{"product_id":"abb-pstx840-600-70-1sfa898119r7000-softstarter","title":"ABB PSTX840-600-70 1SFA898119R7000 Softstarter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003ePSTX840-600-70\u003c\/strong\u003e (product ID \u003cstrong\u003e1SFA898119R7000\u003c\/strong\u003e \/ \u003cstrong\u003e1SFA 8981 19 R7000\u003c\/strong\u003e) is a three-phase \u003cstrong\u003ePSTX series softstarter\u003c\/strong\u003e engineered for controlled starting, stopping, and protection of medium- to large-sized three-phase AC induction motors. Operating across a main circuit voltage range of \u003cstrong\u003e208 to 600 V AC\u003c\/strong\u003e at \u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e with a \u003cstrong\u003e100 to 250 V AC\u003c\/strong\u003e control supply, the unit delivers a rated operational current of \u003cstrong\u003e840 A\u003c\/strong\u003e in an in-line connection (\u003cstrong\u003e250 kW at 230 V\u003c\/strong\u003e, \u003cstrong\u003e450 kW at 400 V\u003c\/strong\u003e, and \u003cstrong\u003e600 kW at 500 V\u003c\/strong\u003e) or \u003cstrong\u003e1455 A\u003c\/strong\u003e in an inside-delta connection (\u003cstrong\u003e450 kW at 230 V\u003c\/strong\u003e, \u003cstrong\u003e800 kW at 400 V\u003c\/strong\u003e, and \u003cstrong\u003e1000 kW at 500 V\u003c\/strong\u003e).\u003c\/p\u003e\n\u003cp\u003eEquipped with three-phase voltage-ramp and torque-control algorithms, the \u003cstrong\u003ePSTX840-600-70\u003c\/strong\u003e integrates a \u003cstrong\u003ebuilt-in bypass\u003c\/strong\u003e contactor to minimize power losses during continuous running and simplify panel wiring. Operators interact via a \u003cstrong\u003edetachable full-graphic display\u003c\/strong\u003e rated \u003cstrong\u003eIP66\u003c\/strong\u003e and \u003cstrong\u003eUL Type 4X\u003c\/strong\u003e for outdoor panel mounting, while system integration is supported through hardwired Start\/Stop\/Reset inputs, three programmable digital inputs, four signaling relays, an analog output (\u003cstrong\u003e0 to 10 V\u003c\/strong\u003e, \u003cstrong\u003e0 to 20 mA\u003c\/strong\u003e, or \u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e), \u003cstrong\u003ebuilt-in Modbus RTU\u003c\/strong\u003e, and optional \u003cstrong\u003eAnybus\u003c\/strong\u003e communication modules.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase motor control supporting soft start and soft stop via voltage ramp or torque control\u003c\/li\u003e\n\u003cli\u003eBuilt-in bypass for reduced heat dissipation, energy savings, and simplified cabinet installation\u003c\/li\u003e\n\u003cli\u003eHigh current capacity rated at 840 A in-line and 1455 A inside-delta with a starting capacity of 4 x Ie for 10 seconds\u003c\/li\u003e\n\u003cli\u003eDetachable full-graphic HMI display with IP66 and UL Type 4X outdoor environmental rating\u003c\/li\u003e\n\u003cli\u003eBuilt-in electronic overload protection (EOL) with dual overload curves for start and run phases\u003c\/li\u003e\n\u003cli\u003eAdvanced motor control modes including kickstart, forward\/reverse slow-speed jog, dynamic braking, standstill brake, pump cleaning, motor heating, sequence start, emergency\/fire pump mode, and two-phase limp mode\u003c\/li\u003e\n\u003cli\u003eComprehensive electrical and thermal protection covering phase reversal, current\/voltage imbalance, underload, locked rotor, ground fault, thyristor overload, and PTC\/PT-100 temperature inputs\u003c\/li\u003e\n\u003cli\u003eBuilt-in Modbus RTU communication plus support for optional Anybus modules (Profinet, Profibus, Modbus TCP, EtherNet\/IP, EtherCAT, DeviceNet, CANopen, BACnet-IP, and BACnet-MSTP)\u003c\/li\u003e\n\u003cli\u003eFour integrated status signaling relays (Run, By-pass\/TOR, Fault, Overload) and configurable analog output (0 to 10 V, 0 to 20 mA, 4 to 20 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal and positive-displacement pumps, including municipal water systems and emergency\/fire pump installations\u003c\/li\u003e\n\u003cli\u003eIndustrial ventilation fans, exhaust blowers, and HVAC air handling units\u003c\/li\u003e\n\u003cli\u003eRotary screw, reciprocating, and centrifugal air and gas compressors\u003c\/li\u003e\n\u003cli\u003eHeavy-duty belt conveyors, crushers, and bulk