{"product_id":"schneider-electric-140dao84000-modicon-quantum-ac-discrete-output-module","title":"Schneider Electric 140DAO84000 Modicon Quantum AC Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 140DAO84000\u003c\/strong\u003e is an AC discrete output module engineered for switching high-power alternating current field loads within the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e. Featuring 16 individually isolated channels organized in 16 groups of 1 point, this module allows independent line phase sourcing across multiple AC control circuits operating between 20 VAC and 253 VAC at supply frequencies of 47 Hz to 63 Hz.\u003c\/p\u003e\n\u003cp\u003eDesigned for switching inductive and resistive field devices such as solenoids, motor starters, control relays, and indicators, the \u003cstrong\u003e140DAO84000\u003c\/strong\u003e provides robust load-handling capability. It delivers a continuous output current rating of up to 4 A rms per point at 24...115 VAC or 3 A rms per point at 200...230 VAC, with a maximum module total rating of 16 A rms. The module incorporates internal RC filtering for surge suppression and dv\/dt protection rated at 400 V\/ms. Front-panel visual diagnostics include a green LED for active bus communication, a red LED for external fault detection, and 16 individual green point status LEDs for fast channel troubleshooting.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 channel-to-channel isolated AC discrete output channels arranged in 16 single-point groups.\u003c\/li\u003e\n\u003cli\u003eWide operating discrete output voltage range of 20 VAC to 253 VAC (47...63 Hz).\u003c\/li\u003e\n\u003cli\u003eHigh continuous output capacity rating up to 4 A rms per point (24...115 V) and 16 A rms total per module.\u003c\/li\u003e\n\u003cli\u003eFast switching performance with state transition response times of 0.5 ms or less.\u003c\/li\u003e\n\u003cli\u003eHigh surge current handling capacity up to 30 A for 1 cycle.\u003c\/li\u003e\n\u003cli\u003eBuilt-in internal RC filtering for transient voltage suppression and dv\/dt protection.\u003c\/li\u003e\n\u003cli\u003eClear local diagnostic LEDs indicating backplane bus communication, external fault status, and individual channel logic states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfacing 120 VAC \/ 230 VAC control field devices directly with Modicon Quantum PLC systems.\u003c\/li\u003e\n\u003cli\u003eDirect switching of AC solenoids, contactors, motor starter coils, and actuator drives.\u003c\/li\u003e\n\u003cli\u003eApplications requiring independent channel isolation across different AC supply phases or separate voltage sources.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct \/ Component Type\u003c\/td\u003e\n\u003ctd\u003eAC discrete output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e1 output word\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard Quantum backplane rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.485 kg (1.069 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOutput \u0026amp; Electrical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Type\u003c\/td\u003e\n\u003ctd\u003eIsolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Topology\u003c\/td\u003e\n\u003ctd\u003e16 groups of 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e20...253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e47...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Load Current (Per Point)\u003c\/td\u003e\n\u003ctd\u003e4 A rms at 24...115 V AC \/ 3 A rms at 200...230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Load Current (Group \/ Module)\u003c\/td\u003e\n\u003ctd\u003e4 A rms sum of 4 points \/ 16 A rms maximum per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Voltage\u003c\/td\u003e\n\u003ctd\u003e300 Vrms (10 s AC) \/ 400 Vrms (1 cycle AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1 mA rms (24 Vrms) \/ 1 mA rms (48 Vrms) \/ 2 mA rms (115 Vrms) \/ 2.5 mA rms (230 Vrms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current Capability\u003c\/td\u003e\n\u003ctd\u003e10 A (3 cycles) \/ 20 A (2 cycles) \/ 30 A (1 cycle) per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Voltage Rate (DV\/dt)\u003c\/td\u003e\n\u003ctd\u003e400 V\/ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.5 ms (Off to On) \/ \u0026lt;= 0.5 ms (On to Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.85 W + (1.1 V x total module load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eInternal by RC filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eVisual Indicators \u0026amp; Environment\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e1 green LED (bus active), 1 red LED (external fault), 16 green LEDs (channel state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m (16404.2 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1, 2\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 1 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3, 4\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 2 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5, 6\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 3 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7, 8\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 4 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9, 10\u003c\/td\u003e\n\u003ctd\u003eNot Connected (N\/C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11, 12\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 5 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13, 14\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 6 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15, 16\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 7 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e17, 18\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 8 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e19, 20\u003c\/td\u003e\n\u003ctd\u003eNot Connected (N\/C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e21, 22\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 9 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e23, 24\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 10 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25, 26\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 11 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e27, 28\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 12 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e29, 30\u003c\/td\u003e\n\u003ctd\u003eNot Connected (N\/C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e31, 32\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 13 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e33, 34\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 14 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35, 36\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 15 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e37, 38\u003c\/td\u003e\n\u003ctd\u003eOutput Channel 16 Hot \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e39, 40\u003c\/td\u003e\n\u003ctd\u003eNot Connected (N\/C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure main backplane rack power and external field wiring power sources are switched off prior to installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eInsert the module firmly into its designated Quantum rack slot until the backplane connector seats completely and retaining latches engage.\u003c\/li\u003e\n\u003cli\u003eWire the field AC voltage source and external loads to the assigned terminal block pins following channel isolation requirements.\u003c\/li\u003e\n\u003cli\u003eInstall fast-acting external fuses (recommended 5 A rating) in series with the AC power feeds to protect internal output circuitry and external field wiring.\u003c\/li\u003e\n\u003cli\u003eVerify that off-state leakage currents (up to 2.5 mA rms at 230 VAC) will not cause low-current high-impedance field loads to remain energized.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCommissioning Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower up the Quantum rack backplane and confirm that the top green \u003cstrong\u003eActive\u003c\/strong\u003e LED illuminates to signal proper bus communication.\u003c\/li\u003e\n\u003cli\u003eCheck the red \u003cstrong\u003eF\u003c\/strong\u003e LED indicator; if illuminated, inspect field supply wiring and external fusing for faults.\u003c\/li\u003e\n\u003cli\u003eTrigger individual output bits from the PLC software program and verify that the corresponding green channel status LED toggles on and off.\u003c\/li\u003e\n\u003cli\u003eConfirm total current draw does not exceed 4 A rms continuous for any 4-point group or 16 A rms total for the module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eStandard \/ Certification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL 508, CSA C22.2 No 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, cUL, FM Class 1 Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic Discharge Immunity\u003c\/td\u003e\n\u003ctd\u003eIEC 801-2 (4 kV contact discharge \/ 8 kV air discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Field Susceptibility\u003c\/td\u003e\n\u003ctd\u003eIEC 801-3 (10 V\/m, 80...1000 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSustainability Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104537338219,"sku":"140DAO84000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140dao84000-a4csglo5bvu.png?v=1776159579","url":"https:\/\/www.plcprotech.com\/it\/products\/schneider-electric-140dao84000-modicon-quantum-ac-discrete-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}