{"product_id":"bently-nevada-330703-020-110-10-01-05-3300-xl-11-mm-proximity-probe","title":"Probe Proximity Bently Nevada 330703-020-110-10-01-05 3300 XL 11 mm","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330703-020-110-10-01-05\u003c\/strong\u003e specifies this \u003cstrong\u003e3300 XL 11 mm proximity probe\u003c\/strong\u003e configuration, featuring an unarmored metric M14 x 1.5 thread with a 20 mm unthreaded length (Option 020) and a 110 mm overall case length (Option 110). This 1.0-meter probe (Option 10) is supplied with a standard coaxial cable terminated in a ClickLoc miniature coaxial connector with a pre-installed connector protector (Option 01) and carries multiple hazardous area approvals (Option 05).\u003c\/p\u003e\n\u003cp\u003eUsed for non-contact eddy-current displacement measurement within 3300 XL 11 mm monitoring chains, this proximity probe detects shaft vibration, axial position, and rotor displacement on critical rotating machinery. Unlike smaller 8 mm systems, the 11 mm sensor tip provides an extended 4.0 mm (160 mil) linear measurement range, which is critical for large turbine casings or application environments where mounting gaps are wider. The pre-installed connector protector prevents environmental contamination and fluid ingress at the extension cable connection, ensuring continuous measurement integrity in the presence of turbine lubricants and moisture.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMetric M14 x 1.5 threaded housing without protective steel armor.\u003c\/li\u003e\n  \u003cli\u003e20 mm unthreaded case section with 110 mm total case length for deep metric sleeve mounting.\u003c\/li\u003e\n  \u003cli\u003e1.0 meter (3.3 feet) total cable length.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector featuring a pre-installed protective sleeve.\u003c\/li\u003e\n  \u003cli\u003eStandard FEP-insulated 75 ohm triaxial cable.\u003c\/li\u003e\n  \u003cli\u003eExtended 4.0 mm (160 mil) linear measurement range for large rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eCompatible with the Bently Nevada 3300 XL 11 mm Proximitor Sensor (330780) and 330730 extension cables.\u003c\/li\u003e\n  \u003cli\u003eMultiple hazardous area certifications (Option 05) including CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAxial position and thrust displacement monitoring on industrial steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eRadial shaft vibration and casing relative displacement measurements in high-power compressors.\u003c\/li\u003e\n  \u003cli\u003eRotor position and thermal expansion tracking in critical rotating plant equipment.\u003c\/li\u003e\n  \u003cli\u003eSpeed and Keyphasor phase reference measurements on large-diameter machine shafts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment Description\u003c\/th\u003e\n      \u003cth\u003eOption Code\u003c\/th\u003e\n      \u003cth\u003eSpecification Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330703-020-110-10-01-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Probe, M14 x 1.5 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e020\u003c\/td\u003e\n      \u003ctd\u003e20 mm unthreaded length (metric configuration in 2 mm increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e110\u003c\/td\u003e\n      \u003ctd\u003e110 mm overall case length (metric configuration in 2 mm increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature ClickLoc coaxial connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703-020-110-10-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Threading\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM14 x 1.5 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored FEP jacket)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e110 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), begins at approximately 0.5 mm (20 mils) from target and spans from 0.5 to 4.5 mm (20 to 180 mils) (-1 to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtended Range (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 0.5 to 5.0 mm (20 to 200 mils) (-1 to -19 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% over the 4.0 mm linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.10 mm (+\/-4 mils) over the linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Material \/ Size Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel target, minimum 30.5 mm (1.2 in) diameter flat surface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMinimum 152 mm (6.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe dc Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.9 +\/-0.5 ohms (center to outer conductor for 1.0 m lead)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected; tested to IEC 68-2-3 damp heat\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Rated Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead; 270 N (60 lb) at probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Thread Installation Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e63.3 N-m (560 in-lb) rated; 21.1 N-m (187 in-lb) recommended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Adjustment:\u003c\/strong\u003e Adjust the probe gap during installation to 2.5 mm (100 mils), which yields an approximate -10 Vdc output voltage when used with a calibrated Proximitor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Tighten the M14 x 1.5 metric probe case to a recommended torque of 21.1 N-m (187 in-lb). Do not exceed the maximum rated installation torque of 63.3 N-m (560 in-lb) to avoid thread deformation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Route the triaxial FEP cable carefully, keeping the bend radius above 25.4 mm (1.0 in) to protect the internal conductor integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Verify that the pre-installed connector protector (Option 01) is fully engaged over the male-to-female connector junction to shield the contacts from process fluids, dust, and turbine lubricants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Isolation:\u003c\/strong\u003e Ensure probe and cable shields are kept isolated from structural ground except at the dedicated instrument common ground inside the monitor enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e Complies with European Union EMC Directive 2014\/30\/EU and is tested to standards EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Certifications (Option 05):\u003c\/strong\u003e CSA, ATEX, and IECEx approvals for use in intrinsically safe and non-incendive environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga; Ex ia IIIC T90degC...T280degC Dc (when installed with approved zener barriers or galvanic isolators per Bently Nevada installation drawings).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Sparking\/Non-Incendive:\u003c\/strong\u003e Ex nA IIC T5...T1 Gc; Ex ec IIC T5...T1 Gc (when installed per drawing 140979 in at least an IP54 enclosure).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEntity Parameters:\u003c\/strong\u003e Ui = -28 V, Ii = 140 mA, Pi = 0.91 W, Ci = 1.5 nF, Li = 610 uH.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU (RoHS) and holds a 15-year EFUP designation under China RoHS.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (Hardware Fault Tolerance HFT = 0), SIL 3 capable (HFT = 1).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666626441579,"sku":"330703-020-110-10-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330703-020-110-10-01-05-3300-xl-11-mm-proximity-probes-t4jmzlaoz0y_ed878547-c79b-472d-8314-c98a15242dd8.jpg?v=1765444340","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330703-020-110-10-01-05-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}