{"product_id":"beckhoff-ip1002-b400-fieldbus-box-digital-input-module","title":"BECKHOFF IP1002-B400 Fieldbus Box Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Beckhoff \u003cstrong\u003eIP1002-B400\u003c\/strong\u003e is an industrial-grade, 8-channel digital input module designed for direct integration within Interbus fieldbus networks. This ruggedized extension module facilitates the high-speed acquisition of binary control signals from sensors and other discrete field devices, transmitting them reliably to the supervisory automation system. Engineered to withstand harsh manufacturing conditions, the device operates without an additional protective control cabinet, optimizing space and reducing wiring overhead across localized machine installations.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with industry-standard M12 connection interfaces, the \u003cstrong\u003eIP1002-B400\u003c\/strong\u003e ensures secure, vibration-resistant electrical connections. The integration of a 3 ms input filter prevents signal chatter and optimizes high-speed processing, making this Fieldbus Box a robust component for decentralized modern industrial automation systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 8 digital input channels for comprehensive local signal acquisition.\u003c\/li\u003e\n  \u003cli\u003eFeatures an Interbus communication interface for high-speed fieldbus synchronization.\u003c\/li\u003e\n  \u003cli\u003eUtilizes reliable M12 screw connectors to guarantee tight, IP-rated industrial connections.\u003c\/li\u003e\n  \u003cli\u003eIntegrates a 3 ms input filter to suppress electrical noise and signal bouncing.\u003c\/li\u003e\n  \u003cli\u003eRobust, compact mechanical design suitable for decentralized, cabinet-free mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly lines and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging and material handling machinery.\u003c\/li\u003e\n  \u003cli\u003eDecentralized process signal gathering in heavy industrial plants.\u003c\/li\u003e\n  \u003cli\u003eMachine-mount sensor integration with high mechanical stress profiles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP1002-B400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box Extension Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInterbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 digital inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 screw-type connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEstimated Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor correct operational performance and to preserve the protective rating, install the device according to these engineering practices:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Screw the module directly onto a flat, stable machine surface using the integrated mounting holes. Ensure the mounting plane is free of severe vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Hand-tighten all M12 connectors and then torque to the manufacturer-specified value using an appropriate torque wrench to preserve the environmental seal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the mounting surface or separate ground strap is connected to the functional earth ground of the system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Avoid routing signal and fieldbus lines parallel to high-voltage or high-current power cables to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106452857195,"sku":"IP1002-B400","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1002-b400-03qm142qg4x.png?v=1776244873","url":"https:\/\/www.plcprotech.com\/ms\/products\/beckhoff-ip1002-b400-fieldbus-box-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}