{"product_id":"beckhoff-ip2321-b730-fieldbus-box","title":"BECKHOFF IP2321-B730 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for direct installation in decentralized industrial environments, the \u003cstrong\u003eIP2321-B730\u003c\/strong\u003e fieldbus module enables robust communication and signal routing without the need for an additional control cabinet. This high-durability \u003cstrong\u003eBECKHOFF Fieldbus Box\u003c\/strong\u003e provides an integrated interface combining four digital inputs and four digital outputs to connect sensors and actuators directly on-site.\u003c\/p\u003e\n\n\u003cp\u003eOperating over the Modbus protocol, the module handles local processing demands through its specialized 3 ms input filters and robust 2 A output configurations. By reducing wiring overhead and simplifying connection paths, this module optimizes fieldbus network design and enhances signal integrity in standard automated environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect integration of four 24 V DC digital inputs and four 24 V DC digital outputs.\u003c\/li\u003e\n  \u003cli\u003eCommunication via standard Modbus RTU\/ASCII protocol.\u003c\/li\u003e\n  \u003cli\u003eRugged IP67 protection rating for harsh, cabinet-free environments.\u003c\/li\u003e\n  \u003cli\u003eM8 connection technology designed for rapid and secure sensor\/actuator cabling.\u003c\/li\u003e\n  \u003cli\u003eHigh-current output handling up to 2 A per digital channel.\u003c\/li\u003e\n  \u003cli\u003eFast, reliable input processing with a integrated 3 ms hardware filter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized manufacturing automation systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor lines requiring direct on-machine sensor interfaces.\u003c\/li\u003e\n  \u003cli\u003eHeavy industrial machinery requiring high-current digital output controls.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly operations with high exposure to dust, moisture, and vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP2321-B730\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eModbus RTU \/ Modbus ASCII\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 channels (24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 channels (24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 A per channel (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Connection Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 circular connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the Fieldbus Box, secure the housing directly to the machine frame using standard mounting screws. Ensure the mounting surface is even to prevent physical stress on the casing. Utilize high-quality, shielded Modbus and power cables to avoid electromagnetic interference. For optimal safety and noise immunity, establish a low-impedance ground connection between the module mounting tabs and the machine frame ground.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106475172203,"sku":"IP2321-B730","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2321-b730-u2b2xwzmlef.png?v=1776245046","url":"https:\/\/www.plcprotech.com\/ms\/products\/beckhoff-ip2321-b730-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}