{"product_id":"ics-triplex-t8232-power-pack-28-vdc","title":"ICS Triplex T8232 Power Pack 28 Vdc","description":"\u003cp\u003eICS Triplex \u003cstrong\u003eT8232\u003c\/strong\u003e Power Pack 28 Vdc is a high-density power supply unit designed to convert main line voltages of 110 Vac or 240 Vac into adjustable 28 Vdc field power. Used as an integral component within the Trusted Power System, the \u003cstrong\u003eT8232\u003c\/strong\u003e slots into a 1U Power Shelf (T8230) to provide up to 750 W of power. The module supports hot replacement, single-wire active current sharing across parallel configurations, power factor correction, and integrated diagnostic monitoring through a Power Port connection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHot-replaceable power pack design with a physical front latch mechanism\u003c\/li\u003e\n\u003cli\u003eActive current sharing differential of +\/-3.2 A at full load\u003c\/li\u003e\n\u003cli\u003eActive power factor correction complying with IEC 61000-3-2\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection and steady-state output current limiting\u003c\/li\u003e\n\u003cli\u003eFront panel LED indicators for AC OK (green) and PWR OK (green\/amber) status\u003c\/li\u003e\n\u003cli\u003eBuilt-in ORing diode for reverse output current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed control and safety instrumented systems (SIS)\u003c\/li\u003e\n\u003cli\u003eIndustrial field power distribution\u003c\/li\u003e\n\u003cli\u003eHigh-density industrial power shelf assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICS Triplex \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT8232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Set Point ($V_{OUT}$)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current ($I_{OUT}$)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Adc to 26.78 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 Vac to 264 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 Hz to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Inrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A max (full load), \u0026lt;25 A (no load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.95 min, 0.99 typical (\u0026gt;50% of full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 mA (at 264 Vac, 50 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms (at 600 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRegulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2% to 2% (measured at remote sense)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple (20 MHz bandwidth)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mVp-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise (20 MHz bandwidth)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mVp-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 dBmc max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms to 100 ms (10% to 90% of final level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29 Vdc to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSteady State Output Current Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 Adc max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStart-up Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 s typical, 2 s max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurn-on Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 ms max (from DC on\/off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC (Derate 1.333 %\/degC from 45 degC to 50 degC; 4.667 %\/degC from 50 degC to 60 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-60 m to 3962 m (derated at 2 degC\/304 m above 2438 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 Vac (Primary to Secondary), 1500 Vac (Primary to chassis GND), 1500 Vac (Secondary to chassis GND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsertion \u0026amp; Alignment:\u003c\/strong\u003e Plug the module in slowly and smoothly into the Power Shelf slot until the first set of pins makes contact and the AC OK LED turns green. Push fully home to engage complete contact until the PWR OK LED illuminates green.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLatch Securing:\u003c\/strong\u003e Secure or release the unit using the physical latch located on the front panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Ensure unimpeded airflow through the front fans and rear vents. Maintain ambient operating temperatures within limits, taking into account required power derating above 45 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Protection:\u003c\/strong\u003e Note that a failure of an internal power pack fan will result in the automatic shutdown of the module output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approvals:\u003c\/strong\u003e UL E223750 (Power Supplies, Information Technology Equipment Including Electrical Business Equipment - Component), UL E223749 (Power Supplies, Medical and Dental - Component)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC (Conducted):\u003c\/strong\u003e CISPR22 Class B, EN 55022 Class B (with 3 dB margin)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Harmonics:\u003c\/strong\u003e IEC 61000-3-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity \u0026amp; Surge:\u003c\/strong\u003e IEC 61000-4-2 Level 3, IEC 61000-4-3 Level 2, IEC 61000-4-4 Level 3, IEC 61000-4-5 Level 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration \u0026amp; Shock:\u003c\/strong\u003e IEC 60068-2-6, IEC 60068-2-27\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53240105959787,"sku":"T8232","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ICS-Triplex-T8232-Power-Pack.jpg?v=1785643389","url":"https:\/\/www.plcprotech.com\/kk\/products\/ics-triplex-t8232-power-pack-28-vdc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}