{"product_id":"bently-nevada-330703-050-120-10-02-00-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330703-050-120-10-02-00 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 050 (50 mm unthreaded length), Option 120 (120 mm case length), and Option 02 (standard cable ClickLoc connector) specify this M14 x 1.5 metric proximity probe configuration — \u003cstrong\u003e330703-050-120-10-02-00\u003c\/strong\u003e. This non-contact eddy-current displacement sensor is designed for installation in 3300 XL 11 mm transducer systems, where it operates in conjunction with a 330780 Proximitor sensor and a 330730 extension cable. Operating without mechanical armor, the probe is equipped with a standard 75 ohm triaxial FEP-insulated lead cable that provides robust moisture and environmental protection.\u003c\/p\u003e\n\u003cp\u003eUnlike armored configurations (such as model 330704) or variants requiring extensive agency certifications (Option 05), this standard-mount metric probe provides a simplified installation for general-purpose, non-hazardous industrial areas. It yields a calibrated linear range of 4.0 mm (160 mils) with an incremental scale factor (ISF) of 3.94 V\/mm (100 mV\/mil), enabling highly precise displacement, vibration, and rotor position measurements on critical rotating machinery like compressors, steam turbines, and large industrial pumps.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMetric thread size of M14 x 1.5 without mechanical armor (base model 330703)\u003c\/li\u003e\n  \u003cli\u003eUnthreaded probe case length of 50 mm (Option 050)\u003c\/li\u003e\n  \u003cli\u003eOverall case length of 120 mm (Option 120)\u003c\/li\u003e\n  \u003cli\u003eTotal integrated cable length of 1.0 meter (3.3 feet) (Option 10)\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector on a standard FEP triaxial cable (Option 02)\u003c\/li\u003e\n  \u003cli\u003eGeneral industrial standard configuration with no agency approvals required (Option 00)\u003c\/li\u003e\n  \u003cli\u003eTight pressure sealing at the tip utilizing a built-in Viton O-ring\u003c\/li\u003e\n  \u003cli\u003ePre-drilled locknut supplied as standard with safety wire holes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine and centrifugal compressor shaft vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eRotor position and axial thrust displacement measurement\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems on 11 mm proximity probe loops\u003c\/li\u003e\n  \u003cli\u003eIndustrial rotating machinery diagnostics in non-hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703-050-120-10-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Probe, M14 x 1.5 metric thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAAA: Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e050\u003c\/td\u003e\n      \u003ctd\u003e50 mm unthreaded length (ordered in 2 mm increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBBB: Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120\u003c\/td\u003e\n      \u003ctd\u003e120 mm overall case length (ordered in 2 mm increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCC: Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDD: Connector and Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEE: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo agency approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330703-050-120-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Diameter\u003c\/td\u003e\n      \u003ctd\u003e11 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type and Size\u003c\/td\u003e\n      \u003ctd\u003eM14 x 1.5 metric thread (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e50 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd\u003e120 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Construction\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTarget Material Calibration\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel target (minimum diameter 31 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), begins at approx. 0.5 mm (20 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) plus\/minus 10%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than plus\/minus 0.10 mm (plus\/minus 4 mils) over standard range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe dc Resistance (1.0 m)\u003c\/td\u003e\n      \u003ctd\u003e5.9 plus\/minus 0.5 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Rated Case Torque\u003c\/td\u003e\n      \u003ctd\u003e63.3 N-m (560 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Case Torque\u003c\/td\u003e\n      \u003ctd\u003e21.1 N-m (187 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Cable Tension\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHumidity Resistance\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Component\u003c\/th\u003e\n      \u003cth\u003eTechnical Characteristics\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Outside Diameter\u003c\/td\u003e\n      \u003ctd\u003e7.23 mm maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eContact Plating\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass for low contact resistance and corrosion protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Compatibility\u003c\/td\u003e\n      \u003ctd\u003eMates directly with 3300 XL 11 mm Extension Cables (Model 330730)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo achieve the highest measurement accuracy and prevent mechanical binding, adhere to the following installation guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Thread Engagement:\u003c\/strong\u003e For M14 x 1.5 threaded cases, the maximum thread engagement is 21 mm. Exceeding this length may cause thread binding during installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e Maintain a minimum cable bend radius of 25.4 mm (1.0 in) for standard unarmored coaxial cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Use a fluorosilicone connector protector or self-fusing silicone tape on the probe-to-extension cable junction to shield against moisture, dust, and turbine oil ingress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Alignment:\u003c\/strong\u003e Ensure the probe is positioned over a target surface of AISI 4140 steel (or calibrated target material) with a recommended flat diameter of at least 30.5 mm (1.2 in).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e Secure the probe case using the standard locknuts. Tighten to a recommended torque of 21.1 N-m (187 in-lb) and do not exceed the maximum rated limit of 63.3 N-m (560 in-lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is manufactured to meet rigorous quality control standards and is compliant with general European industrial standards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU, satisfying requirements for EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestriction of Hazardous Substances (RoHS):\u003c\/strong\u003e Complies with RoHS Directive 2011\/65\/EU and is marked under China RoHS regulations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Sealing:\u003c\/strong\u003e Standard probe construction designed to seal differential pressure between the probe tip and case utilizing a built-in Viton O-ring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848182635,"sku":"330703-050-120-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330703-050-120-10-02-00-proximity-transducer-uxjqngcu4sq_90a8f71b-0c04-4a80-95c2-1b74ff82ffc2.jpg?v=1765448977","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330703-050-120-10-02-00-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}