{"product_id":"honeywell-tk-mdp081-51404351-175-experion-lx-high-speed-pulse-input-module","title":"Honeywell TK-MDP081 51404351-175 Experion LX High Speed Pulse Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-MDP081\u003c\/strong\u003e (Part Number \u003cstrong\u003e51404351-175\u003c\/strong\u003e) is a conformal coated, single-slot High Speed Pulse Input (PI) specialty module developed for the Honeywell Experion Series-A Chassis I\/O (CIOM-A) platform. Designed to provide accurate pulse counting and frequency processing, the module features 8 high-speed counter input channels alongside 2 dedicated On\/Off outputs. It acts as a specialized process interface for turbine meters, flowmeters, tachometers, and other pulse-generating field equipment within Honeywell C200 and C200E control systems.\u003c\/p\u003e\n\u003cp\u003eEngineered to operate seamlessly across Experion control networks, the \u003cstrong\u003eTK-MDP081\u003c\/strong\u003e communicates across the chassis backplane and integrates into the system topology via ControlNet interface modules. Its onboard counting capabilities process high-frequency pulse trains locally, alleviating CPU processing overhead and ensuring precise totalization, rate measurement, and real-time control response.\u003c\/p\u003e\n\u003cp\u003eAs part of the Experion Series-A chassis family, the module mounts directly into any available slot position within 4-, 7-, 10-, 13-, or 17-slot Series-A chassis. Built-in conformal coating ensures long-term operational integrity in harsh industrial environments containing airborne corrosive contaminants.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Channel Design:\u003c\/strong\u003e Equipped with 8 high-speed counter inputs and 2 discrete On\/Off outputs in a single-slot form factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Protection:\u003c\/strong\u003e Comes standard with factory conformal coating (TK prefix) to withstand ISA Class G3 harsh environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Operates within the Experion CIOM-A chassis family and interfaces directly with C200 and C200E control processors via ControlNet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Termination Options:\u003c\/strong\u003e Uses a standard 36-pin removable terminal block (TC-TBCH) or pre-wired Remote Terminal Panel (RTP) cable assemblies for efficient cabinet wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Maintenance:\u003c\/strong\u003e Supports Removal and Insertion Under Power (RIUP) in ordinary (non-hazardous) locations to minimize operational downtime during service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Totalization \u0026amp; Rate Monitoring:\u003c\/strong\u003e Direct interface to pulse-output liquid\/gas flowmeters and turbine meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotational Speed \u0026amp; Velocity Tracking:\u003c\/strong\u003e Processing tachometer and encoder pulse feedback on rotating machinery, pumps, and motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatching \u0026amp; Dosing Control:\u003c\/strong\u003e High-speed event counting combined with onboard discrete outputs for direct valve or actuator control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Signal Processing:\u003c\/strong\u003e Accumulation and frequency evaluation of high-speed field signals in industrial process control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eTK-MDP081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51404351-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Speed Pulse Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eExperion LX \/ Experion PKS Series-A I\/O (CIOM-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSingle-wide chassis slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eYes (TK Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquivalent Allen-Bradley Model\u003c\/td\u003e\n\u003ctd\u003e1756-IJ4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eI\/O Capacity \u0026amp; Features\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Speed Counter Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete On\/Off Outputs\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Terminal Block\u003c\/td\u003e\n\u003ctd\u003e36-pin (TC-TBCH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% noncondensing (up to 40 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Atmosphere\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA-S71.04-1985 Class G1, G2, and G3 (Harsh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e-300 to +3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock (Operating)\u003c\/td\u003e\n\u003ctd\u003e5 g max., 30 ms duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock (Transportation)\u003c\/td\u003e\n\u003ctd\u003e20 g max., 30 ms duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration (Operating)\u003c\/td\u003e\n\u003ctd\u003e10 to 60 Hz, 0.5 g max., 0.1 inch displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWiring Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 1: Direct Wiring\u003c\/td\u003e\n\u003ctd\u003eTC-TBCH\u003c\/td\u003e\n\u003ctd\u003e36-pin removable terminal block supporting 1 wire @ 16-22 AWG (0.64-1.30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 2: Pre-Wired Cable\u003c\/td\u003e\n\u003ctd\u003e1492-HWCAB###\u003c\/td\u003e\n\u003ctd\u003ePre-wired cable with Honeywell slide-on cover connecting module to Remote Terminal Panel (RTP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 2: Remote Terminal Panel\u003c\/td\u003e\n\u003ctd\u003e1492-IFM \/ 1492-RIFM\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mounted terminal panel for field wiring interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify the module part number (\u003cstrong\u003eTK-MDP081\u003c\/strong\u003e \/ \u003cstrong\u003e51404351-175\u003c\/strong\u003e) and inspect the board and pins for physical damage prior to installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Backplane Check:\u003c\/strong\u003e Ensure the Series-A power supply capacity (24 VDC, 5 VDC, 3.3 VDC, and 1.2 VDC outputs) is calculated to support all installed modules without exceeding the 70 W \/ 75 W total output limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Insertion:\u003c\/strong\u003e Align the single-wide module with the guide rails of the target slot in the CIOM-A chassis and push firmly until the module is securely latched into the backplane connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination:\u003c\/strong\u003e Connect field pulse signals to either the 36-pin TC-TBCH terminal block or the pre-wired Allen-Bradley 1492 RTP cable assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Route pulse input signal cables separately from high-voltage AC lines to prevent electrical noise interference on high-speed counting lines. Ensure shield wires are properly grounded at designated panel tie-points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swapping (RIUP):\u003c\/strong\u003e Removal and insertion under power is permitted in non-hazardous locations. Ensure hot-work permits are obtained if operating in Class I, Division 2 hazardous areas.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eStandard \/ Classification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety \/ Industrial Control\u003c\/td\u003e\n\u003ctd\u003eUL 508 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eClass I, Div 2, Groups A, B, C \u0026amp; D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Conformity\u003c\/td\u003e\n\u003ctd\u003eCE Mark (EN 50081-2 Emissions, EN 50082-2 Immunity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC-Tick\u003c\/td\u003e\n\u003ctd\u003eAustralian Radiocommunications Act Section 182\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668033991019,"sku":"TK-MDP081 51404351-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TK-MDP081-51404351-175_004_1200x1200_efc57eaa-4f7a-4945-8e0b-690508aab891.jpg?v=1786886251","url":"https:\/\/www.plcprotech.com\/it\/products\/honeywell-tk-mdp081-51404351-175-experion-lx-high-speed-pulse-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}