{"product_id":"ics-triplex-t9300-aadvance-i-o-base-unit","title":"ICS Triplex T9300 AADvance I\/O Base Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe ICS Triplex \u003cstrong\u003eT9300\u003c\/strong\u003e is an I\/O base unit designed for functional safety and critical control applications within the AADvance system architecture. It serves as the physical and electrical backplane interface that holds up to three AADvance I\/O modules, connecting them to command and response buses and mating directly with termination assemblies to route field wiring. Grounded in a high-density compact design, the \u003cstrong\u003eT9300\u003c\/strong\u003e features integrated side connectors and locking plastic clips that allow direct plug-and-socket bus expansion across multiple I\/O base unit rows without requiring inter-module wiring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccommodates up to three AADvance I\/O modules per base unit\u003c\/li\u003e\n\u003cli\u003eMates directly with simplex, dual, and triple (TMR) field termination assemblies\u003c\/li\u003e\n\u003cli\u003eInterconnects side-by-side using integrated bus connectors and plastic locking clips\u003c\/li\u003e\n\u003cli\u003eSupports multi-row extension via T9310 expansion cables\u003c\/li\u003e\n\u003cli\u003eProvides vertical DIN rail (TS35) or direct panel mounting options\u003c\/li\u003e\n\u003cli\u003eConformally coated printed circuit boards meeting MIL-1-46058C and IPC-CC-830 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown (ESD) Systems\u003c\/li\u003e\n\u003cli\u003eFire and Gas (F\u0026amp;G) Protection Systems\u003c\/li\u003e\n\u003cli\u003eCritical Process Control Applications\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eBoiler and Furnace Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eT9300\u003c\/td\u003e\n\u003ctd\u003eAADvance I\/O Base Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT9300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Base Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3 I\/O modules per base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 Vdc to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Backplane Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 A (400 mA per slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 degC to +60 degC (-13 degF to +140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC (-40 degF to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 m to 2,000 m (0 ft to 6,600 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration (Withstand)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 150 Hz, 0.1 g acceleration in 3 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock (Operating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 g peak, 11 ms duration, half sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e233 mm x 126 mm x 18 mm (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (Base Unit Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePollution Degree 2 (per IEC 60664-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Must be installed in the vertical orientation only when used in certified safety or hazardous environment applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Options:\u003c\/strong\u003e Secure to a pair of parallel TS35 standard symmetric DIN rails (35 mm x 7.5 mm) or direct panel mount using three M5 screws per base unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance Requirements:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the base unit for field wiring adjustment and module latching\/removal, 30 mm to the right, and at least 140 mm front depth clearance from the mounting panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e Must be installed inside an IP54 tool-accessible enclosure suitable for Pollution Degree 2 environments for both non-hazardous and ATEX\/IECEx Class I, Division 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Unit Interconnection:\u003c\/strong\u003e Connect adjacent I\/O base units to the right side of the T9100 processor base unit or another T9300 base unit using direct plug-and-socket headers, securing the top and bottom with plastic locking clips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Cables:\u003c\/strong\u003e Use T9310 expansion cables to route I\/O Bus connections to additional base unit rows; ensure total bus length does not exceed 8 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed:\u003c\/strong\u003e File E341697 (UL508, CSA C22.2 No 142)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Certification:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, D (ANSI\/ISA 12.12.01-2013, CSA C22.2 No 213-M1987, File E251761)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e DEMKO 11 ATEX 1129711X, Ex nA IIC T4 Gc (EN 60079-0, EN 60079-15)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e IECEx UL 12.0032X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Certified for SIL 2 and SIL 3 applications in accordance with IEC 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e KCC-EMC Registration Class A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53240105468267,"sku":"T9300","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ICS-Triplex-T9300_001_1200x1200_0241590c-a0e3-4607-a015-380a801adaed.jpg?v=1786601840","url":"https:\/\/www.plcprotech.com\/it\/products\/ics-triplex-t9300-aadvance-i-o-base-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}