{"product_id":"bently-nevada-330881-16-10-105-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-16-10-105-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-16-10-105-06-02\u003c\/strong\u003e specifies this metric PROXPAC XL proximity transducer assembly, featuring a 3300 XL 8 mm probe without approvals (Option 16), a 100 mm standoff adapter (Option 10), and a 105 mm probe penetration length (Option 105).\u003c\/p\u003e\n\u003cp\u003eThis integrated proximity transducer is housed in a molded thermoplastic assembly made of glass and conductive fiber-reinforced Polyphenylene Sulfide (PPS), which provides IP66 and Type 4X protection against harsh industrial environments. By incorporating the 3300 XL Proximitor sensor directly within the housing cover, this unit functions as a self-contained eddy-current measurement system that eliminates the need for separate Proximitor housings or intermediate extension cables. Field wiring connects directly to terminal blocks inside the enclosure, streamlining installation on rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 16 integrates a 3300 XL 8 mm proximity probe with a 1-meter cable length directly inside the protective sleeve.\u003c\/li\u003e\n  \u003cli\u003eOption 10 provides a 100 mm metric standoff adapter to adjust the probe's clearance from the target surface.\u003c\/li\u003e\n  \u003cli\u003eOption 105 defines a 105 mm probe sleeve penetration length, ordered in 1 mm increments.\u003c\/li\u003e\n  \u003cli\u003eOption 06 includes a fittings kit with one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two plugs for conduit connections.\u003c\/li\u003e\n  \u003cli\u003eOption 02 configures a 3\/4-14 NPT outer mounting thread, which is required for installations utilizing the standoff adapter.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene Sulfide (PPS) molded housing is strengthened with glass and conductive fibers to dissipate electrostatic charges and withstand severe environments.\u003c\/li\u003e\n  \u003cli\u003eEnclosure rated for IP66 and Type 4X to resist hose-directed water and environmental contaminants.\u003c\/li\u003e\n  \u003cli\u003eInternal terminal block allows direct field wiring to the vibration monitoring system, avoiding external extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eNon-contact proximity measurements in steam turbines, gas turbines, compressors, and pump systems.\u003c\/li\u003e\n  \u003cli\u003eSevere environmental installations requiring Type 4X and IP66 chemical or water protection.\u003c\/li\u003e\n  \u003cli\u003eSpace-constrained installations where a separate external Proximitor sensor housing is not practical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eOption Code on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-16-10-105-06-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e100 mm standoff adapter length (ordered in increments of 10 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e105\u003c\/td\u003e\n      \u003ctd\u003e105 mm probe sleeve penetration length (ordered in increments of 1 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required when ordering Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-16-10-105-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated eddy-current proximity probe and Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption (-23 Vdc to -26 Vdc with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 Ohm +\/- 0.50 Ohm (for 1.0 m probe cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target (approx. -1 Vdc to -17 Vdc output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error (measured over 80 mil range from 0 to +45 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/- 0.025 mm (+\/- 1 mil) at room temperature\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV output voltage change per volt of input change\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eO-ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGrounding Liner Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra soft cellular silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 (verified by BASEEFA report T07\/0709) and Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eImpact Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHousing withstands 4 Joule impacts at -39 degC and +115 degC (certified by BASEEFA); 7 Joule at room temperature (CSA verified)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Load Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHousing supports 912 N (205 lbf) cantilever load placed 38 mm from the unsupported end\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRetaining Nut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Sleeve Locknut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temp\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Operating Temp\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when properly sealed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish a proper environmental seal, verify that the housing cover and all conduit connection points are fully secure. Take precautions to prevent moisture from traveling through the conduit piping into the housing. Tighten the retaining nut to the recommended torque of 29.5 N-m (260 in-lb) and the probe sleeve locknut to 39.3 N-m (350 in-lb). Maintain the recommended gap setting of 1.27 mm (50 mils) between the probe tip and the target material during setup.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE compliant\u003c\/li\u003e\n  \u003cli\u003eFCC Part 15 compliant\u003c\/li\u003e\n  \u003cli\u003eEMC Directive 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666754433387,"sku":"330881-16-10-105-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-16-10-105-06-02-proxpac-xl-proximity-transducer-50gsszqqkcc_bdb0c789-bbda-4d25-a3cf-87439d0ef7a2.jpg?v=1765447023","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330881-16-10-105-06-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}