{"product_id":"schneider-electric-modicon-quantum-140cps11420-ac-power-supply-module","title":"Schneider Electric Modicon Quantum 140CPS11420 AC Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric Modicon Quantum 140CPS11420\u003c\/strong\u003e is a summable or standalone AC power supply module designed to deliver regulated power to backplane components within the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e. Operating on nominal input voltages of 115 VAC or 230 VAC, the unit converts main power sources into a stable 5.1 VDC output, delivering up to 11 A in standalone mode or up to 20 A when used in a summable configuration at 60 degC.\u003c\/p\u003e\n\u003cp\u003eEngineered to support system reliability, the \u003cstrong\u003e140CPS11420\u003c\/strong\u003e integrates internal overvoltage and overload protection mechanisms alongside a dedicated power-loss alarm relay output (1 NC contact rated for 220 VAC at 6 A \/ 30 VDC at 5 A). Front-panel diagnostic reporting is provided via a green \u003cstrong\u003ePWR OK\u003c\/strong\u003e LED. Grounded within standard Quantum backplane racks, the module provides stable internal current distribution for installed CPUs, communication modules, and I\/O slices.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible operational modes allowing standalone (11 A) or summable (up to 20 A) power expansion.\u003c\/li\u003e\n\u003cli\u003eDual AC input voltage support for 115 VAC (93...132 VAC) and 230 VAC (170...276 VAC) lines.\u003c\/li\u003e\n\u003cli\u003eIntegrated internal overvoltage and overload protective circuitry to protect internal system components.\u003c\/li\u003e\n\u003cli\u003eHardwired power-loss alarm output featuring a normally closed (NC) dry relay contact set.\u003c\/li\u003e\n\u003cli\u003eClear local diagnostic feedback via a dedicated green \u003cstrong\u003ePWR OK\u003c\/strong\u003e panel LED indicator.\u003c\/li\u003e\n\u003cli\u003eStandard Modicon Quantum backplane form factor for standard rack installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary backplane power distribution for Modicon Quantum PLC rack configurations.\u003c\/li\u003e\n\u003cli\u003eSummable power architecture in high-density, multi-module I\/O racks requiring current beyond 11 A.\u003c\/li\u003e\n\u003cli\u003eSystem monitoring interfaces utilizing the fault relay output for external mains loss reporting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct \/ Component Type\u003c\/td\u003e\n\u003ctd\u003ePower supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Type\u003c\/td\u003e\n\u003ctd\u003eSummable or standalone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e115 VAC (93...132 VAC, 47...63 Hz) \/ 230 VAC (170...276 VAC, 47...63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e1300 mA at 115 V \/ 750 mA at 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e19 A at 230 V \/ 38 A at 115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e130 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Output Current\u003c\/td\u003e\n\u003ctd\u003e11 A at 60 degC (Standalone) \/ 20 A at 60 degC (Summable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 % of fundamental rms value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e2 A, slow-blow (Modicon 57-00089-000 or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e6 + (1.5 x Iout) where Iout is in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003e1 NC relay (6 A at 220 VAC \/ 5 A at 30 VDC power supply fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eInternal overvoltage and output overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e1 green LED (PWR OK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard Quantum rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg (1.43 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature for Operation\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature for Storage\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m (16404.2 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePower Loss Alarm Relay Output (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePower Loss Alarm Relay Output (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eVoltage Selection Jumper Terminal (Install jumper for 115 VAC only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eVoltage Selection Jumper Terminal (Install jumper for 115 VAC only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eAC Line Input (AC L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eAC Neutral Input (AC N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eProtective Earth Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the system main power is disconnected prior to inserting or removing the power supply from the Quantum backplane.\u003c\/li\u003e\n\u003cli\u003eConfirm input line voltage settings; ensure terminal pins 3 and 4 have a jumper installed for 115 VAC operation, or leave open for 230 VAC operation.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the dedicated slot in the Quantum rack and seat it firmly into the backplane connector.\u003c\/li\u003e\n\u003cli\u003eWire the AC mains supply to terminal 5 (AC L) and terminal 6 (AC N), and attach the protective grounding line to terminal 7.\u003c\/li\u003e\n\u003cli\u003eIf auxiliary monitoring is required, wire external alarm loops through the NC dry relay contacts on terminals 1 and 2.\u003c\/li\u003e\n\u003cli\u003eVerify that an external 2.0 A slow-blow fuse is installed in the line circuit prior to energizing the module.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSummable Operation Compatibility:\u003c\/strong\u003e Combine only approved AC summable power supply models (such as 140CPS11420 or 140CPS11410) within the same backplane rack. Do not mix AC power supplies with DC models (e.g., 214 00 or 414 00) in summable configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Power Calculations:\u003c\/strong\u003e Note that legacy programming software (such as ProWORX NxT versions prior to v2.2 SR8) may calculate power consumption incorrectly for 11 A modules. Calculate backplane power totals manually when configuring racks in legacy software environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Procedure:\u003c\/strong\u003e When replacing a failed module, power down the rack feed, disconnect the 7-point terminal connector, release the top\/bottom rack seating levers, replace the hardware, and reconnect the terminal block without altering cabinet field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCertification \/ Standard\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRating \/ Compliance Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL 508, CSA C22.2 No 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarkings \/ Product Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, cUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic Discharge Resistance\u003c\/td\u003e\n\u003ctd\u003e4 kV contact \/ 8 kV air conforming to IEC 801-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Field Resistance\u003c\/td\u003e\n\u003ctd\u003e9.1 V\/m (10 V\/m) 80...2000 MHz conforming to IEC 801-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104496116075,"sku":"140CPS11420","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140cps11420-imle4q1uohh.png?v=1776159490","url":"https:\/\/www.plcprotech.com\/it\/products\/schneider-electric-modicon-quantum-140cps11420-ac-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}