material handling systems\u003c\/li\u003e\n\u003cli\u003eHigh-inertia three-phase industrial machinery operating on 208 to 600 V AC mains\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Type Designation\u003c\/td\u003e\n\u003ctd\u003ePSTX840-600-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e1SFA898119R7000 \/ 1SFA 8981 19 R7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e7320500510421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePSTX Softstarters (PSTX840)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThree-Phase Softstarter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e208 to 600 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (Main Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Control Supply Voltage (Us)\u003c\/td\u003e\n\u003ctd\u003e100 to 250 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Control Circuit Voltage (Uc)\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current - In-Line (Ie)\u003c\/td\u003e\n\u003ctd\u003e840 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Power - In-Line (Pe)\u003c\/td\u003e\n\u003ctd\u003e250 kW (at 230 V); 450 kW (at 400 V); 600 kW (at 500 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current - Inside Delta\u003c\/td\u003e\n\u003ctd\u003e1455 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Power - Inside Delta\u003c\/td\u003e\n\u003ctd\u003e450 kW (at 230 V); 800 kW (at 400 V); 1000 kW (at 500 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/CSA Horsepower Rating (Three-Phase)\u003c\/td\u003e\n\u003ctd\u003e300 Hp (200 to 208 V AC); 350 Hp (220 to 240 V AC); 700 Hp (440 to 480 V AC); 800 Hp (550 to 600 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Voltage (UL\/CSA)\u003c\/td\u003e\n\u003ctd\u003e600 V (Main Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Factor\u003c\/td\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Capacity at Maximum Rated Current (Ie)\u003c\/td\u003e\n\u003ctd\u003e4 x Ie for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Time\u003c\/td\u003e\n\u003ctd\u003e1 to 120 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Voltage During Start\u003c\/td\u003e\n\u003ctd\u003e10 to 99 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Down Voltage Special Ramp\u003c\/td\u003e\n\u003ctd\u003e100 to 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limit Function\u003c\/td\u003e\n\u003ctd\u003e1.5 to 7.5 x Ie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Bypass\u003c\/td\u003e\n\u003ctd\u003eYes (with Inside Delta connection switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eBuilt-in electronic overload protection (EOL), dual overload (start and run)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Relays\u003c\/td\u003e\n\u003ctd\u003eRun Signal Relay, By-pass (TOR) Signal Relay, Fault Signal Relay, Overload Signal Relay (NO contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V, 0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Status Indicators\u003c\/td\u003e\n\u003ctd\u003eReady to Start\/Standby ON (Green), Running R (Green), Protection (Yellow), Fault (Red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus-RTU (built-in); Modbus-TCP, EtherNet\/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, BACnet-MSTP (via Anybus \/ Fieldbus plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMI Display\u003c\/td\u003e\n\u003ctd\u003eDetachable full-graphic display (IP66 and UL Type 4X outdoor rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Circuit Terminal Type\u003c\/td\u003e\n\u003ctd\u003eBusbars (Bars)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque (Main Circuit)\u003c\/td\u003e\n\u003ctd\u003e45 N-m (398.3 lb-in UL\/CSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnecting Capacity (Control \u0026amp; Supply Circuits)\u003c\/td\u003e\n\u003ctd\u003eRigid 1 x 2.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eMain Terminals: IP00 (IEC 60529, IEC 60947-1, EN 60529); Graphic Display: IP66 \/ Type 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e435 mm x 493 mm x 369 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e46.