{"product_id":"bently-nevada-330104-00-18-10-01-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330104-00-18-10-01-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFully threaded metric M10 x 1 probe body (Option 00 unthreaded length) featuring an integrated AISI 302 or 304 stainless steel protective armor jacket over a 1.0-meter cable defines the \u003cstrong\u003e330104-00-18-10-01-00\u003c\/strong\u003e \u003cstrong\u003eproximity probe\u003c\/strong\u003e configuration. This mechanical setup is engineered to resist severe wear, making it suitable for applications where unarmored cables would be exposed to mechanical damage, abrasion, or fluid contamination in industrial machines.\u003c\/p\u003e\n\u003cp\u003eThis configuration is characterized by an overall case length of 180 mm (Option 18) and a total length of 1.0 meter (Option 10). Unlike variants without physical protection, the armor jacket safeguards the triaxial coaxial cable. It is supplied with a miniature coaxial ClickLoc connector and a pre-installed connector protector (Option 01), and does not require agency approvals (Option 00). It connects to a compatible 3300 XL extension cable and Proximitor sensor as part of a complete non-contacting displacement measurement chain.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 specifies a 0 mm unthreaded length, making the M10 x 1 metric probe case fully threaded for maximum mounting flexibility.\u003c\/li\u003e\n  \u003cli\u003eOption 18 provides an overall case length of 180 mm with standard metric M10 x 1 threads.\u003c\/li\u003e\n  \u003cli\u003eOption 10 sets a total probe length of 1.0 meter (3.3 feet) for the physical transducer connection.\u003c\/li\u003e\n  \u003cli\u003eOption 01 supplies a miniature coaxial ClickLoc connector with an integrated fluorosilicone connector protector over standard cable.\u003c\/li\u003e\n  \u003cli\u003eOption 00 designates that agency approvals are not required for this configuration.\u003c\/li\u003e\n  \u003cli\u003eAISI 302 or 304 stainless steel armor with an outer FEP jacket shields the cable against cutting, abrasion, and fluid ingress.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) tip material resists chemical degradation and high temperatures in harsh machinery environments.\u003c\/li\u003e\n  \u003cli\u003e8.0 mm tip diameter provides a linear range of 2.0 mm (80 mils) when paired with a matching 3300 XL Proximitor sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used in machinery protection and condition monitoring systems. Typical installations include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on industrial steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eRadial vibration monitoring of high-speed fluid-film bearing shafts in centrifugal compressors and pumps.\u003c\/li\u003e\n  \u003cli\u003eExpansion and casing measurements on large utility generators and electric motors.\u003c\/li\u003e\n  \u003cli\u003eSpeed and phase reference (Keyphasor) sensing on critical rotating machinery assets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330104-00-18-10-01-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe, M10 x 1 thread, with protective armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e18\u003c\/td\u003e\n      \u003ctd\u003e180 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330104-00-18-10-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer System\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003eMetric M10 x 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMechanical Armor\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 or 304 stainless steel with FEP jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Case Length\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd\u003e180 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Probe Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n      \u003ctd\u003eNot required (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Construction\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, FEP insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength Limit\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), begins at 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAverage Scale Factor\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePressure Sealing\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring differential pressure seal between tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApproximate Weight\u003c\/td\u003e\n      \u003ctd\u003e0.15 kg (150 g)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd\u003e220 mm x 220 mm x 35 mm (H x W x D) [Coiled configuration]\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Interface\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCenter Conductor\u003c\/td\u003e\n      \u003ctd\u003eSignal path for eddy-current driver circuit and transducer output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Shield\u003c\/td\u003e\n      \u003ctd\u003eReturn ground path and electrical shielding shield\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector with integrated protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nProper physical installation of the proximity probe is critical for correct measurements. Follow these field guidelines:\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Gap Setting:\u003c\/strong\u003e Position the probe to a typical gap of approximately 1.27 mm (50 mils) to achieve a nominal -9 Vdc output for radial vibration or midpoint axial position.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Torque:\u003c\/strong\u003e Secure the metric M10 x 1 probe case using the standard lock nut. Do not exceed the maximum rated installation torque of 22.6 N-m (200 in-lbf).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Bend Radius:\u003c\/strong\u003e Ensure the armored cable is routed with a bend radius of no less than 25.4 mm (1.0 in) to prevent internal triaxial conductor fatigue.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Connection:\u003c\/strong\u003e The miniature coaxial ClickLoc connector is a gold-plated \"click\" type. Connect the probe to the extension cable finger-tight. Ensure the fluorosilicone connector protector is properly installed to prevent moisture ingress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Routing:\u003c\/strong\u003e Route the armored cable through conduit or cable trays to protect it from high-velocity debris or extreme mechanical strain.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666734018923,"sku":"330104-00-18-10-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330104-00-18-10-01-00-3300-xl-8-mm-proximity-probes-b5sszmnf13y_4ff13b6e-8a31-484f-b60a-59effc96828c.jpg?v=1765446739","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330104-00-18-10-01-00-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}