{"product_id":"lenze-e82ev-552k2c-8200-vector-frequency-inverter","title":"Lenze E82EV-552K2C 8200 Vector Frequency Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eLenze E82EV-552K2C\u003c\/strong\u003e is a \u003cstrong\u003evector-controlled frequency inverter\u003c\/strong\u003e designed for \u003cstrong\u003evariable-speed motor control in industrial machines\u003c\/strong\u003e. It belongs to the \u003cstrong\u003e8200 vector\u003c\/strong\u003e series and uses a built-in construction for installation within an electrical enclosure. The drive incorporates motor connections, a relay output and a motor temperature monitoring input for a PTC sensor or normally closed thermal contact.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eAIF automation interface\u003c\/strong\u003e accepts optional keypad and communication modules. The \u003cstrong\u003eFIF function interface\u003c\/strong\u003e accepts optional Standard I\/O, Application I\/O or fieldbus function modules. \u003cstrong\u003ePROFIBUS-DP\u003c\/strong\u003e and \u003cstrong\u003eINTERBUS\u003c\/strong\u003e communication requires the corresponding optional module. Drive configuration includes motor parameter identification, adjustable acceleration and deceleration, and parameter-set management.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eParameter saving, loading, copying and restoration through C0002, with drive-to-drive parameter transfer using an optional keypad.\u003c\/li\u003e\n\u003cli\u003eConfigurable user menu for selected operating parameters and an ALL menu for access to the complete code list.\u003c\/li\u003e\n\u003cli\u003eMotor parameter identification through C0148.\u003c\/li\u003e\n\u003cli\u003eDirection selection, DC injection braking and fixed setpoint selection through configured digital inputs on a suitable I\/O function module.\u003c\/li\u003e\n\u003cli\u003eRed and green LEDs for operating-status indication, with fault-code display available through an optional keypad.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable-speed motor drives installed in industrial machines and electrical systems.\u003c\/li\u003e\n\u003cli\u003eMachine drives requiring adjustable acceleration, deceleration and fixed operating setpoints.\u003c\/li\u003e\n\u003cli\u003eAutomated installations integrating drive control through optional PROFIBUS-DP or INTERBUS communication modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct series\u003c\/td\u003e\n\u003ctd\u003e8200 vector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eVector-controlled frequency inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eBuilt-in unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage class\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive generation\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter sets\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter-set activation\u003c\/td\u003e\n\u003ctd\u003eDigital signals configured through C0410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault control characteristic\u003c\/td\u003e\n\u003ctd\u003eLinear V\/f\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum output frequency setting, C0010\u003c\/td\u003e\n\u003ctd\u003eFactory setting: 0.00 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output frequency setting, C0011\u003c\/td\u003e\n\u003ctd\u003eFactory setting: 50.00 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain setpoint acceleration time, C0012\u003c\/td\u003e\n\u003ctd\u003eFactory setting: 5.00 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain setpoint deceleration time, C0013\u003c\/td\u003e\n\u003ctd\u003eFactory setting: 5.00 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV\/f rated frequency, C0015\u003c\/td\u003e\n\u003ctd\u003eFactory setting: 50.00 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1.1\u003c\/td\u003e\n\u003ctd\u003eIntegrated terminal strip for mains connection and DC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1.2\u003c\/td\u003e\n\u003ctd\u003eRelay-output terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX2.1\u003c\/td\u003e\n\u003ctd\u003eIntegrated terminal strip for motor connection and optional brake resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX2.2\u003c\/td\u003e\n\u003ctd\u003eMotor PTC connection or normally closed motor thermal contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor PE and shield connection at X2.1\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal strip for motor protective earth and motor cable shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIF\u003c\/td\u003e\n\u003ctd\u003eAutomation interface for optional E82ZBC keypad, EMZ9371BC keypad XT or type 21XX communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIF with optional fieldbus module\u003c\/td\u003e\n\u003ctd\u003eINTERBUS through module 2111 or PROFIBUS-DP through module 2133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFIF\u003c\/td\u003e\n\u003ctd\u003eFunction interface for optional Standard I\/O E82ZAFSC or Application I\/O E82ZAFAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFIF with optional fieldbus module\u003c\/td\u003e\n\u003ctd\u003eINTERBUS through E82ZAFIC or PROFIBUS-DP through E82ZAFPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the inverter inside an enclosure suitable for EMC-compliant installation. Maintain metallic contact between the cabinet doors and housing, and minimize unnecessary enclosure openings.\u003c\/li\u003e\n\u003cli\u003eConnect protective earth and secure motor and control cable shields using the designated shield connections and clamps.\u003c\/li\u003e\n\u003cli\u003eKeep cooling surfaces and ventilation openings unobstructed. Remove accumulated contamination without damaging the cooling surfaces.\u003c\/li\u003e\n\u003cli\u003eDisconnect the mains and any external supplies before working on terminal blocks. Wait at least 3 minutes, then verify that power terminals, relay connections and FIF contacts are de-energized.\u003c\/li\u003e\n\u003cli\u003eConnect or disconnect pluggable terminal blocks only while the inverter is isolated from its power supply.\u003c\/li\u003e\n\u003cli\u003eAllow at least 3 minutes between successive mains switch-on operations.\u003c\/li\u003e\n\u003cli\u003eIf a residual current device is used on the supply side, use a type B device.\u003c\/li\u003e\n\u003cli\u003eConfigure the motor parameters and operating setpoints before enabling the drive. Perform motor parameter identification through C0148 where required by the selected operating mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDirective or Standard\u003c\/th\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-Voltage Directive 2006\/95\/EC\u003c\/td\u003e\n\u003ctd\u003eController compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN 61800-5-1\u003c\/td\u003e\n\u003ctd\u003eApplicable harmonised standard for the controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN 61800-3\u003c\/td\u003e\n\u003ctd\u003eInstallation in category C2 drive systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":54490825916779,"sku":"E82EV-552K2C","price":5000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/E82EV-552K2C_1200x1200_e62a1f8d-4f45-4512-9132-42aa134bc93e.webp?v=1795081436","url":"https:\/\/www.plcprotech.com\/it\/products\/lenze-e82ev-552k2c-8200-vector-frequency-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}