{"product_id":"allen-bradley-1756-enbt-controllogix-ethernet-ip-bridge-module","title":"Modul Jambatan EtherNet\/IP ControlLogix Allen-Bradley 1756-ENBT","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1756-ENBT\u003c\/strong\u003e is a chassis-based industrial communication module engineered for the \u003cstrong\u003eControlLogix\u003c\/strong\u003e hardware architecture. It functions as a dedicated bridge link between localized automation infrastructure and macro-level plant networks, handling explicit messaging and real-time distributed data transfers over EtherNet\/IP links. Incorporating 1 standard copper RJ45 socket that handles 10\/100 Mbps communication rates over Category 5 network infrastructure, the \u003cstrong\u003e1756-ENBT\u003c\/strong\u003e supports 64 TCP\/IP connections alongside up to 128 simultaneous CIP connections to execute multi-node monitoring and distributed standard remote IO interfaces.\u003c\/p\u003e\n\u003cp\u003eEmploying a standardized open-style enclosure rated to occupy a single slot width inside any standard hardware rack, this communication module uses producer-consumer networking mechanisms to facilitate seamless data distribution across multiple distributed system controllers. Field personnel can perform diagnostic assessments directly via the onboard front digital indicator panel. The circuit framework provides up to 30V continuous operational isolation between the physical network cabling and the backplane logic components to insulate internal automation architectures against transient external electrical surges.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBridges Control Network Architectures:\u003c\/strong\u003e Provides a specialized communication interface linking upstream factory networking layers with standard remote I\/O sub-assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Connection Topologies:\u003c\/strong\u003e Features dual capability with support for a maximum of 64 TCP\/IP connections alongside 128 physical CIP connection configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Hardware Diagnostics:\u003c\/strong\u003e Front-mounted localized digital indicators simplify system verification by reporting live hardware states and communication errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Media Support:\u003c\/strong\u003e Built with a standard 10\/100 Mbps copper RJ45 port compatible with shielded or unshielded category 5 twisted-pair media lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote I\/O station integration and localized distributed control rack telemetry.\u003c\/li\u003e\n\u003cli\u003eStandardized supervisory control and real-time plant data management links.\u003c\/li\u003e\n\u003cli\u003eInter-chassis processor logic sharing and machine-to-machine data synchronization.\u003c\/li\u003e\n\u003cli\u003eVariable frequency drive monitoring and integrated remote peripheral instrumentation data paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-ENBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSub Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Copper RJ45 (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections Supported (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP: 64, CIP: 128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCIP Unconnected Messages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 + 64 (backplane + Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700mA @ 5.1V DC, 3mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.6 btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30V (continuous), basic insulation type, Ethernet network to backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to 60 Celsius (32 Fahrenheit to 140 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to 85 Celsius (-40 Fahrenheit to 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 G @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Operating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet RJ45 Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory 5 shielded or unshielded twisted pair network connection interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the circuit board edge with the top and bottom channel guides of a free rack slot inside the target chassis. Push firmly inward until the securing mechanism locks completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Media Routing:\u003c\/strong\u003e Secure the 802.3 compliant Category 5 Ethernet cable to the front RJ45 port. Implement appropriate cable management bends to avoid mechanical tension on the port assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Mitigation and Separation:\u003c\/strong\u003e Keep network lines segregated from motor supply leads and high-power AC conductors within the industrial cabinet to mitigate localized electromagnetic induction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Cleanliness:\u003c\/strong\u003e Since the unit utilizes an open-style open-style chassis configuration, maintain ambient surrounding temperatures below 60 Celsius and guard against conductive foreign debris.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eChina CCC\u003c\/li\u003e\n\u003cli\u003eAustralian RCM\u003c\/li\u003e\n\u003cli\u003eAmerican Bureau of Shipping\u003c\/li\u003e\n\u003cli\u003eSemiconductor Inds Immunit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOfficial Product Documentation\u003c\/h3\u003e\n\u003cp\u003eAccess and download the official Allen-Bradley manufacturer publications for this module:\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; min-width: 500px; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; font-size: 14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color: #f8f9fa; border-bottom: 2px solid #dee2e6; text-align: left;\"\u003e\n        \u003cth style=\"padding: 12px; font-weight: 600; color: #333;\"\u003eDocument Title \/ Type\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; font-weight: 600; color: #333;\"\u003ePublication Number\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; font-weight: 600; color: #333; text-align: right;\"\u003eAction\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #dee2e6;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: 500; color: #212529;\"\u003eControlLogix Communication Modules Technical Data\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #495057;\"\u003e1756-TD003\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; text-align: right;\"\u003e\n          \u003ca href=\"https:\/\/www.plcprotech.com\/cdn\/shop\/files\/1756-td003_-en-e_72b548d8-1701-4bf6-8a4a-d18b11f31b95.pdf?v=1783057783\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: 500;\"\u003eDownload PDF ↗\u003c\/a\u003e\n        \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #dee2e6;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: 500; color: #212529;\"\u003eControlLogix EtherNet\/IP Bridge Module Installation Instructions\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #495057;\"\u003e1756-IN019\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; text-align: right;\"\u003e\n          \u003ca href=\"https:\/\/www.plcprotech.com\/cdn\/shop\/files\/1756-in019_-en-p.pdf?v=1783057844\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: 500;\"\u003eDownload PDF ↗\u003c\/a\u003e\n        \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #dee2e6;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: 500; color: #212529;\"\u003eControlLogix 5580 and 5570 Systems Selection Guide\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #495057;\"\u003e1756-SG001\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; text-align: right;\"\u003e\n          \u003ca href=\"https:\/\/www.plcprotech.com\/cdn\/shop\/files\/1756-sg002_-en-p.pdf?v=1783057951\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: 500;\"\u003eDownload PDF ↗\u003c\/a\u003e\n        \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #dee2e6;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: 500; color: #212529;\"\u003eControlLogix 5580 Controllers Product Profile\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #495057;\"\u003e--\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; text-align: right;\"\u003e\n          \u003ca href=\"https:\/\/www.plcprotech.com\/cdn\/shop\/files\/1756-pp001_-en-p.pdf?v=1783057950\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: 500;\"\u003eDownload PDF ↗\u003c\/a\u003e\n        \u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181525355,"sku":"1756-ENBT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-enbt-controllogix-enet-ip-comms-module-nwoad43j5ga_6d111120-4447-4d00-83a0-7aacafdaea06.jpg?v=1766114306","url":"https:\/\/www.plcprotech.com\/ms\/products\/allen-bradley-1756-enbt-controllogix-ethernet-ip-bridge-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}