong\u003e, the module houses an integrated central processor along with dual front-panel serial ports. The port configuration consists of port A supporting \u003cstrong\u003eRS-232\u003c\/strong\u003e communication and port B configured for differential \u003cstrong\u003eRS-422\/RS-485\u003c\/strong\u003e industrial links. This dual-interface architecture allows the FSC safety controller to interface concurrently with distributed control systems (DCS), supervisory control and data acquisition (SCADA) platforms, or dedicated operator stations without sacrificing system execution speed.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Serial Architecture:\u003c\/strong\u003e Equipped with two front-panel DB9 connectors (Ports A and B) to manage isolated serial communication channels simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Protocol Support:\u003c\/strong\u003e Supports RS-232 link protocols on Port A alongside RS-422 and RS-485 differential links on Port B for versatile field connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Processing:\u003c\/strong\u003e Features built-in central processor (CP) logic to handle communication overhead, offloading message parsing from the central FSC processing modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Rack Integration:\u003c\/strong\u003e Form-factor designed for direct insertion into standard FSC Central Part system bus racks (such as 7-slot, 12-slot, or 17-slot chassis configurations).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Runs off the internal system backplane supply at 5V DC drawing approximately 675mA under normal operational load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS and Safety System Interfacing:\u003c\/strong\u003e Establishing serial Modbus or proprietary communication links between Honeywell FSC safety systems and Honeywell Experion PKS or third-party DCS networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Device Monitoring:\u003c\/strong\u003e Connecting auxiliary industrial equipment such as local HMIs, sequence of events (SOE) recorders, and diagnostic computers to the FSC safety logic solver.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem-to-System Peer Data Transfer:\u003c\/strong\u003e Supporting serial links between multi-rack FSC node configurations or distributed safety system architectures across process sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 32.1503%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 67.4322%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003e10024\/H\/I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eModel Type\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003e26901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eSystem Series\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003eFail-Safe Control (FSC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eModule Type\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003eEnhanced Communication \/ Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003e5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003e675mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eFront Ports\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003e2 x DB9 Serial Connectors (Labeled A and B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003eRS-232 (Port A) \/ RS-422 \/ RS-485 (Port B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eProcessor Hardware\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003eIntegrated Central Processor (int. CP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1503%;\"\u003eMounting Format\u003c\/td\u003e\n\u003ctd style=\"width: 67.4322%;\"\u003eFSC Central Part System Bus Rack Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Protocol Support\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort A\u003c\/td\u003e\n\u003ctd\u003eDB9 Male\/Female Front Panel\u003c\/td\u003e\n\u003ctd\u003eSerial Communication Interface (RS-232)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort B\u003c\/td\u003e\n\u003ctd\u003eDB9 Male\/Female Front Panel\u003c\/td\u003e\n\u003ctd\u003eSerial Communication Interface (RS-422 \/ RS-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Bus\u003c\/td\u003e\n\u003ctd\u003eEdge Connector\u003c\/td\u003e\n\u003ctd\u003e5V DC Power Input and Internal FSC Bus Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Inspection:\u003c\/strong\u003e Verify system power and confirm that the backplane supply delivers stable 5V DC before inserting the card into the FSC rack chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCard Slot Alignment:\u003c\/strong\u003e Ensure the target rack slot on the FSC S7-BUS, S12-BUS, or S17-BUS is free of debris. Carefully align the card edges with the guide rails and press firmly to seat the backplane edge connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Cable Termination:\u003c\/strong\u003e For RS-422 or RS-485 connections on Port B, ensure proper line termination resistors are implemented across long cable runs to prevent signal reflection and data corruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Connect shielded twisted-pair cables to DB9 ports, ensuring proper signal grounding techniques are applied to prevent electromagnetic interference (EMI) from affecting safety communications.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Replacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter Verification:\u003c\/strong\u003e Prior to replacing an existing module, record all serial communication parameters (baud rate, parity, data bits, stop bits, node ID) configured in the FSC engineering software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swapping Precaution:\u003c\/strong\u003e Power down the slot or respect FSC rack maintenance procedures before inserting or extracting the module to protect sensitivity-critical internal logic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Check:\u003c\/strong\u003e After installation, verify status LEDs on the front panel and initiate communication diagnostic tests from the master control station to confirm active Tx\/Rx data transfer on both Port A and Port B.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668020556139,"sku":"10024\/H\/I","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-10024-h-i-communication-module-oba4pyrbr3j_e2f932ce-247f-4fcb-9b85-aaaec664d435.jpg?v=1765505201","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-fsc-10024-h-i-26901-enhanced-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}