{"product_id":"bently-nevada-126599-01-3500-44m-aero-gt-i-o-module","title":"Bently Nevada 126599-01 3500\/44M Aero GT I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e126599-01\u003c\/strong\u003e is an Aero GT I\/O module with internal terminations manufactured by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for the 3500\/44M Aeroderivitive GT Vibration Monitor. Installed in a full-height rear slot of a 3500 rack, the \u003cstrong\u003e126599-01\u003c\/strong\u003e accepts input signals from interface modules (part numbers 86517 and 86497), Velomitors, and accelerometers to monitor aeroderivative gas turbine machinery. The module operates in conjunction with the 3500\/44M main monitor module, accepting inputs from two separate Keyphasor signals and routing signals for 1X vibration tracking, band-pass vibration, and signal integration. It includes internal termination connections for transducer inputs, recorder outputs, and inhibit controls.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull-height rear I\/O module with internal termination wiring headers\u003c\/li\u003e\n\u003cli\u003eInterfaces with interface modules (PN 86517 and 86497), Velomitors, and accelerometers\u003c\/li\u003e\n\u003cli\u003eRoutes input signals for aeroderivative gas turbine monitoring applications\u003c\/li\u003e\n\u003cli\u003eSupports dual Keyphasor signal inputs across channel pairs\u003c\/li\u003e\n\u003cli\u003eConnects directly to the 3500\/44M Aeroderivitive GT Vibration Monitor main board via the rack backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAeroderivative gas turbine vibration monitoring\u003c\/li\u003e\n\u003cli\u003eMachinery protection and automated alarm trip systems\u003c\/li\u003e\n\u003cli\u003eIndustrial gas turbine condition monitoring loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Option\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/44-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAeroderivative Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Hazardous Area Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003ecNRTLus (Class 1, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX\/IECEx\/CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares \u0026amp; Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e126599-01\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e143490-01\u003c\/td\u003e\n\u003ctd\u003e3500\/44M Aeroderivitive GT Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e143491-01\u003c\/td\u003e\n\u003ctd\u003e3500\/44M Aeroderivitive GT Vibration Monitor User Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140471-01\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140482-01\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e169459-01\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e169459-02\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00580434\u003c\/td\u003e\n\u003ctd\u003eEuro Style connector header, 8 pin, Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00580432\u003c\/td\u003e\n\u003ctd\u003eEuro Style connector header, 10 pin, Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00561941\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom and Multimode Prox\/Velom I\/O Module ten-pin connector shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e166M2389\u003c\/td\u003e\n\u003ctd\u003eConnector Header Push-in-Spring Type (Alternative for PN 00580434)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e166M2388\u003c\/td\u003e\n\u003ctd\u003eConnector Header Push-in-Spring Type (Alternative for PN 00580432)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 4 signals from interface modules (86517, 86497), Velomitors, and accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreater than 95 kOhm (Proximitor and acceleration inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-23 Vdc nominal at 43 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Voltage Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA (Output proportional to monitor full-scale; load resistance 0 to 600 Ohm, +12 Vdc range across load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR +\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR -\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHLD\u003c\/td\u003e\n\u003ctd\u003eTransducer Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH1 - CH4\u003c\/td\u003e\n\u003ctd\u003eChannel 1 through Channel 4 Transducer Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINHB\u003c\/td\u003e\n\u003ctd\u003eInhibit Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRET\u003c\/td\u003e\n\u003ctd\u003eReturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREC1 - REC4\u003c\/td\u003e\n\u003ctd\u003eRecorder Outputs 1 through 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHIELD\u003c\/td\u003e\n\u003ctd\u003eSystem Ground \/ Shield Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module into the full-height rear slot directly behind the 3500\/44M main monitor board.\u003c\/li\u003e\n\u003cli\u003eSecure field transducer and recorder wiring using compatible Euro-style connector headers or push-in spring terminal connectors.\u003c\/li\u003e\n\u003cli\u003eConnect channel shield wires to the designated SHLD terminals on the I\/O block.\u003c\/li\u003e\n\u003cli\u003eEnsure proper insertion and torque on rear panel retaining screws to secure backplane ground connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC\u003c\/strong\u003e: Complies with part 15 of the FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC\u003c\/strong\u003e: European Community Directive 2014\/30\/EU; Standards EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e: European Community Directive LV Directive 2014\/35\/EU; Standard EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS\u003c\/strong\u003e: European Community Directive ROHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime\u003c\/strong\u003e: DNV GL rules for classification; ABS Rules for Condition of Classification (Part 1, Steel Vessels Rules, Offshore Units and Structures)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus (Without Internal Barriers)\u003c\/strong\u003e: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus (With Internal Barriers)\u003c\/strong\u003e: Class I, Zone 2: AEx\/Ex nA nC ic [ia Ga] IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic [ia Ga] IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (W\/ IS Output for Division 1); T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Without Internal Barriers)\u003c\/strong\u003e: Ex II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (With Internal Barriers)\u003c\/strong\u003e: Ex II (1) G; Ex nA nC ic [ia Ga] IIC T4 Gc; Ex ec nC ic [ia Ga] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666854769003,"sku":"126599-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-126599-01-aero-gt-i-o-module-dj13igkyjdd_d5a289e7-dadc-46da-9523-073c47c97f8f.jpg?v=1765449147","url":"https:\/\/www.plcprotech.com\/kk\/products\/bently-nevada-126599-01-3500-44m-aero-gt-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}