{"product_id":"abb-imcpm02-bailey-infi-90-communication-port-module","title":"ABB IMCPM02 Bailey infi 90 Modul Port Komunikasi","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB IMCPM02\u003c\/strong\u003e is a microprocessor-based single-slot wide interface module designed for the INFI 90 system. This device connects the CTT02 Configuration and Tuning Terminal and\/or an engineering work station (EWS) to a single INFI 90 process control unit (PCU). It provides a local, reliable interface within the PCU for comprehensive system configuration, tuning, and diagnostics. The \u003cstrong\u003eIMCPM02\u003c\/strong\u003e enables operators to configure, tune, and monitor master modules alongside their respective function blocks. It features direct compatibility with existing Network 90 and INFI 90 systems, serving as a functional replacement for the IMSPM01 Serial Port Module and IMCPM01 Configuration Port Module. The module operates efficiently across PCUs utilizing either a module bus or Controlway architecture.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor-driven architecture occupying a single slot within a standard module mounting unit (MMU).\u003c\/li\u003e\n\u003cli\u003eDual-interface capability supporting both a handheld configuration tuning terminal (CTT) and an engineering work station (EWS) to minimize physical hardware footprints.\u003c\/li\u003e\n\u003cli\u003eComprehensive diagnostic interface featuring one dual-color (red\/green) status LED and eight dedicated red error status LEDs.\u003c\/li\u003e\n\u003cli\u003eTwo onboard eight-pole dipswitches for setting the Controlway\/module bus address, configuring baud rates, and enabling specialized diagnostic routines.\u003c\/li\u003e\n\u003cli\u003eFront panel reset switch accessible directly through the faceplate window for manual module initialization.\u003c\/li\u003e\n\u003cli\u003eFlexible jumper array designed to select between DTE, DCE, or loopback operating modes for the EWS serial port.\u003c\/li\u003e\n\u003cli\u003eExpandable installation options accommodating permanent mounting configurations via a dedicated termination module or unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocal system tuning, parameter adjustment, and configuration of master modules in INFI 90 process control units.\u003c\/li\u003e\n\u003cli\u003eReal-time diagnostic verification and communication testing across intelligent DCS components.\u003c\/li\u003e\n\u003cli\u003eIndustrial process automation environments requiring a direct serial interface for work station integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule, communication port module\u003c\/td\u003e\n\u003ctd\u003eIMCPM02\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination module, multi-function processor\u003c\/td\u003e\n\u003ctd\u003eNIMP01\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination unit, multi-function processor\u003c\/td\u003e\n\u003ctd\u003eNTMP01\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable, IMCPM02 to termination unit\u003c\/td\u003e\n\u003ctd\u003eNKTU01\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable, IMCPM02 to termination module\u003c\/td\u003e\n\u003ctd\u003eNKTU02\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProperty\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCharacteristics\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.81 A maximum, 750 mA typical, at +5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.1 W maximum, 3.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd\u003e32 bit processor (16 bit external bus) running at 16 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e128 kbytes of ROM, 256 kbytes of RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e1 - isolated RS-232-C at up to 19.2 kbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +70 degC (32 to 158 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90% R.H. up to 55 degC (131 Fahrenheit) (noncondensing), 5% to 40% R.H. at 70 degC (158 Fahrenheit) (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km (1.86 mi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP1\u003c\/td\u003e\n\u003ctd\u003ePower \/ Module Bus \/ Controlway Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP3\u003c\/td\u003e\n\u003ctd\u003eInput \/ Output Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP4\u003c\/td\u003e\n\u003ctd\u003eCTT Port (5-Pin Round Connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP5\u003c\/td\u003e\n\u003ctd\u003eEWS Port (DB-25 Connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP6\u003c\/td\u003e\n\u003ctd\u003eUtility Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the MMU backplane voltages before installing the module; ensure that older system configurations applying -30 VDC are isolated or that jumper J12 is properly configured to avoid potential equipment damage.\u003c\/li\u003e\n\u003cli\u003eSet jumper J12 to short pins 2 and 3 if the module is deployed in a standard INFI 90 system to enable redundant Controlway bus operations.\u003c\/li\u003e\n\u003cli\u003eAlign the circuit board with the top and bottom guide rails of the module mounting unit slot, sliding the module backward until it sits firmly within the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eTighten the two front concentric faceplate screws by turning them 1\/2 turn clockwise to lock the assembly into place.\u003c\/li\u003e\n\u003cli\u003eFor remote or permanent wiring terminations, route the appropriate NKTU01 or NKTU02 cable from the backplane to the corresponding NIMP01 termination module or NTMP01 termination unit.\u003c\/li\u003e\n\u003cli\u003eEnsure cabinet power is entirely disconnected before initiating any external termination unit or module wiring procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA certified for use as process control equipment in ordinary (non-hazardous) locations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668622897515,"sku":"IMCPM02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-imcpm02-communication-port-module-bucvh0vjc3k_822d0d75-5d92-42a8-8f7a-172ad7d9e24e.jpg?v=1765535877","url":"https:\/\/www.plcprotech.com\/ms\/products\/abb-imcpm02-bailey-infi-90-communication-port-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}