{"product_id":"bently-nevada-330730-080-00-00-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-080-00-00 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330730-080-00-00\u003c\/strong\u003e: 3300 XL 11 mm extension cable, configured with an 8.0 m cable length (Option 080), standard unarmored coaxial cable (Option 00), and no agency approvals (Option 00). This cable connects a 3300 XL 11 mm proximity probe to a 3300 XL 11 mm Proximitor sensor, establishing the necessary physical and electrical path for non-contact eddy-current displacement measurement. The total system length (probe plus extension cable) must equal the calibration length of the Proximitor sensor, which is typically 9.0 m when pairing this 8.0 m cable with a 1.0 m probe.\u003c\/p\u003e\n\u003cp\u003eUnlike variants equipped with stainless steel armor (Option 01) or connector protectors (Option 02), this specific model utilizes standard unarmored FEP insulation. This provides a lightweight, highly flexible routing profile ideal for conduit runs and protected cable trays where mechanical abrasion and liquid submersion risks are minimal. The integrated gold-plated brass ClickLoc connectors prevent mechanical loosening under machinery vibration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8.0 Meter Cable Length:\u003c\/strong\u003e Specified by Option 080 to provide the exact physical reach needed to form 9.0 m total system lengths when paired with 1.0 m probes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard FEP Insulation:\u003c\/strong\u003e Fluoroethylene propylene (FEP) outer jacket offers high chemical and temperature resistance without the added weight and rigid bend radius of steel armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold-Plated ClickLoc Connectors:\u003c\/strong\u003e Gold-plated brass coaxial connectors lock securely to prevent accidental decoupling and maintain consistent electrical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e75 Ohm Impedance:\u003c\/strong\u003e Matches the impedance profile of 3300 XL 11 mm transducer systems to preserve signal integrity and avoid transmission reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Agency Approvals Required:\u003c\/strong\u003e Option 00 specifies a non-certified variant, simplifying installations in general purpose or non-hazardous plant locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation gas and steam turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial fans, pumps, and generators\u003c\/li\u003e\n\u003cli\u003eShaft radial vibration monitoring and axial thrust position measurement\u003c\/li\u003e\n\u003cli\u003eRetrofitting existing 11 mm non-contact transducer chains\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Selected Option\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330730-080-00-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330730-080-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard unarmored FEP jacketed coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance (R_core)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 +\/- 0.2 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Conductor Resistance (R_jacket)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 +\/- 0.5 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClickLoc miniature coaxial connectors (one male, one female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 N (60 lb) at probe lead to extension cable connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Connection Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFinger tight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Connection Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.565 N-m (5 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtension Cable Weight (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 g\/m (0.5 oz\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +177 degC (-62 to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the extension cable length (8.0 m) combined with the probe length (1.0 m) matches the calibrated length of the Proximitor sensor (9.0 m) for accurate calibration and linear range output. When routing the cable, avoid sharp bends and maintain a bend radius greater than 25.4 mm (1.0 in). Use insulated cable clamps or conduit to prevent the cable from chafing against metal structures. Tighten ClickLoc connectors to finger-tight status; do not exceed 0.565 N-m (5 in-lb) of torque. For humid or wet environments, the use of silicone tape or connector protectors is recommended at the probe-to-extension-cable connection to prevent moisture ingress (note: silicone tape is not recommended if exposed to turbine oil).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666857554283,"sku":"330730-080-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-080-00-00-extension-cable-yvshyhwkxxr_6121ead1-5c7e-47ce-b55d-8251e31e9eff.jpg?v=1765449216","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330730-080-00-00-3300-xl-11-mm-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}