{"product_id":"phoenix-contact-2866789-quint-ps-1ac-24dc-40-power-supply-unit","title":"Phoenix Contact 2866789 QUINT-PS\/1AC\/24DC\/40 Power Supply Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePhoenix Contact 2866789 QUINT-PS\/1AC\/24DC\/40\u003c\/strong\u003e is a primary-switched DIN rail \u003cstrong\u003epower supply unit\u003c\/strong\u003e engineered to deliver a regulated 24 V DC output at 40 A for high-availability industrial automation environments. Operating on a single-phase AC or DC input range, the \u003cstrong\u003e2866789\u003c\/strong\u003e power supply incorporates \u003cstrong\u003eSFB (Selective Fuse Breaking) Technology\u003c\/strong\u003e, which magnetically trips standard circuit breakers at six times the nominal current within 12 ms for selective branch protection. It features a static \u003cstrong\u003ePOWER BOOST\u003c\/strong\u003e power reserve providing up to 45 A permanently to start heavy electrical loads, alongside preventive function monitoring that reports critical operational states prior to error occurrence. The output voltage is continuously adjustable from 18 V DC to 29.5 V DC to accommodate targeted control cabinet applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDynamic SFB technology supplying up to 6 times nominal current for 12 ms to quickly trip standard circuit breakers\u003c\/li\u003e\n\u003cli\u003eStatic POWER BOOST power reserve delivering up to 1.5 times nominal current continuously for heavy load startup\u003c\/li\u003e\n\u003cli\u003ePreventive function monitoring to signal critical operating conditions before faults occur\u003c\/li\u003e\n\u003cli\u003eAdjustable DC output voltage range spanning 18 V DC to 29.5 V DC\u003c\/li\u003e\n\u003cli\u003ePrimary-switched design engineered for horizontal DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial control cabinets and DCS\/PLC system automation requiring reliable 24 V DC power\u003c\/li\u003e\n\u003cli\u003eAutomation applications demanding high surge currents for heavy load startup\u003c\/li\u003e\n\u003cli\u003ePower distribution networks requiring selective circuit breaker tripping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePacking Unit (VPE)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2866789\u003c\/td\u003e\n\u003ctd\u003eQUINT-PS\/1AC\/24DC\/40\u003c\/td\u003e\n\u003ctd\u003e4046356421720\u003c\/td\u003e\n\u003ctd\u003e1 pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ePhoenix Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n\u003ctd\u003e2866789 (QUINT-PS\/1AC\/24DC\/40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eThailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrimary-switched power supply unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100 V AC ... 240 V AC \/ 120 V DC ... 300 V DC (UL 508: \u0026lt;= 250 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 V AC ... 264 V AC \/ 90 V DC ... 300 V DC (UL 508: \u0026lt;= 250 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Frequency Range\u003c\/td\u003e\n\u003ctd\u003e45 Hz ... 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e8.8 A (120 V AC) \/ 4.6 A (230 V AC) \/ 9.5 A (110 V DC) \/ 4.7 A (220 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power Consumption\u003c\/td\u003e\n\u003ctd\u003e1157 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Surge Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15 A (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Buffering\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 35 ms (120 V AC) \/ \u0026gt; 35 ms (230 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e20 A (slow-blow, internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC +\/-1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Setting Range\u003c\/td\u003e\n\u003ctd\u003e18 V DC ... 29.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current (IN)\u003c\/td\u003e\n\u003ctd\u003e40 A (-25 degC ... 60 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOWER BOOST Current (IBoost)\u003c\/td\u003e\n\u003ctd\u003e45 A (-25 degC ... 40 degC permanent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelective Fuse Breaking Current (ISFB)\u003c\/td\u003e\n\u003ctd\u003e215 A (12 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 92 % (230 V AC, nominal values)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Ripple\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 30 mVPP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Dissipation (No-Load)\u003c\/td\u003e\n\u003ctd\u003e14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Loss (Nominal Load)\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-25 degC ... 70 degC (\u0026gt; 60 degC Derating: 2.5 %\/K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Start-up Tested)\u003c\/td\u003e\n\u003ctd\u003e-40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Storage\/Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 degC ... 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Permissible Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 95 % (at 25 degC, non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF (IEC 61709)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 900,000 h (25 degC) \/ \u0026gt; 530,000 h (40 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e180 mm x 130 mm x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eL (+)\u003c\/td\u003e\n\u003ctd\u003ePhase \/ Positive AC\/DC Input Connection (Screw M3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN (-)\u003c\/td\u003e\n\u003ctd\u003eNeutral \/ Negative AC\/DC Input Connection (Screw M3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePE\u003c\/td\u003e\n\u003ctd\u003eProtective Earth Ground Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\u003c\/td\u003e\n\u003ctd\u003e+24 V DC Output Terminal (Screw M4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e0 V DC Output Terminal (Screw M4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC OK\u003c\/td\u003e\n\u003ctd\u003eTransistor Output Signal for Preventive Function Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI \u0026lt; IN\u003c\/td\u003e\n\u003ctd\u003eTransistor Output Signal for Output Power Load Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13 \/ 14\u003c\/td\u003e\n\u003ctd\u003eFloating Relay Contact for Remote Status Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount horizontally on NS 35 DIN rails according to EN 60715.\u003c\/li\u003e\n\u003cli\u003eFor nominal load PN \u0026gt;= 50%, maintain installation clearances of 5 mm horizontally, 15 mm adjacent to active components, and 50 mm vertically.\u003c\/li\u003e\n\u003cli\u003eFor nominal load PN \u0026lt; 50%, maintain clearances of 0 mm horizontally, 40 mm vertically above, and 20 mm vertically below.\u003c\/li\u003e\n\u003cli\u003eEnsure input wiring complies with screw M3 connection standards (0.2 mm2 to 6 mm2 solid \/ 0.2 mm2 to 4 mm2 flexible) and output wiring complies with screw M4 connection standards (0.5 mm2 to 16 mm2).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU (EN 55011 \/ EN 55022, EN 61000-6-2:2005, EN 61000-6-3)\u003c\/li\u003e\n\u003cli\u003eLow Voltage Directive 2006\/95\/EC (IEC 60950-1 SELV, EN 50178 PELV, EN 60204-1 PELV)\u003c\/li\u003e\n\u003cli\u003eUL Approvals: UL Listed UL 508, UL\/C-UL Recognized UL 60950-1, ANSI\/ISA12.12.01 Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eShipbuilding Approvals: DNV GL, ABS, LR, RINA, NK, BV\u003c\/li\u003e\n\u003cli\u003eAdditional Approvals: CSA, IECEE CB Scheme, SEMI F47, EAC, EN 50121-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Phoenix Contact","offers":[{"title":"Default Title","offer_id":53698296414571,"sku":"2866789","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/QUINT-PS-1AC-24DC-40-2866789_001_1200x1200_1d699cd2-fbef-47d7-a0e3-687ef1a6551a.jpg?v=1786367462","url":"https:\/\/www.plcprotech.com\/it\/products\/phoenix-contact-2866789-quint-ps-1ac-24dc-40-power-supply-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}