{"product_id":"abb-1sap800100r0010-07ac91-ad2-cs31-analog-input-output-module","title":"ABB 1SAP800100R0010 07AC91-AD2 CS31 Analog Input\/Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for seamless integration into decentralized industrial automation networks, the ABB 1SAP800100R0010 serves as a highly reliable 07AC91-AD2 analog configuration input\/output module. Operating on the robust \u003cstrong\u003eCS31 fieldbus protocol\u003c\/strong\u003e, this unit facilitates high-density remote analog instrumentation handling without demanding excessive panel space. Featuring \u003cstrong\u003e8 analog inputs and 8 analog outputs\u003c\/strong\u003e with a resolution of 12 bits plus sign, it supports both voltage (U) and current (I) signals. Designed for adaptability, the hardware accommodates both 2-wire and 3-wire physical connection schemes, making it highly compatible with standard industrial sensors and transmitters.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDual-functionality module providing 8 analog inputs and 8 analog outputs.\u003c\/li\u003e\n  \u003cli\u003eFlexible parameterization for voltage and current signal ranges.\u003c\/li\u003e\n  \u003cli\u003e12-bit plus sign conversion resolution for stable measurement cycles.\u003c\/li\u003e\n  \u003cli\u003eIntegrated CS31 system bus interface for reliable distributed communication.\u003c\/li\u003e\n  \u003cli\u003eSupport for versatile 2-wire and 3-wire sensor and actuator configurations.\u003c\/li\u003e\n  \u003cli\u003ePluggable terminal blocks to simplify field wiring and quick-swap maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDistributed SCADA telemetry and PLC I\/O expansion networks.\u003c\/li\u003e\n  \u003cli\u003ePumping station control and industrial water treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eMachinery and process line control utilizing legacy CS31 fieldbus systems.\u003c\/li\u003e\n  \u003cli\u003eHVAC and environmental chamber monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOrder Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1SAP800100R0010\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e07AC91-AD2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAnalog Configuration Input\/Output Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAnalog Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8 (Configurable; Voltage\/Current)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAnalog Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8 (Configurable; Voltage\/Current)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12 bits + sign\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAuxiliary Power Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSystem Bus\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCS31 Bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWiring Types Supported\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2-wire, 3-wire\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnection Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePluggable terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.20 kg;\"\u003e0.20 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e120 mm x 80 mm x 60 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eInterface Group\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eTerminal \/ Port Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eFunctional Details\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eL+, M\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eExternal 24 VDC auxiliary power input and system ground.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCS31 Fieldbus\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBus1, Bus2, Shield\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSystem serial communication bus line and earth ground for shielding.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAnalog Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eI0+ to I7+, Common\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eChannels configured for active\/passive voltage or current loops.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAnalog Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eO0+ to O7+, Common\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eControlled voltage\/current output signals for local actuators.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 07AC91-AD2 module directly integrates with legacy AC31 master controllers and can be integrated into newer AC500 systems using an appropriate CS31 master bus module (such as the CI590 or integrated serial ports configured for CS31). Ensure that PLC configuration software contains the correct GSD or equivalent module configuration description profile matching the exact hardware index revision of the 1SAP800100R0010 to prevent system configuration mismatches during commissioning.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eCommon communication errors on the CS31 bus typically stem from incorrect bus termination or long branch lines (stubs). Ensure a 120-Ohm termination resistor is present on the physical end-points of the CS31 network. Due to the high sensitivity of 12-bit analog conversions, never route analog input cables parallel to high-voltage lines or AC motor drives without maintaining standard separation and adequate physical shielding barriers.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways configure the module's rotary address switches prior to system boot. The CS31 bus master scans address ranges on startup; dynamically changing addresses while the unit is active will cause a master CPU bus fault. Connect signal shield wires directly to the functional ground (FE) bus bar inside the control cabinet, and avoid grounding shields at both ends to eliminate the risk of destructive ground loop currents.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources before performing physical mounting, terminal connection, or address switch configuration. Failure to de-energize external 24 VDC sources and high-voltage supply lines can cause fatal electrical shock, module destruction, or erratic control loop operations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eMount the module onto a standard 35mm DIN rail, ensuring the locking mechanism is engaged and the unit is firmly seated.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eConfigure the correct CS31 station address on the module using the hardware address switches on the enclosure.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eVerify termination settings; apply a 120-Ohm resistor if this module occupies the physical end of the CS31 bus segment.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eWire the analog inputs and outputs using shielded, twisted-pair cables according to your 2-wire or 3-wire signal configuration.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003ePower up the 24 VDC auxiliary line and confirm that the module's status LEDs indicate a successful bus communication handshake.\u003c\/span\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955817835,"sku":"1SAP800100R0010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1sap800100r0010-wd1kbniqqs1_76410548-b40a-4572-afac-51fa3fd46874.jpg?v=1766478070","url":"https:\/\/www.plcprotech.com\/ms\/products\/abb-1sap800100r0010-07ac91-ad2-cs31-analog-input-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}