{"product_id":"woodward-9907-963-dle-smart-pressure-transducer-manifold-assembly","title":"Woodward 9907-963 DLE Smart Pressure Transducer Manifold Assembly","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 9907-963 DLE Smart Pressure Transducer Manifold Assembly\u003c\/strong\u003e is a high-precision pressure measurement device designed for dry low emissions (DLE) turbine control systems and industrial turbomachinery. It houses multiple internal pressure transducers on a central motherboard within an aluminum manifold housing, providing precise pressure monitoring and real-time data transmission to electronic control platforms such as MicroNet, NetCon, or Atlas.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 9907-963\u003c\/strong\u003e communicates with system controller interface modules or Field Termination Modules (FTM) using standard universal asynchronous receiver transmitter (UART) protocol over RS-422 differential signaling at 375 Kbaud. Power and communication lines are routed through integrated flying leads that pass through capacitive feed-through filter assemblies to suppress electrical noise picked up from field wiring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates multiple smart pressure transducers inside a single rugged manifold assembly.\u003c\/li\u003e\n\u003cli\u003eEmploys RS-422 high-speed UART digital communication operating at 375 Kbaud.\u003c\/li\u003e\n\u003cli\u003eFeatures high-precision pressure measurement accuracy of +\/-0.047% of full scale across operating temperature ranges.\u003c\/li\u003e\n\u003cli\u003eIncludes internal capacitive feed-through filters on flying lead connections to attenuate external electrical noise.\u003c\/li\u003e\n\u003cli\u003eDesigned for remote installation up to 300 m (1000 ft) away from the field termination module.\u003c\/li\u003e\n\u003cli\u003eMaintains fast dynamic response with a 20 Hz frequency response and 6 ms latency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDry Low Emissions (DLE) gas turbine fuel and combustion control systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial turbomachinery monitoring and control platforms.\u003c\/li\u003e\n\u003cli\u003eMicroNet, NetCon, and Atlas electronic turbine control system architectures.\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy industrial process pressure monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9907-963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.047% of full scale (0 to 1000 psia \/ 0 to 69.0 bar) over operating temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits (0.015 psi \/ 0.103 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.25 W maximum per transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunications Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-422, @ 375 Kbaud (UART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Hz frequency response with 6 ms latency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverpressure Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 psia \/ 103 bar (1.5 times rated pressure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlled impedance, low capacitance shielded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Wiring (One Pair)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 AWG \/ 0.5 mm2 min if \u0026lt; 150 m (500 ft); 16 AWG \/ 1.0 mm2 min if \u0026lt; 300 m (1000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Wiring (Two Pair)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 AWG \/ 0.5 mm2 min if \u0026lt; 300 m (1000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Fittings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlareless compression fittings for 1\/4 inch stainless tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range (1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +125 degC (-40 to 257 degF) at 750 psia \/ 51.7 bar max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range (2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 to +125 degC (-31 to 257 degF) at 1000 psia \/ 69.0 bar max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+150 degC (+302 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121.69 mm x 155.55 mm x 135.79 mm (5.346 in. x 6.124 in. x 4.791 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.9 kg (8.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUS MIL-STD-810C, Figure 515.2-1 procedure 1 (20 g, 11 ms sawtooth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUS MIL-STD-810C, Figure 514.2-2 Curve J (5 g, 2 kHz) with at least a four-point mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWire \/ Lead Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e15 VDC (red)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive 15 V Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e15 GND (black)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Ground (0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eREC + (white)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReceive Data Signal Positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eREC - (black)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReceive Data Signal Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSHIELD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Shield Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eXMIT + (white)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmit Data Signal Positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eXMIT - (black)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmit Data Signal Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSAFETY GROUND (green\/yellow)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis \/ Earth Ground Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the manifold assembly in an orientation that allows condensation to drain away from the pressure inlet ports.\u003c\/li\u003e\n\u003cli\u003eEnsure pressure tubing leading from the fluid source contains no low points where condensation or contaminants can accumulate.\u003c\/li\u003e\n\u003cli\u003eKeep tubing length between the pressure source and the manifold assembly to 2.4 m (8 ft) or less for DLE system applications.\u003c\/li\u003e\n\u003cli\u003eTighten 1\/4 inch Swagelok stainless steel fittings hand-tight, then rotate 1 to 1-1\/4 turns with a wrench to seal the ferrule onto the tubing.\u003c\/li\u003e\n\u003cli\u003eApply a cover bolt torque of 9.2 N-m (81 lb-in) on flameproof \/ Zone 1 enclosures to guarantee complete enclosure sealing.\u003c\/li\u003e\n\u003cli\u003ePower input must be supplied from an isolated Class 2 power source exhibiting less than 5000 pF total capacitance from output to earth\/chassis.\u003c\/li\u003e\n\u003cli\u003eFor Class I, Division 1 or Zone 1 applications, install a conduit seal within 457 mm (18 inches) or 50 mm (2 inches) of the conduit entry, respectively.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified for Class I, Division 1, Groups C \u0026amp; D, and Class I, Division 2, Groups B, C, \u0026amp; D, T4 at 125 degC Ambient (Canada and USA). Certificate 1006295 (LR79726-5).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Directive 2014\/34\/EU:\u003c\/strong\u003e Category 2, Group IIG, Ex db IIB T4 Gb (TÜV 12 ATEX 7245 X).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKEX:\u003c\/strong\u003e S.I. 2016 No. 1107, Certificate TÜV 22UKEX7110X (Ex db IIB T4 Gb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e Certified IECEx TUR 11.0012X Ex db IIB T4 Gb.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e Declared to Directive 2014\/30\/EU and UK S.I. 2016 No. 1091 (EN 61000-6-2, EN 61000-6-4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Sealing:\u003c\/strong\u003e Tested per ANSI\/ISA 12.27.01 Single Sealing requirements (CSA test report 16584-701103164).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachinery Directive:\u003c\/strong\u003e Compliant as partly completed machinery per Directive 2006\/42\/EC and UK S.I. 2008 No. 1597.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Equipment Directive:\u003c\/strong\u003e Compliant as SEP per Article 3.3 to Directive 2014\/68\/EU.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53630973477227,"sku":"9907-963","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9907-963.jpg?v=1785419151","url":"https:\/\/www.plcprotech.com\/kk\/products\/woodward-9907-963-dle-smart-pressure-transducer-manifold-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}