{"product_id":"bently-nevada-330130-080-13-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-080-13-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 080 (8.0 m cable length) and Option 13 (armored FluidLoc cable with connector protector) specify this 3300 XL extension cable configuration - \u003cstrong\u003e330130-080-13-05\u003c\/strong\u003e. This \u003cstrong\u003e3300 XL standard extension cable\u003c\/strong\u003e connects a 3300 XL 8 mm proximity probe to a 3300 XL Proximitor sensor, facilitating eddy-current displacement measurements in industrial environments. The integrated FluidLoc technology prevents oil and other lubricants from leaking through the cable interior, making it suitable for pressurized or fluid-filled machine casings.\u003c\/p\u003e\n\u003cp\u003eCompared to unarmored standard cable variants, this model features heavy-duty stainless steel armor with an outer jacket, offering mechanical protection against abrasion, crushing, and physical impacts. The built-in fluorosilicone connector protectors provide environmental sealing at the connections, safeguarding against moisture and contaminant ingress. This configuration also features Option 05 hazardous area approval, certifying it for use in intrinsically safe environments with ATEX, IECEx, and CSA standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 080 provides an exact 8.0-meter cable length, forming a calibrated 9-meter system when paired with a 1.0-meter proximity probe.\u003c\/li\u003e\n\u003cli\u003eOption 13 specifies armored FluidLoc construction, preventing inner-cable fluid migration while offering heavy-duty physical armor.\u003c\/li\u003e\n\u003cli\u003eIntegrated fluorosilicone connector protectors seal the gold-plated ClickLoc connectors against fluids and contamination.\u003c\/li\u003e\n\u003cli\u003eOption 05 approval package certifies the transducer system for intrinsically safe and non-incendive environments.\u003c\/li\u003e\n\u003cli\u003ePatented CableLoc design provides 330 N tensile strength to prevent cable separation at the joints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed primarily in industrial machinery protection and condition monitoring setups, such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine shaft vibration and axial position measurement.\u003c\/li\u003e\n\u003cli\u003eCompressor and pump casing penetration points where oil containment is vital.\u003c\/li\u003e\n\u003cli\u003ePetrochemical and power generation environments requiring ATEX, IECEx, or CSA hazardous area zone ratings.\u003c\/li\u003e\n\u003cli\u003eAggressive mechanical environments requiring robust armored shielding against physical wear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Selected Option\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330130-080-13-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable, Armored FluidLoc with Connector Protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Connector Protector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals (Intrinsically Safe \/ Non-Incendive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330130-080-13-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc triaxial FEP insulated cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 or 304 stainless steel with FEP outer jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutside Cable Diameter (FluidLoc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.67 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Ferrule Max Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protector Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.4 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature coaxial ClickLoc connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFinger tight (audible click)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore DC Resistance (R_CORE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.76 +\/- 0.26 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket DC Resistance (R_JACKET)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 +\/- 0.11 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 N at cable-to-connector joints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mm x 250 mm x 50 mm (H x W x D) (Coiled shipping profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish a proper installation for the 3300 XL Standard Extension Cable, observe the following engineering guidelines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the combined length of the extension cable and proximity probe matches the total calibrated length of the Proximitor sensor (e.g., an 8.0 m extension cable requires a 1.0 m probe for a 9.0 m system).\u003c\/li\u003e\n\u003cli\u003eObserve the minimum bend radius limit of 25.4 mm to prevent inner-core conductor fatigue or signal degradation.\u003c\/li\u003e\n\u003cli\u003ePrior to mating, inspect the gold-plated coaxial ClickLoc connectors for cleanliness. Tighten the connectors only by hand until they audibly \"click\" into position.\u003c\/li\u003e\n\u003cli\u003eSlide the fluorosilicone connector protectors fully over the junction to ensure complete environmental sealing against water, process chemicals, and particulate matter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals (Option 05)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Intrinsically Safe (Ex ia) and Non-Incendive (Ex nA\/ec) certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T5...T1 Ga, Ex ia IIIC T90C...T280C Dc, Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with European Community Directive 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with European Community Directive 2011\/65\/EU and China RoHS (15-year EFUP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 2 (HFT = 0), SIL 3 (HFT = 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666538099051,"sku":"330130-080-13-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-080-13-05-extension-cable-dy300r4i41d_42021568-935f-4ede-8220-b79e9b04c098.jpg?v=1765440436","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330130-080-13-05-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}