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Package Dimensions \u0026amp; Gross Weight\u003c\/td\u003e\n\u003ctd\u003e600 mm (W) x 616 mm (D) x 800 mm (H); 58.5 kg gross weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Power Busbars\u003c\/td\u003e\n\u003ctd\u003eThree-phase line and motor load busbar connections rated up to 840 A in-line (1455 A inside-delta), tightened to 45 N-m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Supply Terminals (Us)\u003c\/td\u003e\n\u003ctd\u003e100 to 250 V AC (50\/60 Hz) auxiliary control power input accepting rigid 1 x 2.5 mm2 conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit \u0026amp; Digital Inputs (Uc)\u003c\/td\u003e\n\u003ctd\u003e24 V DC control circuit with hardwired Start, Stop, Fault Reset, and three programmable digital inputs (rigid 1 x 2.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Relays\u003c\/td\u003e\n\u003ctd\u003eNormally Open (NO) relay outputs for Run, By-pass \/ Top of Ramp (TOR), Fault, and Overload status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Terminals\u003c\/td\u003e\n\u003ctd\u003eConfigurable analog feedback output supporting 0 to 10 V, 0 to 20 mA, or 4 to 20 mA signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor Inputs\u003c\/td\u003e\n\u003ctd\u003eDedicated motor thermal protection inputs supporting PTC and PT-100 sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Fieldbus Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated Modbus RTU serial communication interface and external Fieldbus plug adaptor support (PS-FBPA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnybus \u0026amp; HMI Expansion Ports\u003c\/td\u003e\n\u003ctd\u003eFront expansion slot for optional Anybus industrial Ethernet\/fieldbus modules and port for the detachable IP66 graphic display or PSCA-1 USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Protection: Because the main power terminals carry an IP00 protection rating, install the softstarter inside a suitable industrial control enclosure; optionally fit terminal shrouds (LT750-AC \/ LT750-AL) and terminal enlargements (LW750) or CuAl cable lug kits (1SDA013956R1 \/ 1SDA023380R1) for finger protection and conductor termination.\u003c\/li\u003e\n\u003cli\u003eBusbar \u0026amp; Control Wiring Torque: Tighten main circuit busbar connections to 45 N-m (398.3 lb-in per UL\/CSA specifications) and terminate control\/supply wiring using rigid 1 x 2.5 mm2 conductors.\u003c\/li\u003e\n\u003cli\u003eConnection Configuration: Select between standard in-line connection (up to 840 A) and inside-delta connection (up to 1455 A) using the integrated inside-delta configuration switch prior to commissioning.\u003c\/li\u003e\n\u003cli\u003eRemote HMI Mounting: Detach the IP66 \/ Type 4X rated graphic display from the softstarter body and mount it on the cabinet door for external operator access and diagnostics without opening the enclosure.\u003c\/li\u003e\n\u003cli\u003eThermal Clearance \u0026amp; Operating Environment: Maintain ambient air temperatures within -25 to +60 degC inside the panel during operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE: Compliant with European Union directives (Declaration of Conformity 2CMT005209)\u003c\/li\u003e\n\u003cli\u003eUL \/ cULus: Rated for UL\/CSA three-phase motor control up to 600 V AC and 800 Hp\u003c\/li\u003e\n\u003cli\u003eCCC and CQC: Certified under China Compulsory Certification (2020980304001095 \/ 2020980304001491) and CQC (CQC2015010304830300 \/ CQC2015010304830295)\u003c\/li\u003e\n\u003cli\u003eDNV: Marine and offshore type approval certificate TAE000087N\u003c\/li\u003e\n\u003cli\u003eRoHS and REACH: Compliant with EU RoHS Directive 2011\/65\/EU and Amendment 2015\/863 (2CMT2022-006500), EU REACH (2CMT2022-006481), and US TSCA (2CMT2023-006524)\u003c\/li\u003e\n\u003cli\u003eEnvironmental \u0026amp; Data Compliance: ABB EcoSolutions validated with 81.9% recyclability per EN 45555, WEEE Category 5 B2B compliance, and EU Data Act compliance (1SFC132498M0201)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":54578571510123,"sku":"1SFA898119R7000","price":9000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PSTX840-600-70_001_1200x1200_a7da2182-3d00-4205-ad7b-ea102c8e6aa4.jpg?v=1795700011","url":"https:\/\/www.plcprotech.com\/kk\/products\/abb-pstx840-600-70-1sfa898119r7000-softstarter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}