{"product_id":"abb-07-dc-92-gjr5-2522-00-r0101-ac31-32-channel-digital-i-o-module","title":"ABB 07 DC 92 GJR5 2522 00 R0101 | AC31 32-Channel Digital I\/O Module","description":"\u003cp\u003e\u003cstrong\u003eABB 07 DC 92\u003c\/strong\u003e (07DC92), order number \u003cstrong\u003eGJR5 2522 00 R0101\u003c\/strong\u003e, is a remote digital input\/output module for the AC31 automation system and CS31 system bus. Unlike fixed I\/O modules, all 32 channels can be individually configured by the user program as digital inputs, digital outputs, or re-readable outputs, providing exceptional flexibility for distributed control applications.\u003c\/p\u003e\n\n\u003cp\u003eThe module divides its 32 channels into four electrically isolated groups with eight channels per group. Each output uses transistor technology with a nominal load capacity of 500 mA and incorporates electronic overload and short-circuit protection. Built-in diagnostic functions, channel status LEDs, and communication monitoring assist maintenance personnel during commissioning and fault investigation.\u003c\/p\u003e\n\n\u003cp\u003eThe ABB 07 DC 92 occupies two digital addresses on the CS31 system bus and can also be configured as a dedicated output module when input addresses are not required. This flexibility makes the module suitable for machine automation, process control systems, utility installations, and industrial modernization projects requiring distributed field I\/O.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e07 DC 92 (07DC92)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJR5 2522 00 R0101 (GJR5252200R0101)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input \/ Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC31 \/ Advant Controller 31\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCS31 System Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEIA RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Configurable Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput, Output, Re-readable Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Groups × 8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup-to-Group and Bus-to-I\/O Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 A (without load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Supply Terminal Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 W (outputs unloaded), 10 W (outputs loaded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Yellow LEDs + 1 Red Fault LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddress Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIL Switch Under Side Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eDigital Input Characteristics\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypical 7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal 0 Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 V to +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal 1 Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+13 V to +30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypical 7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference Potentials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZP0, ZP1, ZP2, ZP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eDigital Output Characteristics\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA per Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Group Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A per Group\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic Reactivation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter Short-Circuit or Overload Removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductive Load Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal Varistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation \u0026amp; Commissioning Guide\u003c\/h3\u003e\n\n\u003cp\u003eField commissioning of the ABB 07 DC 92 usually begins with verification of the DIL address switch, CS31 bus wiring, and 24 VDC power connections. The module reads its address configuration only during power-up initialization, therefore any address change requires a restart before it becomes effective.\u003c\/p\u003e\n\n\u003cp\u003eInstall the module vertically with the connectors facing upward and downward. Natural convection cooling must remain unobstructed by cable ducts, power supplies, or other cabinet components.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN EN 50022 Rail or 4 × M4 Screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNatural Convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth × Height × Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 × 140 × 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eDuring startup all LEDs illuminate briefly while the module performs initialization. If the CS31 bus is not operating correctly, the red fault LED flashes continuously. Before replacing the module, engineers should verify address settings, bus polarity, controller configuration, and cable continuity.\u003c\/p\u003e\n\n\u003cp\u003eIf an overload or short circuit occurs, the affected output channel is automatically switched off by the protection circuitry. The corresponding channel LED flashes until the fault condition is removed and the output is reactivated.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955588459,"sku":"GJR5252200R0101","price":1200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gjr5252200r0101-zovtcn43mm5_96478bd7-a123-41cb-a5d0-e70dca3b609d.jpg?v=1766478063","url":"https:\/\/www.plcprotech.com\/ms\/products\/abb-07-dc-92-gjr5-2522-00-r0101-ac31-32-channel-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}