{"product_id":"honeywell-mc-tamr04-51305907-175-low-level-input-multiplexer","title":"Honeywell MC-TAMR04 51305907-175 Multiplexer degli ingressi a basso livello","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MC-TAMR04 (Model 51305907-175) is a specialized low-level input multiplexer module engineered for integration within legacy Honeywell Distributed Control Systems (DCS), specifically supporting the TDC 3000 and related process automation platforms. This hardware component is designed to manage and condition low-level analog signals originating from sensitive industrial field instrumentation, such as thermocouples and RTDs, before passing them on to the greater control system architecture.\u003c\/p\u003e\n\u003cp\u003eAs an essential interface in heavy industrial control schemes, the MC-TAMR04 multiplexes multiple low-level input signals into a centralized processing stream, reducing cabling complexity while maintaining high signal integrity and measurement accuracy. Its construction adheres to strict industrial standards to ensure reliable performance inside standard control room marshaling cabinets or remote node enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for Honeywell TDC 3000 and legacy Experion\/DCS architecture environments\u003c\/li\u003e\n  \u003cli\u003ePrecision low-level signal multiplexing for thermocouple and millivolt inputs\u003c\/li\u003e\n  \u003cli\u003eReduces extensive field wiring by consolidating multiple sensor inputs\u003c\/li\u003e\n  \u003cli\u003eStandardized form factor for seamless rack or chassis mounting in industrial cabinets\u003c\/li\u003e\n  \u003cli\u003eBuilt to meet rigorous industrial operational and noise-immunity standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation facilities and turbine monitoring\u003c\/li\u003e\n  \u003cli\u003eRefining and oil \u0026amp; gas production units\u003c\/li\u003e\n  \u003cli\u003eLarge-scale continuous manufacturing and process control loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003eMC-TAMR04 \/ 51305907-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eTDC 3000 \/ MU-T Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eLow Level Input Multiplexer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompatible Control Systems\u003c\/td\u003e\n      \u003ctd\u003eHoneywell TDC 3000 DCS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.5 kg (Approximate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the control system power and associated field signal lines are fully de-energized before handling the module.\u003c\/li\u003e\n  \u003cli\u003eInspect the MC-TAMR04 51305907-175 unit for any transit damage or bent pins on the connector backplane interface.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely into the designated slot within the system cabinet backplane or chassis.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring and signal terminations carefully, adhering to proper shielding and grounding practices to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eRe-energize the system and verify module health and signal communication via the engineering workstation or controller diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667738390891,"sku":"MC-TAMR04 51305907-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mc-tamr04-51305907-175-low-level-input-multiplexer-groy30pkvux_c410eeb0-9325-4639-8a2f-baa960adbe58.jpg?v=1765501364","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-mc-tamr04-51305907-175-low-level-input-multiplexer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}