{"product_id":"beckhoff-ep3752-0000-ethercat-box","title":"BECKHOFF EP3752-0000 EtherCAT Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegrating high-precision vibration and tilt monitoring directly into the field, the \u003cstrong\u003eBECKHOFF EP3752-0000\u003c\/strong\u003e is an IP67-rated \u003cstrong\u003eEtherCAT Box\u003c\/strong\u003e equipped with two internal 3-axis accelerometers. This module provides direct acquisition of acceleration data in three axes, eliminating the need for external accelerometer wiring in standard vibration-monitoring applications.\u003c\/p\u003e\n\n\u003cp\u003eThe EP3752-0000 enables highly flexible configuration, allowing engineering teams to program sensor measuring ranges from ±2 g up to ±16 g and select sampling rates between 200 Hz and 5 kHz. Equipped with extended digital filter functions and dedicated tilt measurement capabilities, this EtherCAT Box delivers processed signal data directly to the control system, making it an ideal choice for machinery monitoring, condition assessment, and structural tracking in harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual internal 3-axis accelerometers for comprehensive vibration and orientation monitoring.\u003c\/li\u003e\n  \u003cli\u003eProgrammable sensor measuring range of ±2 g, ±4 g, ±8 g, or ±16 g.\u003c\/li\u003e\n  \u003cli\u003eAdjustable sampling rates ranging from 200 Hz up to 5 kHz to match dynamic machine cycles.\u003c\/li\u003e\n  \u003cli\u003eDirect integration into EtherCAT networks via dual shielded M8 screw-type interfaces.\u003c\/li\u003e\n  \u003cli\u003eRobust IP65, IP66, and IP67 protection ratings for direct machine mounting without an enclosure.\u003c\/li\u003e\n  \u003cli\u003eExtended configuration capabilities including programmable digital filter functions and tilt measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStructural health monitoring for wind turbines, bridges, and industrial towers.\u003c\/li\u003e\n  \u003cli\u003eVibration analysis and preventative maintenance on rotating machinery and drives.\u003c\/li\u003e\n  \u003cli\u003eTilt and orientation detection in material handling systems and heavy industrial cranes.\u003c\/li\u003e\n  \u003cli\u003eDynamic acceleration measurements in assembly line conveyor systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEP3752-0000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x 3-axis internal accelerometer sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e±2 to 16 g (programmable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200 Hz to 5 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 bit (including sign)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (from Us)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIP Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApprovals and Markings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnector Description\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Port In\u003c\/td\u003e\n      \u003ctd\u003eM8 female socket, 4-pin, shielded\u003c\/td\u003e\n      \u003ctd\u003eInput EtherCAT communication bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Port Out\u003c\/td\u003e\n      \u003ctd\u003eM8 female socket, 4-pin, shielded\u003c\/td\u003e\n      \u003ctd\u003eOutput \/ Downstream EtherCAT communication bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower In (Feed)\u003c\/td\u003e\n      \u003ctd\u003eM8 male plug, 4-pin\u003c\/td\u003e\n      \u003ctd\u003e24 V DC Control voltage supply (Us)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Out (Downstream)\u003c\/td\u003e\n      \u003ctd\u003eM8 female socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePower daisy-chain feed to subsequent modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module directly onto a flat mechanical surface using the integrated mounting holes. Variable installation positions are supported.\u003c\/li\u003e\n  \u003cli\u003eEnsure that all unused M8 connections are sealed with protective caps to maintain the IP65\/66\/67 environmental protection rating.\u003c\/li\u003e\n  \u003cli\u003eUse only shielded, industrial-grade M8 cables for communication connections to prevent electromagnetic interference from affecting signal resolution.\u003c\/li\u003e\n  \u003cli\u003eMaintain clear power separation and verify that the feed current does not exceed the maximum carrying capacity of the M8 power connectors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106508071275,"sku":"EP3752-0000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ep3752-0000-qkaocbmzjsq.png?v=1776244675","url":"https:\/\/www.plcprotech.com\/ms\/products\/beckhoff-ep3752-0000-ethercat-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}