{"product_id":"bently-nevada-3500-04-01-136719-01-earthing-i-o-module","title":"Bently Nevada 3500\/04-01 136719-01 Earthing I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136719-01\u003c\/strong\u003e (part of the \u003cstrong\u003e3500\/04-01\u003c\/strong\u003e assembly) is an Earthing I\/O Module designed for intrinsically safe (IS) ground reference management within the 3500 Machinery Protection System. Installed directly into the rear of the 3500 system rack, the \u003cstrong\u003e136719-01\u003c\/strong\u003e provides the essential intrinsically safe earth connection through the 3500 system backplane to interface with internal barrier monitor I\/O modules. This configuration enables safe, direct interconnection with approved field transducers—such as 3300 XL Proximitor sensors, Velomitor sensors, thermocouples, and RTDs—operating in hazardous environments without requiring external barriers or compromising system performance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides the intrinsically safe ground connection for internal barrier I\/O modules via the 3500 system backplane.\u003c\/li\u003e\n\u003cli\u003eInstalls in a dedicated monitor position within the standard 3500 Machinery Protection System rack.\u003c\/li\u003e\n\u003cli\u003eFully integrated backplane routing eliminates the need for external zener or galvanic isolation barrier units.\u003c\/li\u003e\n\u003cli\u003eSupports combined rack layouts hosting both internal barrier modules and standard I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically safe field wiring grounding for 3500 Machinery Protection Systems in hazardous industrial areas.\u003c\/li\u003e\n\u003cli\u003eTurbomachinery vibration, speed, position, and temperature monitoring systems requiring IS loop protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Option Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/04-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/04 Internal Barrier System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e Earthing I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e None\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e North American Hazloc\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e Multi (CSA, ATEX, IECEx)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarthing I\/O Module (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e138257-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarthing Module Front Panel (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Category\u003c\/th\u003e\n\u003cth\u003eParameter \/ Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarthing I\/O Module (3500\/04 IS Earthing Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 103.1 mm (9.50 in. x 0.96 in. x 4.06 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.201 kg (0.443 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Allocation:\u003c\/strong\u003e The \u003cstrong\u003e136719-01\u003c\/strong\u003e IS Earthing Module requires a dedicated monitor position in the rack, which limits a standard 19-inch rack to 13 monitor positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning:\u003c\/strong\u003e Locate the IS Earthing Module in a rack position that allows easy access for routine online maintenance. When positioned between internal barrier I\/O modules, allow a minimum of two rack positions to facilitate online access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequirement:\u003c\/strong\u003e Any 3500 rack containing internal barrier I\/O modules must be equipped with a 3500\/04-01 IS Earthing Module to provide the backplane IS earth path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route hazardous area field wiring above the 3500 rack and safe area wiring below to maintain a minimum physical separation of 50 mm (2 in).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Approval Type\u003c\/th\u003e\n\u003cth\u003eCertificate \/ Standard Level\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with Part 15 of FCC Rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/35\/EU; EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarine Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNV GL rules for classification; ABS Rules Part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecNRTLus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666853032299,"sku":"136719-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-136719-01-earthing-i-o-module-xnvjpe1wthl_06e1e8b2-6df2-4bbe-ac6d-fe1d51d1ff8d.jpg?v=1765449103","url":"https:\/\/www.plcprotech.com\/kk\/products\/bently-nevada-3500-04-01-136719-01-earthing-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}