{"product_id":"bently-nevada-330101-00-18-10-12-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-18-10-12-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-18-10-12-00\u003c\/strong\u003e is an unarmored \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e belonging to the 3300 XL 8 mm Proximity Transducer System. This specific configuration features an unthreaded length of 0.0 inches (fully threaded), an overall case length of 1.8 inches, and a total length of 1.0 meter (3.3 feet). It is equipped with a miniature coaxial ClickLoc connector and is designed with a specialty FluidLoc cable (Option 12), which provides robust oil and moisture sealing along the cable length to prevent fluid migration. This variant is ordered without hazardous area agency approvals (Option 00), offering a specialized, cost-effective solution for non-hazardous heavy industrial machinery applications.\u003c\/p\u003e\n\u003cp\u003eUsing the physical principle of eddy-current measurement, the probe enables continuous, non-contact measurement of static (shaft position) and dynamic (shaft vibration) displacement. It is ideal for monitoring radial vibration, axial position, and keyphasor reference inputs on high-speed rotating machinery like steam turbines, gas turbines, compressors, and large pumps, ensuring critical machinery protection and preventing costly unplanned outages.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFeaturing an 8 mm tip diameter for standard high-resolution eddy-current displacement measurement\u003c\/li\u003e\n  \u003cli\u003eSpecially designed with FluidLoc cable (Option 12) that prevents oil, moisture, or gas leakage through the internal strands of the cable\u003c\/li\u003e\n  \u003cli\u003eFully threaded case (0.0 in unthreaded length) with a 1.8 in overall case length utilizing a 3\/8-24 UNF thread design without armor\u003c\/li\u003e\n  \u003cli\u003eEquipped with a miniature gold-plated ClickLoc coaxial connector for low-attenuation signal transmission\u003c\/li\u003e\n  \u003cli\u003eProvides dependable non-contact vibration and shaft position measurements in critical rotating machinery\u003c\/li\u003e\n  \u003cli\u003eSealed differential pressure barrier between the probe tip and case using a Viton O-ring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-18-10-12-00 is primarily utilized in heavy industrial environments where monitoring rotating machinery shafts is essential and fluid leakage through cabling must be prevented. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine and gas turbine shaft vibration monitoring and axial displacement tracking\u003c\/li\u003e\n  \u003cli\u003eCompressor and high-pressure pump rotor displacement measurement\u003c\/li\u003e\n  \u003cli\u003eFluid-film bearing performance monitoring in power plants and petrochemical facilities\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery where oil-mist or cooling liquids are present and could migrate along standard cables\u003c\/li\u003e\n  \u003cli\u003eGeneral-purpose rotating machine protection systems where hazardous area certifications are not required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-18-10-12-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18\u003c\/td\u003e\n      \u003ctd\u003e1.8 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required \/ standard general-purpose configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-18-10-12-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF thread, unarmored\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.8 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc specialty cable (prevents internal fluid migration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance (R_PROBE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 +\/- 0.50 ohms (between center and outer conductor for 1.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Seal Temperature Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-34 degC (-30 degF) to prevent pressure seal degradation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSealing Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal between probe tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure high measurement accuracy and long-term reliability when installing the Bently Nevada 330101-00-18-10-12-00 proximity probe, follow these engineering recommendations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the probe with the appropriate probe gap as specified during system calibration (typically around 1.27 mm or 50 mils for a 200 mV\/mil system) against an AISI 4140 steel target.\u003c\/li\u003e\n  \u003cli\u003eEnsure that probe case thread engagement does not exceed 0.563 inches (14.3 mm) to avoid binding during installation.\u003c\/li\u003e\n  \u003cli\u003eAlways route the probe cable using proper shielding, mechanical protective conduits, and ground them correctly at the monitor end in accordance with local vibration monitoring installation standards.\u003c\/li\u003e\n  \u003cli\u003eDo not expose the probe's pressure-sealing Viton O-ring to temperatures below -34 degC (-30 degF), as extreme cold can cause sealing integrity loss.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666732970347,"sku":"330101-00-18-10-12-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-18-10-12-00-3300-xl-8-mm-proximity-probes-rwrg4e2hmao_8a79a556-05cf-458a-96d9-08330594c9f1.jpg?v=1765446715","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330101-00-18-10-12-00-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}