{"product_id":"ge-multilin-c60-k03-hkh-f8l-h67-m67-p6c-u6d-w6d-breaker-protection-system","title":"GE Multilin C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D Breaker Protection System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D\u003c\/strong\u003e is a substation-hardened protection, control, and monitoring unit designed for circuit breaker management in substation and industrial automation applications. It supports complex dual-breaker busbar configurations—such as breaker-and-a-half or ring bus schemes—and provides integrated protection functions, including breaker failure detection, multi-shot autoreclosing, synchrocheck, overcurrent, overvoltage, and sensitive directional power elements.\u003c\/p\u003e\n\u003cp\u003eEquipped with high-density I\/O configurations, advanced time synchronization, and robust communication protocol support (such as IEC 61850, DNP 3.0, Modbus TCP\/IP, and IEC 60870-5-104), the \u003cstrong\u003eGE Multilin C60K03HKHF8LH67M67P6CU6DW6D\u003c\/strong\u003e enables deterministic control logic execution and real-time visualization via an integrated color HMI panel.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Breaker Management\u003c\/strong\u003e: Complete protection, control, and monitoring in a unified modular platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Breaker Support\u003c\/strong\u003e: Native functionality for breaker-and-a-half and ring bus arrangements with internal summation of up to 4 CT sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexLogic Engine\u003c\/strong\u003e: High-speed programmable logic engine supporting up to 1024 lines of custom control schemes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Protection Elements\u003c\/strong\u003e: Includes breaker failure, 10-element synchrocheck, multi-shot autoreclosure, overvoltage, directional power, and thermal overload features.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density I\/O Flexibility\u003c\/strong\u003e: Scalable hardware architecture with selectable digital I\/O options to support wide switchyard automation needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Disturbance Recording\u003c\/strong\u003e: Advanced event recorder (1024 events), COMTRADE oscillography (up to 64 digital \/ 40 analog channels), fault summary reporting, and data logging capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstation Communication\u003c\/strong\u003e: Features advanced Ethernet options with support for IEC 61850 Ed. 1\/Ed. 2, PRP (IEC 62439-3), Routable GOOSE, IEEE 1588 time synchronization, and CyberSentry security.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHuman-Machine Interface\u003c\/strong\u003e: Graphical front panel display with user-programmable pushbuttons, status LEDs, and bay display options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStand-alone breaker monitoring and control\u003c\/li\u003e\n\u003cli\u003eBreaker-and-a-half and ring bus scheme management\u003c\/li\u003e\n\u003cli\u003eAutomatic bus transfer (main-tie-main) schemes using a single device\u003c\/li\u003e\n\u003cli\u003eDistributed bay control in utility and industrial substations\u003c\/li\u003e\n\u003cli\u003eSynchronism check and reclosing applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Code Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC60\u003c\/td\u003e\n\u003ctd\u003eFull Sized Horizontal Mount \/ Standard C60 Breaker Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003eRS485 + two 100BaseFX Eth, Multimode ST + one 10\/100BaseT Eth, RJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eEthernet Global Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eHorizontal (19\" rack) - Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003eEnhanced English Front Panel with User-Programmable Pushbuttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003e125\/250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCT\/VT DSP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF8L\u003c\/td\u003e\n\u003ctd\u003eStandard 4CT\/4VT w\/ enhanced diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61850 Process Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH67\u003c\/td\u003e\n\u003ctd\u003eNo module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital I\/O (Slot M)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM67\u003c\/td\u003e\n\u003ctd\u003e8 Form-A (No Monitoring) Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital I\/O (Slot P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP6C\u003c\/td\u003e\n\u003ctd\u003e8 Form-C Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital I\/O (Slot U)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU6D\u003c\/td\u003e\n\u003ctd\u003e16 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital I\/O (Slot W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW6D\u003c\/td\u003e\n\u003ctd\u003e16 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Grid Solutions (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMultilin UR (Universal Relay) Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eBreaker Protection System \/ Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e125\/250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCT\/VT Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Input Config\u003c\/td\u003e\n\u003ctd\u003e4 CT \/ 4 VT with Enhanced Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Input\/Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlot M Output Configuration\u003c\/td\u003e\n\u003ctd\u003e8 Form-A (No Monitoring) Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSlot P Output Configuration\u003c\/td\u003e\n\u003ctd\u003e8 Form-C Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSlot U Input Configuration\u003c\/td\u003e\n\u003ctd\u003e16 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSlot W Input Configuration\u003c\/td\u003e\n\u003ctd\u003e16 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial\u003c\/td\u003e\n\u003ctd\u003eRS485 Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFiber Ethernet\u003c\/td\u003e\n\u003ctd\u003e2x 100BaseFX (Multimode ST connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCopper Ethernet\u003c\/td\u003e\n\u003ctd\u003e1x 10\/100BaseT (RJ-45 connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSoftware Protocols\u003c\/td\u003e\n\u003ctd\u003eEthernet Global Data (EGD), Modbus, DNP 3.0, IEC protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor \u0026amp; Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eHorizontal (19-inch rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel HMI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplay \u0026amp; Controls\u003c\/td\u003e\n\u003ctd\u003eEnhanced English Front Panel with User-Programmable Pushbuttons \u0026amp; LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData \u0026amp; Event Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSequence of Events (SOE)\u003c\/td\u003e\n\u003ctd\u003eUp to 1024 time-stamped events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOscillography\u003c\/td\u003e\n\u003ctd\u003eIEEE C37.111-1999\/2013, IEC 60255-24 Ed 2.0 COMTRADE format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting\u003c\/strong\u003e: Install horizontally into a standard 19-inch rack enclosure. Ensure proper ventilation and clearance around the chassis to allow heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Connect the protective grounding lug directly to the main substation ground bus using low-impedance ground straps to minimize EMI\/RFI noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Wiring\u003c\/strong\u003e: Verify the control power supply matches the 125\/250 V AC\/DC nominal operating voltage before energizing the module. Ensure proper fusing on incoming power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT\/VT Connections\u003c\/strong\u003e: Ensure correct polarity and phase orientation when wiring current transformer and voltage transformer inputs. Never open-circuit energized CT secondary circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber-Optic Cables\u003c\/strong\u003e: Maintain recommended bend radii for ST fiber-optic Ethernet connections to prevent signal attenuation or physical fiber damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53647879537003,"sku":"C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D.jpg?v=1785635520","url":"https:\/\/www.plcprotech.com\/kk\/products\/ge-multilin-c60-k03-hkh-f8l-h67-m67-p6c-u6d-w6d-breaker-protection-system","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}