{"product_id":"bently-nevada-330881-28-00-100-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-00-100-06-02 PROXPAC XL Transduser Proksimit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 06 (one NPT fitting and reducer kit) define this metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly configuration — \u003cstrong\u003e330881-28-00-100-06-02\u003c\/strong\u003e. This integrated system combines a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor directly into a single, glass-reinforced polyphenylene sulfide (PPS) thermoplastic housing. By eliminating the typical extension cable between the probe and Proximitor, this configuration simplifies field wiring by routing connections directly from the monitor to the transducer assembly itself. The PPS material incorporates glass and conductive fibers to increase mechanical robustness and dissipate electrostatic charges, ensuring durable operation in demanding industrial areas.\u003c\/p\u003e\n\n\u003cp\u003eUnlike basic variants with unapproved sensors or different mechanical mounting configurations, this specific assembly includes a probe certified for multiple hazardous area approvals, a 100 mm probe penetration length, and a 3\/4-14 NPT mounting thread. It is designed for direct machinery casing mounting to monitor shaft vibration and axial position, with an integrated gland and plug kit (Option 06) to seal the field wiring entry.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 28 Probe with Multiple Approvals\u003c\/strong\u003e: Includes a 3300 XL 8 mm probe pre-installed and certified for hazardous environments under global standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Design\u003c\/strong\u003e: Places the Proximitor sensor directly inside the housing cover to eliminate the need for an external extension cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlass-reinforced PPS Thermoplastic\u003c\/strong\u003e: Features a conductive fiber-filled polyphenylene sulfide housing rated for Type 4X and IP66 environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 100 Penetration Depth\u003c\/strong\u003e: Provides a 100 mm probe penetration length for direct machinery casing installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 02 Mounting Thread\u003c\/strong\u003e: Features a 3\/4-14 NPT thread on the outer sleeve assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 06 Fittings Kit\u003c\/strong\u003e: Supplied with one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two plugs for cable entrance sealing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and axial position monitoring on large rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eDirect machinery casing installations requiring external adjustment of proximity probes.\u003c\/li\u003e\n  \u003cli\u003eCorrosive or humid environments where separate Proximitor housings and extension cables are prone to environmental degradation.\u003c\/li\u003e\n  \u003cli\u003eHazardous area industrial settings requiring certified intrinsically safe or non-incendive transducer loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-00-100-06-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100\u003c\/td\u003e\n      \u003ctd\u003e100 mm probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e330881-28-00-100-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer Type\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), begins at 0.25 mm (10 mils) from target (0.25 to 2.3 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% (including interchangeability error)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 m (1000 ft) of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Requirements\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption (-23 Vdc to -26 Vdc with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupply Sensitivity\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Sleeve \u0026amp; Retaining Screws\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n      \u003ctd\u003eNeoprene (Viton O-ring inside probe case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Housing Operating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Housing Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n      \u003ctd\u003eType 4X, IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Retaining Nut Torque\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Locknut Torque\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure the integrated PPS housing grounding liner and retaining plate are properly bonded to local machine casing ground to dissipate static charges effectively.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap\u003c\/strong\u003e: Gap the 3300 XL 8 mm probe at approximately 1.27 mm (50 mils) to establish center voltage within the 2.0 mm (80 mils) linear operating range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit and Moisture Seal\u003c\/strong\u003e: Use the provided Option 06 fittings (3\/4-14 NPT and 3\/4-14 NPT to 1 1\/2-14 NPT SST reducer) with proper thread sealant. Users must prevent moisture from traveling down the conduit into the housing by using a conduit seal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSleeve Installation\u003c\/strong\u003e: Tighten the outer sleeve locknut to a recommended torque of 39.3 N-m (350 in-lb) and the retaining nut to 29.5 N-m (260 in-lb) to prevent process leaks and ensure mechanical rigidity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResonance Prevention\u003c\/strong\u003e: For custom assemblies where combined standoff \"B\" and penetration \"C\" exceed 305 mm (12 inches), install additional sleeve supports to avoid vibrational resonance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe integrated transducer system complies with major global standards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark\u003c\/strong\u003e: Complies with applicable European Union directives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA (CNRTLUS)\u003c\/strong\u003e: Intrinsically Safe (Class I, Zone 0, Groups A, B, C, D) and Non-Incendive (Class I, Division 2, Groups A, B, C, D) installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx\u003c\/strong\u003e: Approved for hazardous areas with EPL Ga (Ex ia IIC T4\/T5 Ga) and EPL Gc (Ex nA\/ec IIC T4\/T5 Gc) ratings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e: Enclosure design is IP66 and Type 4X certified for severe industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666736509291,"sku":"330881-28-00-100-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-00-100-06-02-proxpac-xl-proximity-transducer-j3svcqmheg2_ee3b9d47-4714-41e5-b95b-0dceb43dffb5.jpg?v=1765446803","url":"https:\/\/www.plcprotech.com\/ms\/products\/bently-nevada-330881-28-00-100-06-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}