{"product_id":"beckhoff-ip1002-b200-fieldbus-box-8-channel-digital-input-module","title":"Beckhoff IP1002-B200 Fieldbus Box 8-channel Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDecentralized signal acquisition in demanding industrial environments is managed directly at the machine level using the \u003cstrong\u003eBeckhoff IP1002-B200\u003c\/strong\u003e. This IP67-rated Fieldbus Box functions as an 8-channel digital input module designed to interface via the high-speed, noise-immune \u003cstrong\u003eLightbus\u003c\/strong\u003e fiber-optic ring network. Operating at a nominal voltage of \u003cstrong\u003e24 V DC\u003c\/strong\u003e and featuring a hardware-defined \u003cstrong\u003e3 ms input filter\u003c\/strong\u003e delay, this module ensures reliable signal transmission from proximity sensors, limit switches, and photoelectric eyes without requiring a protective electrical enclosure.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Performance Lightbus Interface:\u003c\/strong\u003e Optical fiber physical layer provides absolute immunity to electromagnetic interference (EMI) and lightning transients.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8 Digital Inputs:\u003c\/strong\u003e Accommodates standard 24 V DC sensors with robust signal logic levels conforming to industrial standard thresholds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Enclosure:\u003c\/strong\u003e Fully encapsulated IP67-rated housing protects internal electronics against moisture, dust, coolants, and mechanical impacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard M12 Connections:\u003c\/strong\u003e Standardized screw-type sensor connectors prevent vibration-induced loosening in high-vibration machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly Lines:\u003c\/strong\u003e Fiber-optic communication eliminates data corruption caused by heavy welding field interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConveyor and Material Handling:\u003c\/strong\u003e Localized sensor grouping directly on long-distance conveyor runs without localized junction boxes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging and Food Processing:\u003c\/strong\u003e Sealed encapsulation allows direct washdown mounting near actuators and sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP1002-B200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFieldbus System\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLightbus (Optical Fiber)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNumber of Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8 digital inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNominal Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Filter Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3.0 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSensor Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eM12 (screw type)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP67\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 degC to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-25 degC to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold; width: 30%;\"\u003eM12 Connector Pin\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSignal Assignment \/ Function\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e+24 V DC Sensor Supply (US)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNo Connection (NC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eGND (GNDs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eInput Signal (Channels 1 to 8 respectively)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFunctional Earth (FE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP1002-B200 module is standardly compatible with existing Lightbus optical ring controllers. While physical installation sizes are consistent across the IP1000 and IP1002 series, check your master controller's TwinCAT system configuration file (TSD\/XML) to ensure the proper addressing offsets are applied when migrating legacy modules to the newer IP1002-B200 hardware revision.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eSince Lightbus depends entirely on optical transmission, the routing of the plastic optical fiber (POF) lines is critical. Standard POF cables connected to the IP1002-B200 require a minimum bend radius of 30 mm. Exceeding this bend limit or applying excessive tensile force will cause permanent structural damage to the PMMA fiber core, resulting in immediate Lightbus ring communication failure (indicated by red status LEDs on the diagnostic panel).\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo secure the IP67 sealing rating of the M12 connector points, tighten all sensor cables to a exact torque threshold of 0.6 Nm. Always seal unassigned M12 channels with official IP67 protective screw caps. Utilizing hand-tightened or standard un-torqued connections will compromise the protective boundary, allowing coolant ingress and tracking faults inside the connection channels.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: ELECTRICAL HAZARD\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all 24 V DC system power sources and disconnect control loops prior to attaching or detaching any Fieldbus Box connections. Fiber-optic transmitters emit non-visible light; avoid looking directly into open optical transceiver channels or disconnected fiber interfaces during system diagnostic checks.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePosition the IP1002-B200 onto a flat, vibration-damped machine frame or specialized mounting rails, utilizing the two built-in mounting pass-through holes. Tighten fasteners to 1.2 Nm.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eExpose the Lightbus optical connection interfaces and insert the plastic optical fiber connectors, listening for a tactile click that denotes secure lock engagement.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePlug in the M12 industrial sensors to the labeled input channels and secure the threaded locking rings using a torque screwdriver rated for 0.6 Nm.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eEnergize the 24 V DC supply loop and verify that the diagnostic status LEDs exhibit solid green indicators, confirming correct Lightbus optical frame registration.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106460131691,"sku":"IP1002-B200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1002-b200-kixv3qa3pzd.png?v=1776244870","url":"https:\/\/www.plcprotech.com\/ms\/products\/beckhoff-ip1002-b200-fieldbus-box-8-channel-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}