{"product_id":"honeywell-mu-tpix12-51304084-100-pulse-input-fta-module","title":"Honeywell MU-TPIX12 51304084-100 Pulse Input FTA Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MU-TPIX12 (model 51304084-100) is a high-reliability Pulse Input Field Termination Assembly (FTA) designed for use within Honeywell Experion PKS and related distributed control systems (DCS). This module serves as a critical interface between industrial field instrumentation—such as flow meters, tachometers, and pulse-generating sensors—and the system I\/O cards, translating frequency and pulse signals into accurate control data.\u003c\/p\u003e\n\u003cp\u003eEngineered for mission-critical industrial applications, the MU-TPIX12 facilitates efficient signal conditioning and routing. It minimizes electrical noise interference and ensures high-fidelity pulse train transmission. The assembly integrates directly into standard Honeywell cabinet architectures, providing dependable point-to-point connection security for continuous process monitoring and batch measurement applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned specifically for pulse input and frequency measurement field signals\u003c\/li\u003e\n  \u003cli\u003eProvides secure termination and signal conditioning for high-accuracy meters\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard Honeywell Experion PKS DCS system architectures\u003c\/li\u003e\n  \u003cli\u003eRobust industrial construction built to withstand demanding plant environments\u003c\/li\u003e\n  \u003cli\u003eStandardized connectivity utilizing reliable multi-pin interface cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFlow measurement and custody transfer monitoring\u003c\/li\u003e\n  \u003cli\u003eTurbine speed and rotational velocity acquisition\u003c\/li\u003e\n  \u003cli\u003eBatch processing and totalization loops\u003c\/li\u003e\n  \u003cli\u003eOil and gas production facilities\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical refining plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eMU-TPIX12\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e51304084-100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePulse Input FTA (Field Termination Assembly)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Family\u003c\/td\u003e\n      \u003ctd\u003eExperion PKS DCS \/ MU-T Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Type\u003c\/td\u003e\n      \u003ctd\u003ePulse \/ Frequency signals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003eDIN rail or panel mounting via standard Honeywell hardware\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eField Terminations\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals for direct connection of field sensor signal wires\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Cable Connector\u003c\/td\u003e\n      \u003ctd\u003eMulti-pin D-sub connector linking the FTA to the I\/O module\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify the part number and ensure the exact model MU-TPIX12 51304084-100 matches your system design specifications.\u003c\/li\u003e\n  \u003cli\u003eDe-energize the associated cabinet power and I\/O channels before handling wiring or hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the termination board and connectors for any transport damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eMount the FTA securely to the designated panel or DIN rail within the control cabinet.\u003c\/li\u003e\n  \u003cli\u003eConnect field sensor leads to the appropriate screw terminals following standard loop drawings.\u003c\/li\u003e\n  \u003cli\u003eAttach the system pre-formed cable between the FTA D-sub connector and the corresponding I\/O module.\u003c\/li\u003e\n  \u003cli\u003eRestore power and verify signal scaling and pulse reception via the Experion DCS engineering station.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667745567083,"sku":"MU-TPIX12 51304084-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mu-tpix12-51304084-100-pulse-input-fta-plc-module-kke3tmtcsel_033a1a64-bc11-4b5c-8b0e-33cdf59f8eb6.jpg?v=1765501474","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-mu-tpix12-51304084-100-pulse-input-fta-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}