{"product_id":"abb-sphss13-s-turbine-hydraulic-servo-module","title":"ABB SPHSS13 S+ Turbine Hydraulic Servo Module","description":"\u003cp style=\"color: #2d3748;\"\u003eThe ABB \u003cstrong\u003eSPHSS13 \u003c\/strong\u003eis a high-reliability hardware component engineered for closed-loop valve positioning and loop regulation within Symphony Plus systems. This unit regulates fluid flow or pressure variables to drive main steam valves, intercept valves, or governing actuators based on immediate turbine speed and load reference demands. By executing dedicated servo-loop control algorithms independently, the module maintains tight dynamic response loops and reduces critical processor bus constraints across the backplane architecture during sudden load rejections or transient grid fluctuations. This module serves as the direct current-generation replacement for the legacy \u003ca style=\"color: #2b6cb0; text-decoration: underline;\" href=\"https:\/\/www.plcprotech.com\/products\/abb-sphss03-s-turbine-hydraulic-servo-module\" title=\"ABB SPHSS03\"\u003eABB SPHSS03\u003c\/a\u003e module, providing identical mechanical form-factor drop-in compatibility alongside upgraded signal reliability tolerances.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Coil Architecture:\u003c\/strong\u003e Equipped to interface with redundant servo coils to maintain live actuation lines if a primary channel faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile LVDT Feedback Processing:\u003c\/strong\u003e Natively accepts feedback signals from either redundant AC or redundant DC Linear Variable Differential Transducers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymmetry Plus Integration:\u003c\/strong\u003e Fully compatible with standard S+ Turbine backplanes and Distributed Control Unit frameworks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eManaging redundant servo loop control on main steam or reheat control valves within power generation facilities.\u003c\/li\u003e\n\u003cli\u003eUpgrading older control topologies utilizing legacy cards to modern, fault-tolerant standards.\u003c\/li\u003e\n\u003cli\u003eCritical positioning of hydraulic governor systems in heavy industrial turbine applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n\u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eS+ Turbine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eSPHSS13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShort Description\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHYDRAULIC SERVO MODULE - RED SERVO LVDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTechnical Information\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eRedundant servo coils, Redundant AC or DC LVDT feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePart Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e8538908180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eIndia (IN) \/ Malta (MT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e360 x 280 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n\u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all control system power and completely depressurize the field hydraulic fluid lines prior to performing card insertion or removal. Failure to isolate the hydraulic actuation loops may result in unintended valve travel, machine damage, or severe personnel injury.\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eVerify hardware jumpers and software-configured options match the specific AC or DC LVDT feedback instrumentation architecture deployed on the hydraulic cylinder before sliding the card into the slot tracks.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eEnsure the subrack backplane is free of contaminants and slide the assembly vertical tracks firmly into place until the rear connectors sit entirely square inside the bus interface socket.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eTerminate all dual servo coil drive cables and high-frequency LVDT sensor signal shields cleanly at the designated termination block to suppress industrial EMI\/RFI noise cross-coupling.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668611920235,"sku":"SPHSS13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-sphss03-dcu-hydraulic-servo-module-052okjcxsso_90b773b3-e602-47b9-ba4f-22cf2f021966.jpg?v=1765535522","url":"https:\/\/www.plcprotech.com\/ms\/products\/abb-sphss13-s-turbine-hydraulic-servo-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}