{"product_id":"bently-nevada-136711-02-3500-61-rtd-tc-i-o-module-with-internal-barriers-and-internal-terminations","title":"Bently Nevada 136711-02 3500\/61 RTD\/TC I\/O Module with Internal Barriers and Internal Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e is a non-isolated RTD\/TC I\/O module with internal barriers and internal terminations designed for processing temperature transducer inputs within the 3500 Machinery Protection System. Installed in a full-height rear slot directly behind the 3500\/61 Temperature Monitor main module, it accepts input signals from up to six Resistance Temperature Detector (RTD) or Thermocouple (TC) transducers. The \u003cstrong\u003e136711-02\u003c\/strong\u003e channels conditioned signals and +4 to +20 mA proportional recorder outputs through integrated internal barriers to support intrinsically safe machinery monitoring applications in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides internal zener barriers and internal termination wiring connectors for six input channels\u003c\/li\u003e\n\u003cli\u003eInterface options configurable for 3-wire RTD, 4-wire RTD, and Thermocouple transducers\u003c\/li\u003e\n\u003cli\u003eIntegrates directly behind the 3500\/61 Temperature Monitor via the 3500 system backplane\u003c\/li\u003e\n\u003cli\u003eRoutes +4 to +20 mA proportional recorder outputs for each individual channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBearing temperature monitoring in rotating machinery such as turbines, compressors, and pumps\u003c\/li\u003e\n\u003cli\u003eProcess temperature measurement using RTD and TC transducers in hazardous location areas\u003c\/li\u003e\n\u003cli\u003eMachinery protection and condition monitoring within the 3500 system architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e136711-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Main Module\u003c\/td\u003e\n\u003ctd\u003e3500\/61 Temperature Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRTD\/TC Non-Isolated I\/O Module with Internal Barriers and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 6 RTD or TC transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 Mohm for each lead input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eType E (-100 degC to +1000 degC), Type J (0 degC to +760 degC), Type K (0 degC to +1370 degC), Type T (-160 degC to +400 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Types\u003c\/td\u003e\n\u003ctd\u003e100 ohm 3-wire \u0026amp; 4-wire platinum (alpha = 0.00385 or 0.00392), 120 ohm 3-wire \u0026amp; 4-wire nickel, 10 ohm 3-wire \u0026amp; 4-wire copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source Value\u003c\/td\u003e\n\u003ctd\u003e925 +-15 uA at 25 degC per transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA proportional to monitor full-scale (individual per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Compliance (Current Output)\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc range across load (0 to 600 ohm load resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output Resolution\u003c\/td\u003e\n\u003ctd\u003e0.3662 uA per bit +-0.15% error at room temperature (+-0.4% error over temperature range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the I\/O module in a single full-height rear slot positioned directly behind the corresponding 3500\/61 Temperature Monitor module.\u003c\/li\u003e\n\u003cli\u003eSecure wiring connections to the green and blue internal termination connector headers according to transducer type wiring configurations.\u003c\/li\u003e\n\u003cli\u003eEnsure operating ambient temperatures remain within the designated limit of 0 degC to +65 degC when internal barriers are active.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification \/ Standard\u003c\/th\u003e\n\u003cth\u003eStandard \/ Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Directive\u003c\/td\u003e\n\u003ctd\u003e2004\/108\/EC (EN 61000-6-2, EN 55011\/CISPR 11, EN 61000-6-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Voltage Directive\u003c\/td\u003e\n\u003ctd\u003e2006\/95\/EC (EN 61010-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Hazardous Area Approval\u003c\/td\u003e\n\u003ctd\u003eEx nC [ia] IIC: Class I, Div 1; AEx nC [ia] IIC: Class 1, Zone 2\/0 Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Approval\u003c\/td\u003e\n\u003ctd\u003eII 3\/(1) G, Ex nC[ia Ga] IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrazil Approval (3500\/61 only)\u003c\/td\u003e\n\u003ctd\u003eBR-Ex nC[nL] IIC T4, T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSouth Africa Approval\u003c\/td\u003e\n\u003ctd\u003eEx nCAL [ia] IIC T4, Ex nCAL [L] IIC T4, T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867319147,"sku":"136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-136711-02-internal-barriers-ira3aicimyi_32129713-62e8-4d9f-b345-fc759ea1af04.jpg?v=1765449500","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-136711-02-3500-61-rtd-tc-i-o-module-with-internal-barriers-and-internal-terminations","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}